Skip to content
Industrial Safety Equipment & PPE — ANSI/OSHA Compliant
Industrial Safety Equipment & PPE — ANSI/OSHA Compliant

GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, 1 Pair Review (2026)

Affiliate disclosure: As an Amazon Associate, WC Safety earns from qualifying purchases at no extra cost to you. We stock this product; commissions do not influence our review.

★★★★½ 4.5/5

Reviewed by Steven Eaton, WC Safety Editorial

GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, 1 Pair — Key Details
Brand GVS
Category Respirator Filter
Typical price $33.53
Model / SKU OVAG-P100

The GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, 1 Pair is a respirator filter from GVS, stocked at $33.53. This review restates what the product page documents, places it in its respiratory protection lane, and points to the ranked guides for the head-to-head field.

What the Product Page Documents

The GVS Elipse OVAG P100 is a third-generation multi-gas and dust replacement filter for GVS Elipse and Integra Low Profile OVAG P100 half-face respirators . Built on two GVS-patented technologies — "Encapsulation" of the HESPA filter media enabling a curved low-profile form factor, and graduated carbon that extends gas molecule adsorption path length through more adsorbent material — the result is a filter GVS states is 30% smaller in size and weight than conventional filters while delivering higher gas performance than standard carbon layer designs. Recommended for multi-gas and dust environments including all types of organic gases, inorganic gases, formaldehyde, chemical gases, and particulate dust. Note: ammonia is specifically excluded from the recommended application list — for ammonia environments, a cartridge with explicit ammonia NIOSH approval is required. Universal fit covers both Small/Medium and Medium/Large Elipse and Integra Low Profile facepieces. Sold as 1 pair (2 filters). Browse the full respirator filters and cartridges catalog at WC Safety.

Vendor: GVS | Model: OVAG P100 | ASIN: B0GGHVFRR2 | EAN: 5060233805051 | Pack: 1 Pair (2 filters)

GVS recommends this filter for chemical production and handling environments with multi-gas and dust risks. For compliance programs, confirm the specific substance and concentration against GVS's published filter specification and applicable NIOSH approval data. The APF is determined by the facepiece: APF 10 for a half-face respirator , APF 50 for a full-face respirator .

Where It Earns Its Slot

Where it earns its slot: The GVS Elipse OVAG P100 is a third-generation multi-gas and dust replacement filter for GVS Elipse and Integra Low Profile OVAG P100 half-face respirators . Built on two GVS-patented technologies — "Encapsulation" of th… The product page carries the full documented configuration; this review deliberately restates rather than embellishes it — claims beyond the listing don't appear here.

Honest Limits

Its honest limits: like every respiratory protection product, it protects within its stated ratings and use lane only — the family FAQ below draws those boundaries, and the guides linked underneath rank it against its true alternatives. Where the listing is silent on a spec, so are we; verify markings and instructions on arrival.

Pros and Cons

Pros

  • Documented respirator filter from GVS
  • Model OVAG-P100 — traceable part number
  • Listing-grounded specs — nothing invented here

Cons

  • Configuration options live on the linked listing
  • Where the listing is silent on a rating, verify the physical markings

Alternatives in the Same Lane

Respiratory Protection Guides

Browse by Category

Frequently Asked Questions

How much does the GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, cost?

$33.53 at the linked listing — prices track the live page, and configuration choices there can shift the number.

What does the GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, listing actually document?

The GVS Elipse OVAG P100 is a third-generation multi-gas and dust replacement filter for GVS Elipse and Integra Low Profile OVAG P100 half-face respirators . Built on two GVS-patented technologies — "Encapsulation" of the HESPA filter media enabling a curved low-profile form factor, and graduated ca…

What are the alternatives to the GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L,?

The sibling respirator filter options linked in this review, ranked head-to-head in the respiratory protection guides below — start with the buyer's guides for the field view.

What do N95, P100, and the letter/number classes mean?

The letter is oil resistance (N=not, R=resistant, P=oil-proof); the number is filtration efficiency (95/99/100 ≈ 95%/99%/99.97%). The class on the listing is the class — higher isn't always better if breathing resistance parks the mask on the chin.

When does OSHA require fit testing for this equipment?

Any employer-required tight-fitting respirator — N95s included — needs fit testing before use and annually per 1910.134, plus user seal checks every wearing. Loose-fitting PAPRs are the exception.

How long do cartridges and filters last?

Chemical cartridges follow a change schedule (or end-of-service indicators) — odor breakthrough is a failure, not a signal. Particulate filters last until breathing resistance rises or damage/loading shows. The employer's change schedule is a 1910.134 requirement.

Can I pair any cartridge with any facepiece?

No — attachment systems are proprietary (bayonet counts and geometries differ by brand and series). Reviews here restate the compatibility each listing claims; the manufacturer's matrix governs.

What does a respirator NOT protect against?

Air-purifying respirators don't supply oxygen — oxygen-deficient atmospheres and IDLH conditions require supplied air. And a cartridge only stops what its class covers; the SDS names the contaminant to match.

Why does facial hair matter?

Anything between skin and seal defeats tight-fitting respirators — it fails fit tests and the standard. The options are shaving policy or loose-fitting PAPRs; there is no third answer.

How should respirators be cleaned and stored?

Per 1910.134 Appendix B-2: cleaned and sanitized (alcohol-free wipes between uses, periodic washing), stored away from contamination, sunlight, and distortion. Filters stay sealed until service.

What's the difference between a half mask and full face for the same cartridge?

Assigned protection factor (10 vs 50 for full face) and eye protection — the same cartridge protects longer lungs-wise on a full face because leakage is lower. Exposure levels pick the facepiece.

Are exhalation valves allowed?

For most industrial use, yes — valves ease breathing without lowering protection for the wearer. Sterile fields and source-control settings restrict them; that's a policy question, not a NIOSH one.

What is an assigned protection factor (APF)?

The exposure multiplier a respirator class is credited with under 1910.134 — half masks 10, full face 50, PAPR hoods 25-1000 by type. Exposure over PEL×APF means stepping up the class.

PAPR vs negative-pressure — when to step up?

Comfort over long shifts, beards, high exposures, and heat all point to PAPRs — blown air instead of pulled. The cost gap narrows once cartridge consumption and compliance are priced in.

Do respirators expire?

Filters and cartridges carry shelf lives sealed; facepiece elastomers age with use and cleaning chemistry. Date-check stock, rotate it, and let the fit test catch what inspection misses.

The Bottom Line

Rated 4.5/5 on documented spec, configuration, and value. The GVS Elipse OVAG P100 Replacement Filters — Fits S/M and M/L, 1 Pair does the job its listing describes — the guides above tell you whether it's the right pick against the field.


About the Author

Steven Eaton is the founder of WC Safety and an industrial PPE specialist who sources and evaluates respiratory protection equipment for industrial and construction buyers.

How We Review

Respiratory reviews restate NIOSH approvals, filter classes, and compatibility exactly as listed — cartridge pairings follow the manufacturer's attachment rules (retainers where required, direct-attach where designed), and every tight-fitting respirator assumes the annual fit test our kits collection now sells. Ratings reflect documented spec, configuration, and value — the basis is stated, not invented testing.

Affiliate Disclosure

WC Safety is an Amazon Associate and earns commissions on qualifying purchases through links on this page. Affiliate relationships do not influence our ratings.

Editorial Standards

Claims are drawn from listing data and published standards. WC Safety does not invent specifications or test results. Report errors to safetynw2012@gmail.com.

Previous article AllaQuix Lite Hemostatic Gauze Pads, 4x4, Calcium Alginate Review (2026)

Leave a comment

* Required fields