Honeywell North 75852P100L Mercury vapor and chlorine / P100 Cartridge β North Bayonet
EDITORIAL REVIEW: 4.5/5WC Safety Review β Honeywell North 75852P100L Mercury vapor and chlorine/P100 Cartridge Best For: mercury vapor and chlorine with dust β chlor-alkali, lab and remediation work β on North bay...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Best For: mercury vapor and chlorine with dust β chlor-alkali, lab and remediation work β on North bayonet respirators, with an end-of-service-life indicator for mercury.
Not For: organic vapor, ammonia or formaldehyde. It covers mercury vapor and chlorine and particulate only.
Bottom Line: the do-it-all cartridge for mercury vapor and chlorine plus dust on the North bayonet system. If you face mercury vapor and chlorine with no dust, the gas-only N75002L is a cheaper choice.
Editorial assessment by the WC Safety Editorial Team. Scoring reflects published Honeywell North specifications, NIOSH approval, application fit and category expertise. WC Safety did not laboratory-test this product.
CHECK PRICE ON AMAZON βSHOP NORTH CARTRIDGES β
As an Amazon Associate, WC Safety earns from qualifying purchases. Full affiliate disclosure.
Honeywell North 75852P100L Overview
The Honeywell North 75852P100L is a NIOSH-approved combination cartridge that snaps onto North bayonet half- and full-face respirators to protect against mercury vapor and chlorine AND airborne particulate in one unit. The built-in P100 filter captures at least 99.97% of particles, so the 75852P100L covers gas plus dust, mist and fume without a separate prefilter. Start with our guide to choosing a respirator cartridge and the Honeywell North cartridge guide, then confirm the markings on the respirator cartridge color chart.
The 75852P100L cartridge belongs to the Honeywell North respirator filters and cartridges family. Read our hands-on Honeywell North 75852P100L review for field-tested detail. Buy it when you face mercury vapor and chlorine together with dust; choose the gas-only N75002L if there is no particulate.
Where the 75852P100L Fits in Cartridge Selection
Confirm the hazards before the cartridge. The 75852P100L handles mercury vapor and chlorine and airborne particulate. If you are weighing gas-only versus combination cartridges, our organic vapor vs P100 guide and respirator filter types explained walk through when the integrated P100 is worth it.
Who Should Buy the 75852P100L?
Buy it if your work mixes mercury vapor and chlorine with dust or mist. Choose another cartridge if your hazard is different: pick the gas-only N75002L when there is no dust, or 7581P100L for organic vapor + P100, 7583P100L for OV/AG + P100 or 75SCP100L for multi-gas + P100.
What Does the 75852P100L Protect Against?
| Hazard | Fit | Buyer guidance |
|---|---|---|
| Mercury vapor and chlorine (mercury vapor and chlorine) | Yes | Gas side β the sorbent bed. |
| Dust, mist, fume, lead (particulate) | Yes β P100 | Built-in P100 filter, β₯99.97%, oil-proof. |
| Organic vapor, ammonia or formaldehyde | No | Use the 7583P100L or 75SCP100L for a broader gas mix. |
What the 75852P100L Does NOT Protect Against
The 75852P100L does not stop organic vapor, ammonia or formaldehyde; for a broader gas mix with P100 use the 75SCP100L, and for particulate alone the 7580P100 filter is enough.
No air-purifying cartridge makes a dangerous atmosphere safe. Never use the 75852P100L in an oxygen-deficient or IDLH (immediately dangerous to life or health) atmosphere, in unknown concentrations, or against gases with no warning properties β those conditions require a supplied-air or SCBA system, not a cartridge respirator.
Best Applications
Mercury handling & remediation
Mercury vapor and chlorine exposures with particulate are its core use; the ESLI window helps time mercury change-out. See our best respirator for chemical workers guide.
Chlor-alkali & lab work
Where chlorine and mercury vapor appear with dust, one cartridge covers it. Match the band on the cartridge color chart.
Pros & Cons
mercury vapor and chlorine + P100 in one cartridge Β· β₯99.97% oil-proof particulate Β· no separate prefilter to add Β· fits the full North bayonet range
one gas class only on the gas side Β· costs more than the gas-only N75002L Β· North bayonet only (not 3M or MSA)
75852P100L vs Other North Cartridges
| Cartridge | Protects against |
|---|---|
| N75002L | Acid gas (no P100) |
| 7582P100L | Acid gas + P100 |
| 75SCP100L | Multi-gas + P100 |
| 7580P100 | P100 only |
75852P100L vs the Alternatives
How it stacks up against the closest North options:
- 75852P100L vs 7582P100L: the 75852P100L adds mercury vapor and an ESLI; the 7582P100L is acid gas + P100 without mercury.
- 75852P100L vs 75SCP100L: the 75852P100L is the mercury/chlorine specialist; the 75SCP100L is a broad gas mix without mercury.
- 75852P100L vs 7580P100: the 7580P100 is particulate only; the 75852P100L adds mercury vapor and chlorine.
75852P100L Quick Answers
Does the 75852P100L need a separate filter?
No β the P100 filter is built in, so there is no prefilter or retainer to add.
Does the 75852P100L fit North 5500 and 7700 respirators?
Yes. The North bayonet connection fits the 5500 and 7700 series half masks and the 5400 and 7600 series full-face respirators.
Is the 75852P100L cartridge reusable?
The cartridge is reusable until its gas or filter service life is reached; the respirator itself is reusable across many cartridge changes.
75852P100L Specifications
| Gas class | Mercury vapor and chlorine |
| Particulate filter | P100 β β₯99.97%, oil-proof (built in) |
| NIOSH markings | Orange (mercury/chlorine) + magenta (P100) |
| Connection | North bayonet |
| End-of-service-life indicator | Yes (mercury) |
Compatible North Respirators
The 75852P100L uses the North bayonet connection, so it mounts on the North half-mask respirators (5500 and 7700 series) and North full-face respirators (5400 and 7600 series). It does not fit 3M or MSA facepieces.
| Respirator | Type | Compatible? |
|---|---|---|
| North 5500 series | Half mask | Yes β bayonet |
| North 7700 series | Half mask | Yes β bayonet |
| North 7600 series | Full face | Yes β bayonet |
| North 5400 series | Full face | Yes β bayonet |
| 3M / MSA | Half / full | No (not bayonet-compatible) |
Helpful Buying Guides
- Honeywell North cartridge guide
- How to choose a respirator cartridge
- Organic vapor vs P100
- respirator cartridge color chart
- respirator filter types explained
- Honeywell North vs 3M respirators
75852P100L Frequently Asked Questions
What does the Honeywell North 75852P100L protect against?
The 75852P100L is a mercury vapor and chlorine / P100 combination cartridge. It captures mercury vapor and chlorine and filters at least 99.97% of airborne particulate, covering gas plus dust, mist and fume. It does not protect against organic vapor, ammonia or formaldehyde.
Does the Honeywell North 75852P100L filter dust?
Yes. The 75852P100L has a built-in P100 filter that captures at least 99.97% of airborne particles, including oil-based mists, so no separate prefilter is needed.
Which respirators does the Honeywell North 75852P100L fit?
The 75852P100L uses the North bayonet connection, so it fits North 5500 and 7700 series half-mask respirators and North 5400 and 7600 series full-face respirators. It does not fit 3M or MSA facepieces.
What does P100 mean on the 75852P100L?
P100 is the highest NIOSH particulate rating: oil-proof and at least 99.97% efficient. The 75852P100L carries a magenta P100 marking alongside its gas-class marking.
Is the Honeywell North 75852P100L NIOSH-approved?
Yes. The 75852P100L is NIOSH-approved under 42 CFR Part 84 for its listed gases and P100 particulate. It carries an end-of-service-life indicator (ESLI) for mercury. You can verify any cartridge against the NIOSH Certified Equipment List.
How often should I replace the Honeywell North 75852P100L?
Replace the gas portion on a documented change-out schedule or when you detect gas, and replace when breathing through the P100 filter becomes noticeably harder as particulate loads it.
Does the 75852P100L need a separate filter?
No. The P100 particulate filter is built in, so there is no prefilter or retainer to add. The 75852P100L cartridge is ready for both gas and particulate.
What is the difference between the 75852P100L and the N75002L?
Both cover the same gas, but the 75852P100L adds a P100 particulate filter. Choose the N75002L if there is no dust; the 75852P100L when gas and particulate are both present.
What do the colors on the 75852P100L mean?
The markings are orange (mercury/chlorine) + magenta (p100); confirm both your gas class and the P100 on the cartridge color chart before use.
Is this the genuine Honeywell North 75852P100L cartridge?
Yes. WC Safety sells authentic, NIOSH-approved Honeywell North 75852P100L cartridges through legitimate supply channels, so you avoid the counterfeits common on open marketplaces.
Can I buy the 75852P100L in bulk or by the case?
Yes. Use the Request a Quote option for case and pallet pricing on volume orders for crews, facilities and distributors.
How should I store the Honeywell North 75852P100L?
Store it sealed in its original packaging, away from gases and dust, so neither the gas nor filter service life is used up before you wear it.
Written by Steven Eaton, WC Safety Editorial β industrial respiratory protection desk. Reviewed by the WC Safety Editorial Team. Specifications sourced from Honeywell North published data and verified against the NIOSH Certified Equipment List. Compare the range in Honeywell North respirator filters & cartridges or start with the North cartridge guide.
WC Safety is an independent PPE retailer and Amazon Associate; no paid placement. Always verify cartridge compatibility and follow your written respiratory protection program. General information, not medical or regulatory advice.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.