Honeywell North 7584P100L Ammonia Methylamine P100 Respirator Cartridge
EDITORIAL REVIEW: 4.5/5 Independently reviewed by WC Safety "Specialized ammonia + P100 β excellent when NHβ is the documented primary hazard" Read the full review β Β· 2026 North cartr...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Honeywell North 7584P100L β Ammonia/Methylamine + P100 Combination Cartridge, NIOSH 42 CFR 84, Pair
The Honeywell North 7584P100L is a NIOSH 42 CFR 84 ammonia + methylamine + P100 combination cartridge providing protection against ammonia, methylamine, and 99.97% P100 particulate filtration β sold as a pair for the North bayonet system. The 7584P100L is the correct cartridge when ammonia is the documented primary gaseous hazard and organic vapors or acid gases are not co-present. In environments where OV, AG, and NHβ are all present, the 75SCP100L (OV+AG+NHβ+P100) provides full multi-contaminant coverage. If only OV and ammonia are present without acid gas, the N75004L gas-only covers the same gases without P100 (lower breathing resistance when particles are absent). Compatible with all North 7700, 5500, 5400, and 7600 series facepieces.
- Model: Honeywell North 7584P100L
- Type: Ammonia/Methylamine + P100 Combination Cartridge β sold as a pair
- NIOSH Approval: 42 CFR 84 Ammonia/Methylamine + P100
- Gas Coverage: Ammonia (NHβ) and methylamine β does NOT cover OV or acid gases
- Particle Coverage: P100 β 99.97% all particle types
- APF (Half-Mask): 10 on North 770030 and 550030 series
- APF (Full-Face): 50 on North 54001 and 760008 series
- Connector: North bayonet twist-lock
- Multi-contaminant alternative: 75SCP100L when OV/AG are also present
Key Features
- Ammonia + methylamine NIOSH approval: Specifically formulated sorbent for basic gas classes including NHβ and methylamine β not interchangeable with acid gas or OV sorbents
- Integrated P100: Covers airborne particles simultaneously β correct for ammonia environments that also generate dust or aerosol (e.g., agricultural operations with dust co-exposure, biological material)
- Sold as a pair: Two cartridges per package for both positions on a North facepiece
- Narrow hazard profile: The 7584P100L is a specialized cartridge for documented NHβ/MA environments. For broader chemical coverage including OV and acid gas, the 75SCP100L is the more defensible choice when the hazard profile is not fully characterized
Applications β When to Use the 7584P100L
The 7584P100L is the correct cartridge when ammonia or methylamine is the confirmed primary gas hazard and particles are also present:
- Wastewater treatment: NHβ off-gassing from sewage processing with aerosol co-exposure β P100 covers biological aerosol, NHβ sorbent covers gas phase
- Agriculture and livestock: Poultry houses, hog confinements, and manure management where ammonia concentrations exceed OEL thresholds and organic dust is co-present
- Industrial refrigeration: Ammonia refrigerant leak response and maintenance where refrigerant particulate mist or oil aerosol may accompany vapor release
- Fertilizer manufacturing: Anhydrous ammonia handling and urea processing operations with dust co-exposure
- Fish processing: Trimethylamine and methylamine from fish protein decomposition β both covered by this cartridge's NIOSH approval
If organic vapors or acid gases are also documented: Use the 75SCP100L (OV+AG+NHβ+P100). If no particles are present, consider the gas-only N75004L for lower breathing resistance.
Compatible Respirators
All Honeywell North 7-series and N-series cartridges use the North bayonet twist-lock connector, compatible with the following facepieces.
| Respirator | Type | APF | Notes |
|---|---|---|---|
| North 770030S | Half-Mask | 10 | Small |
| North 770030M | Half-Mask | 10 | Medium β start here if unsure of size |
| North 770030L | Half-Mask | 10 | Large |
| North 550030S | Half-Mask | 10 | Small β silicone facepiece |
| North 550030M | Half-Mask | 10 | Medium β silicone facepiece |
| North 550030L | Half-Mask | 10 | Large β silicone facepiece |
| North 54001S | Full-Face | 50 | Small β integrated eye protection |
| North 54001 | Full-Face | 50 | M/L β integrated eye protection |
| North 760008AS | Full-Face | 50 | Small β wide-view lens |
| North 760008A | Full-Face | 50 | M/L β wide-view lens |
North Cartridge & Filter Line β Full Comparison
All cartridges use the same North bayonet connector. Select based on documented hazard class.
| Model | Protection Class | Best For |
|---|---|---|
| P100 PARTICULATE FILTERS | ||
| 7580P100 | P100 β 99.97% | Silica, lead, asbestos, welding fume β particulate only (2-pack) |
| 75FFP100 | P100 β 99.97% | Same as 7580P100 β single unit |
| COMBINATION CARTRIDGES (GAS + P100) | ||
| 7581P100L | OV + P100 | Spray painting, solvents β OV and particles confirmed, no acid gas |
| 7582P100L | AG + P100 | HCl, HF, SOβ, Clβ, HβS β acid-only, OV formally excluded |
| 7583P100L | OV + AG + P100 | Mixed chemical environments β broader and cheaper than 7582P100L |
| 7584P100L | NHβ/MA + P100 | Wastewater, agriculture, refrigeration β ammonia primary hazard |
| 75SCP100L | OV + AG + NHβ + P100 | Multi-hazard / uncertain profile β broadest North-line coverage |
| 75852P100L | Mercury + Cl + P100 | Chlor-alkali, fluorescent lamp recycling β only North Hg cartridge |
| GAS-ONLY CARTRIDGES (NO P100) | ||
| N75001L | OV only | Pure vapor β no particles present |
| N75002L | OV + AG | Chemical work β no particles |
| N75003L | OV + AG + NHβ | Triple gas β wastewater, agriculture |
| N75004L | OV + NHβ | OV + ammonia β acid gas excluded |
| 75SCL | OV + AG + NHβ | Defender series β pure gas, lowest breathing resistance |
| SNAP-ON PREFILTERS | ||
| 7506N95 | N95 snap-on | Particle upgrade for gas cartridges β dry environments |
| 7506R95 | R95 snap-on | Oil mist / metalworking upgrade for gas cartridges |
| 7506N99 | N99 snap-on | Fine silica / pharma upgrade for gas cartridges |
| 7504R95 | R95 holder system | Oil mist β North cartridge holder format |
Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β
OSHA Compliance
- NIOSH approval required: All cartridges in OSHA-mandated programs must be NIOSH approved under 42 CFR Part 84
- Hazard assessment required: OSHA 1910.134(d)(1) β cartridge type must match the documented workplace hazard class
- Fit testing required: OSHA 1910.134(f)(2) β annual fit testing for any tight-fitting facepiece, regardless of cartridge type
- Cartridge change schedule: OSHA 1910.134(d)(3)(iii) β end-of-service-life for gas/vapor cartridges must be established before use
- Medical evaluation: OSHA 1910.134(e) β required before fit testing and before operational respirator use
Frequently Asked Questions
What does the 7584P100L protect against?
Ammonia (NHβ), methylamine, and P100 99.97% particle filtration. It does not protect against organic vapors, acid gases, mercury, or CO. For environments with OV + AG + NHβ, use the 75SCP100L.
Which respirators does the 7584P100L fit?
All North bayonet facepieces: North 770030 series (S/M/L), North 550030 series (S/M/L), North 54001 and 54001S, North 760008A and 760008AS.
Is the 7584P100L appropriate for poultry houses?
Yes β poultry houses with documented NHβ above the OSHA PEL (50 ppm) combined with organic dust co-exposure are the core application for this cartridge. Confirm that the NHβ concentration is within APF 10 (β€500 ppm) for half-mask use, or APF 50 (β€2,500 ppm) for full-face. Ammonia IDLH is 300 ppm β above this level, supplied-air is required.
What is the ammonia OSHA PEL and when do I need a respirator?
OSHA PEL for ammonia is 50 ppm (TWA). Respirators are required when engineering controls do not reduce exposure below PEL. A half-mask with APF 10 is appropriate for exposures up to 500 ppm (10Γ PEL). Above 300 ppm (IDLH), supplied-air is required β do not use air-purifying respirators at or above IDLH.
Can the 7584P100L be used for refrigerant ammonia leaks?
For routine maintenance and low-level leak response where concentrations are below IDLH (300 ppm): yes, with confirmed fit-tested facepiece. For emergency response or potential high-concentration releases, SCBA (self-contained breathing apparatus) is required per OSHA 1910.120 and NFPA 1.
How do I know when the 7584P100L is saturated?
Ammonia has a low odor threshold (~1β5 ppm) relative to its PEL (50 ppm) β if you detect ammonia odor through the respirator, the cartridge may be near end-of-service-life. However, OSHA requires a written change-out schedule under 1910.134(d)(3)(iii) β do not rely solely on odor. Establish a schedule based on monitoring data and sorbent capacity.
Is there a gas-only version of this cartridge without P100?
Yes β the N75004L provides OV + NHβ without a P100 layer. It has lower breathing resistance and is correct when no particles are present. If both NHβ and organic vapors are present without particles, the N75004L is the appropriate choice.
Does the 7584P100L cover hydrogen sulfide?
No β HβS is an acid gas (low pH), not a basic gas. It is covered by the 7582P100L (AG+P100) or 7583P100L (OV+AG+P100). For environments with both HβS and NHβ, the 75SCP100L is required.
Is fit testing required?
Yes β OSHA 1910.134(f)(2). Annual fit testing for the facepiece before operational use. Cartridge type does not change the fit test requirement.
Where can I find all North cartridges?
Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.