Moldex 7000 Series Half Mask Respirator 7001 7002 7003
Moldex 7000 Series Half Mask Respirator — 7001, 7002 & 7003 The Moldex 7000 Series Half Mask Respirator is a lightweight, comfortable reusable half mask built for all-day industrial wear. Its soft, dual-materia...
Check Price on Amazon🔒 Amazon Associate · You pay the same price · We earn a small commission
Moldex 7000 Series Half Mask Respirator — 7001, 7002 & 7003
The Moldex 7000 Series Half Mask Respirator is a lightweight, comfortable reusable half mask built for all-day industrial wear. Its soft, dual-material facepiece is made with no PVC, no natural rubber latex, and no silicone — a Moldex hallmark that helps avoid skin irritation and contact allergies. The low-profile design and large, downward-facing Ventex® exhalation valve push heat and moisture away from the face for a cooler, drier seal, while the SmartStrap® head harness adjusts and stays put without pinching. The 7000 facepiece twist-locks onto the full Moldex bayonet Smart® cartridge and filter library. Choose your size from the three models — the 7001 (Small), 7002 (Medium), and 7003 (Large) — using the size selector above.
- Type: Reusable half mask (half face) air-purifying respirator
- Models / Sizes: 7001 Small · 7002 Medium · 7003 Large
- Facepiece material: Soft dual-material seal — no PVC, no natural rubber latex, no silicone
- Valve: Ventex® exhalation valve — reduces heat and moisture buildup
- Harness: SmartStrap® adjustable head harness — easy on/off, low pressure
- NIOSH approval: 42 CFR Part 84 air-purifying half facepiece (with approved Moldex cartridges/filters)
- APF: 10 per OSHA 29 CFR 1910.134 Appendix A (use up to 10× the OEL)
- Cartridge connection: Moldex Smart® bayonet twist-lock — accepts all Moldex 7000-series Smart cartridges & filters
- Cartridges included: No — the facepiece is sold separately from filters/cartridges
- Reusable: Yes — clean and reuse the facepiece; replace cartridges as needed
7001 vs 7002 vs 7003 — Which Size?
The three 7000 Series models are the same respirator in three facepiece sizes — identical Ventex valve, SmartStrap harness, NIOSH approval, and Smart bayonet cartridges. Only the face-seal geometry changes, and a respirator only protects you if it seals. Choose your size from the selector above:
| Model | Size | Who it fits |
|---|---|---|
| Moldex 7001 | Small | Smaller facial profiles — many women and slighter builds |
| Moldex 7002 ← most common | Medium | Most adult workers — the default size and best starting point |
| Moldex 7003 | Large | Larger facial profiles — choose if Medium feels tight or gaps at the jaw |
Facial dimensions — not height or build — determine fit, and a beard or stubble crossing the seal breaks it regardless of size. OSHA 1910.134(f)(2) requires fit testing before workplace use; if Medium (7002) fails, try Small (7001) or Large (7003).
Best Uses for the Moldex 7000 Series
Paired with the right Moldex Smart cartridge or filter, the Moldex 7000 reusable respirator suits contractors, manufacturers, painters, and maintenance crews — match the cartridge to the hazard:
- Painting & solvents: a 7100 organic vapor cartridge for paint, adhesives, and solvent vapors — add a P100 prefilter for spray mist.
- Construction & silica dust: a 7940/7740 P100 filter for concrete dust and respirable crystalline silica.
- Acid gases: a 7200 acid gas cartridge for chlorine, hydrogen chloride, and sulfur dioxide.
- Solvents plus acid gas: a 7300 OV/acid gas combination cartridge.
- Ammonia work: a 7400 ammonia/methylamine cartridge for refrigeration and chemical handling.
- Mixed or unpredictable exposures: keep a 7600 multi-gas/vapor Smart cartridge on hand.
Moldex 7000 Compatible Cartridges & Filters
The 7000 facepiece uses the Moldex Smart® bayonet system — the same connection across the 7000 cartridge and filter line, and the same one used by the Moldex 9000 Series full facepiece. Match the cartridge to your hazard:
| Cartridge / Filter | Protection | Typical use |
|---|---|---|
| Moldex 7100 | Organic Vapor | Paint, solvents, adhesives |
| Moldex 7200 | Acid Gas | Chlorine, HCl, SO₂ |
| Moldex 7300 | Organic Vapor / Acid Gas | Solvents plus acid gases |
| Moldex 7400 | Ammonia / Methylamine | Refrigeration, chemical handling |
| Moldex 7600 | Multi-Gas / Vapor | Broad, mixed gas & vapor exposures |
| Moldex 7940 / 7740 | P100 particulate | Silica, dust, mold, lead, welding fume |
| Moldex 7760 | P100 + nuisance OV/AG | Particulate with light odor relief |
Browse the full lineup at Moldex Respirator Cartridges & Filters. Not sure which to pick? See How to Choose a Respirator Cartridge and Respirator Filter Types Explained. Note that cartridges are not interchangeable between brands — only Moldex Smart cartridges fit the 7000 facepiece (see Are Respirator Cartridges Universal?).
Why Choose the Moldex 7000?
Compared with other reusable half masks, the Moldex 7000 stands out for its latex-, PVC-, and silicone-free facepiece and its low-profile comfort. It is a strong choice for workers with skin sensitivities or anyone who wears a respirator for long stretches. Need a full-facepiece for eye protection too? Step up to the Moldex 9000 Series full face respirator, which shares the same Smart cartridges. Comparing brands and styles? See our Best Half Face Respirator guide, or browse the Moldex Half Mask Respirators and all half mask respirators.
OSHA & NIOSH Compliance
- NIOSH approved air-purifying half-facepiece respirator under 42 CFR Part 84 (with approved Moldex cartridges/filters).
- APF 10 per OSHA 29 CFR 1910.134 Appendix A — use up to 10× the Occupational Exposure Limit.
- Fit testing: OSHA 1910.134(f)(2) requires annual qualitative (QLFT) or quantitative (QNFT) fit testing before operational use and when changing facepiece size.
- User seal check: perform a positive- and negative-pressure seal check each time you don the respirator (Appendix B-1).
- Written program: required wherever respirators are used (1910.134(c)), including hazard assessment, medical evaluation (1910.134(e)), and a cartridge change-out schedule (1910.134(d)(3)(iii)).
- Not for IDLH or oxygen-deficient atmospheres.
Frequently Asked Questions
What is the difference between the 7001, 7002, and 7003?
Only facepiece size — Small (7001), Medium (7002), and Large (7003). All three share the same Ventex valve, SmartStrap harness, NIOSH approval, and Smart bayonet cartridges. Most adults fit the Medium; confirm with an OSHA fit test.
Which size Moldex 7000 should I buy?
Most adults fit the 7002 (Medium) — the right default if unsure. Choose 7001 (Small) for smaller faces or 7003 (Large) for larger faces, and confirm fit with an OSHA fit test.
What cartridges fit the Moldex 7000 Series?
All Moldex 7000-series Smart bayonet cartridges and filters — including the 7100 organic vapor, 7200 acid gas, 7300 OV/acid gas, 7400 ammonia/methylamine, 7600 multi-gas, and 7940/7740 P100 filters.
Is the Moldex 7000 NIOSH approved?
Yes — it is a NIOSH-approved half-facepiece air-purifying respirator under 42 CFR Part 84 when used with approved Moldex cartridges and filters.
Is the Moldex 7000 latex-free?
Yes — the facepiece is made with no natural rubber latex, no PVC, and no silicone, which helps avoid skin irritation and contact allergies during long wear.
Can the Moldex 7000 use P100 filters?
Yes — it accepts the 7940/7740 P100 particulate filter and the 7760 P100 with nuisance OV/acid gas relief, plus combination cartridges with a P100 built in.
Is the Moldex 7000 good for painting?
Yes — use a 7100 organic vapor cartridge for solvent and paint vapors, and add a P100 prefilter when spraying to capture mist.
Is the Moldex 7000 good for silica dust?
Yes — fit a 7940/7740 P100 filter for respirable crystalline silica from concrete cutting, grinding, and demolition (OSHA 1926.1153).
Are Moldex cartridges interchangeable with 3M or Honeywell?
No — respirator cartridges are brand- and series-specific. Only Moldex 7000-series Smart bayonet cartridges fit the 7000 facepiece. See Are Respirator Cartridges Universal?
APF 10 per OSHA 29 CFR 1910.134 Appendix A. No air-purifying respirator is appropriate in IDLH or oxygen-deficient atmospheres. This content is not medical, legal, or regulatory advice — respirator selection is governed by applicable OSHA standards and your facility's respiratory protection program.
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.