Honeywell PA700 PAPR Decon Kit with PA101M
WC Safety Editorial Pick: The Honeywell PA700 is the gold standard for belt-worn PAPR systems in pharmaceutical, hazmat, and chemical environments β Honeywell's own responder-grade blower matched with the PA101M de...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
WC Safety Editorial Pick: The Honeywell PA700 is the gold standard for belt-worn PAPR systems in pharmaceutical, hazmat, and chemical environments β Honeywell's own responder-grade blower matched with the PA101M decon assembly for facilities where contamination control is critical.
The Honeywell PA700 Powered Air-Purifying Respirator Decon Kit delivers continuous clean airflow in IDLH-adjacent environments where disposable or cartridge respirators fall short. The PA700 blower unit produces a minimum 170 L/min of filtered air β well above NIOSH's 115 L/min threshold β providing positive pressure inside the headtop that prevents unfiltered air from entering even when the face seal is imperfect. If your workers are performing decontamination tasks, pharmaceutical compounding, or hazmat response, the PA700 with PA101M assembly is the kit to reach for.
The PA101M decontamination assembly included in this kit is designed for environments where the respirator itself may become contaminated and must be cleaned between uses. The assembly integrates with Honeywell's North series half-face and full-face respirators, and the breathing tube routes the filtered airflow from the belt-mounted blower to the face-piece with minimal resistance. The rechargeable lithium-ion battery pack is rated for 8+ hours of continuous operation at full flow, making full-shift use practical without battery swaps.
For procurement managers evaluating belt-worn PAPRs: the PA700 line uses the same filter and cartridge platform as Honeywell's other North series respiratory equipment, reducing your parts inventory. NIOSH approval covers both the blower assembly and the approved filter combinations. The kit includes the blower motor, battery, charger, and PA101M decon assembly β face-pieces and filters must be purchased separately based on your specific hazard profile.
Key Features
- Belt-mounted blower: 170 L/min minimum airflow β exceeds NIOSH 115 L/min minimum
- PA101M decontamination assembly included for contaminated-environment use
- Compatible with Honeywell North half-face and full-face respirators
- Rechargeable Li-ion battery: 8+ hours continuous runtime
- NIOSH-approved (AS designation for supplied air equivalency)
- Low-breathing-resistance: positive pressure prevents inward leakage
- Audible/visual low-battery and low-flow alarm
Technical Specifications
| Spec | Value |
|---|---|
| Flow Rate | 170 L/min minimum |
| Approval | NIOSH-approved (AS) |
| Battery Type | Rechargeable Lithium-Ion |
| Battery Life | 8+ hours |
| Wear Style | Belt-mounted |
| Compatible Face-Pieces | Honeywell North half-face and full-face series |
| Kit Contents | PA700 blower, battery, charger, PA101M decon assembly |
Pros & Cons
β Pros
- Exceeds NIOSH minimum flow rate β positive pressure headtop protection
- Decon assembly included β purpose-built for contamination-control environments
- Long battery life β full-shift operation without swap
- Honeywell North filter compatibility β unified parts inventory
β Cons
- Face-piece and filters sold separately β plan for additional cost
- Belt-mounted unit adds ~1 lb to worker's waistline
Shop Compatible PAPR Equipment
- All Powered Air Purifying Respirators
- PAPR Replacement Filters
- PAPR Cartridges
- Full-Face Respirators
- Half-Face Respirators
- 3M Versaflo TR-600-ECK Economy PAPR Starter Kit
- 3M Versaflo TR-300-HIK Heavy Industry PAPR Kit
- 3M Versaflo BT-30 Breathing Tube
- 3M Versaflo M-407 PAPR Helmet Assembly
- 3M Versaflo TR-6710N HE PAPR Filter
- Allegro EZ Air Max PAPR
- Allegro 9935-DLXE EZ Air Deluxe PAPR
- Sundstrom SR 500/520 PAPR Kit
- RPB Z-Link Respirator with PX5 PAPR
- 3M Powerflow 6800PF PAPR Respirator
Frequently Asked Questions
Is the Honeywell PA700 NIOSH approved?
Yes. The PA700 PAPR system is NIOSH-approved under the AS (Atmosphere-Supplying) classification, confirming it meets federal performance standards for powered air-purifying respirators.
What face-pieces are compatible with the PA700?
The PA700 blower is compatible with Honeywell North half-face and full-face respirator series. Check Honeywell's current compatibility chart for specific model numbers, as adapters may be required for certain face-pieces.
Does the PA700 kit include filters?
No. Filters and cartridges must be purchased separately based on your specific hazard. Honeywell offers HEPA, organic vapor, acid gas, and combination cartridges for the North respirator platform.
How long does the PA700 battery last?
The rechargeable lithium-ion battery delivers 8+ hours of continuous operation at full flow, covering a standard 8-hour shift without a battery swap.
What is the PA101M decon assembly used for?
The PA101M decontamination assembly is designed for environments where the respirator may become contaminated between uses, such as hazmat response or pharmaceutical clean-room entry. It provides a structural interface for the breathing tube and face-piece that can be decontaminated and reused.
Can the PA700 be used for asbestos abatement?
The PA700 with an appropriate HEPA or P100 filter can provide assigned protection factor (APF) 1000 when used as a tight-fitting PAPR, or APF 25 in loose-fitting headtop mode. Consult your industrial hygienist for asbestos-specific regulatory requirements.
What is the flow rate of the PA700 blower?
The PA700 produces a minimum of 170 L/min, which exceeds the NIOSH-required 115 L/min minimum for belt-worn PAPRs.
Is the PA700 suitable for confined space entry?
The PA700 is a PAPR (air-purifying), not a supplied-air respirator. It should not be used in atmospheres with less than 19.5% oxygen or IDLH concentrations. For confined spaces with oxygen deficiency, a supplied-air or SCBA system is required.
How do I clean the PA700 blower unit?
Wipe the blower housing with a damp cloth and approved disinfectant. Do not submerge the blower unit. Clean the breathing tube and face-piece per Honeywell's cleaning instructions after each use.
What is included in the PA700 Decon Kit?
The kit includes the PA700 blower motor, rechargeable lithium-ion battery pack, battery charger, and the PA101M decontamination assembly. Face-pieces and filter cartridges are purchased separately.
Does the PA700 have a low-flow alarm?
Yes. The PA700 includes an audible and visual alarm that alerts the wearer when airflow drops below the safe minimum threshold, warning of filter loading or battery depletion.
Where can I buy replacement parts for the PA700?
Replacement batteries, breathing tubes, and filter cartridges for the Honeywell PA700 are available through WC Safety. See our PAPR Cartridges and PAPR Filters collections.
Written by Steven Eaton, WC Safety β PPE Specialist with 10+ years sourcing and evaluating industrial respiratory protection. All specifications are manufacturer-verified or NIOSH-documented.
Reviewed by: WC Safety Editorial Team | Buy Honeywell PA700 PAPR Decon Kit with PA101M on Amazon β
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.