Skip to content
Welcome To WC Safety. Your Home to Everything Safety
Welcome To WC Safety. Your Home to Everything Safety
Home β€Ί Honeywell North Respirator Cartridges β€Ί Honeywell North 7584P100L Ammonia Methylamine P...

Honeywell North 7584P100L Ammonia Methylamine P100 Respirator Cartridge

Honeywell North SKU: 7584P100L Respirator Cartridges
β˜… β˜… β˜… β˜… β˜… 4.8 (3 reviews on WC Safety)
$41.95
Final price set by Amazon Β· may vary

EDITORIAL REVIEW: 4.5/5 Independently reviewed by WC Safety "Specialized ammonia + P100 β€” excellent when NH₃ is the documented primary hazard" Read the full review β†’ Β· 2026 North cartr...

Check Price on Amazon

πŸ”’ Amazon Associate Β· You pay the same price Β· We earn a small commission

Zero Sponsored ListingsNo paid placements. Every recommendation is based on compliance, build quality, and field performance.
Curated SelectionExpert-chosen safety gear
Independently ReviewedUnbiased assessments β€” no manufacturer input
Built for Industrial BuyersSourced and reviewed for safety managers, procurement teams, and field supervisors.
Ammonia Methylamine P100

Honeywell North 7584P100L β€” Ammonia/Methylamine + P100 Combination Cartridge, NIOSH 42 CFR 84, Pair

The Honeywell North 7584P100L is a NIOSH 42 CFR 84 ammonia + methylamine + P100 combination cartridge providing protection against ammonia, methylamine, and 99.97% P100 particulate filtration β€” sold as a pair for the North bayonet system. The 7584P100L is the correct cartridge when ammonia is the documented primary gaseous hazard and organic vapors or acid gases are not co-present. In environments where OV, AG, and NH₃ are all present, the 75SCP100L (OV+AG+NH₃+P100) provides full multi-contaminant coverage. If only OV and ammonia are present without acid gas, the N75004L gas-only covers the same gases without P100 (lower breathing resistance when particles are absent). Compatible with all North 7700, 5500, 5400, and 7600 series facepieces.

Quick Facts β€” 7584P100L
  • Model: Honeywell North 7584P100L
  • Type: Ammonia/Methylamine + P100 Combination Cartridge β€” sold as a pair
  • NIOSH Approval: 42 CFR 84 Ammonia/Methylamine + P100
  • Gas Coverage: Ammonia (NH₃) and methylamine β€” does NOT cover OV or acid gases
  • Particle Coverage: P100 β€” 99.97% all particle types
  • APF (Half-Mask): 10 on North 770030 and 550030 series
  • APF (Full-Face): 50 on North 54001 and 760008 series
  • Connector: North bayonet twist-lock
  • Multi-contaminant alternative: 75SCP100L when OV/AG are also present

Key Features

  • Ammonia + methylamine NIOSH approval: Specifically formulated sorbent for basic gas classes including NH₃ and methylamine β€” not interchangeable with acid gas or OV sorbents
  • Integrated P100: Covers airborne particles simultaneously β€” correct for ammonia environments that also generate dust or aerosol (e.g., agricultural operations with dust co-exposure, biological material)
  • Sold as a pair: Two cartridges per package for both positions on a North facepiece
  • Narrow hazard profile: The 7584P100L is a specialized cartridge for documented NH₃/MA environments. For broader chemical coverage including OV and acid gas, the 75SCP100L is the more defensible choice when the hazard profile is not fully characterized

Applications β€” When to Use the 7584P100L

The 7584P100L is the correct cartridge when ammonia or methylamine is the confirmed primary gas hazard and particles are also present:

  • Wastewater treatment: NH₃ off-gassing from sewage processing with aerosol co-exposure β€” P100 covers biological aerosol, NH₃ sorbent covers gas phase
  • Agriculture and livestock: Poultry houses, hog confinements, and manure management where ammonia concentrations exceed OEL thresholds and organic dust is co-present
  • Industrial refrigeration: Ammonia refrigerant leak response and maintenance where refrigerant particulate mist or oil aerosol may accompany vapor release
  • Fertilizer manufacturing: Anhydrous ammonia handling and urea processing operations with dust co-exposure
  • Fish processing: Trimethylamine and methylamine from fish protein decomposition β€” both covered by this cartridge's NIOSH approval

If organic vapors or acid gases are also documented: Use the 75SCP100L (OV+AG+NH₃+P100). If no particles are present, consider the gas-only N75004L for lower breathing resistance.

Compatible Respirators

All Honeywell North 7-series and N-series cartridges use the North bayonet twist-lock connector, compatible with the following facepieces.

Respirator Type APF Notes
North 770030S Half-Mask 10 Small
North 770030M Half-Mask 10 Medium β€” start here if unsure of size
North 770030L Half-Mask 10 Large
North 550030S Half-Mask 10 Small β€” silicone facepiece
North 550030M Half-Mask 10 Medium β€” silicone facepiece
North 550030L Half-Mask 10 Large β€” silicone facepiece
North 54001S Full-Face 50 Small β€” integrated eye protection
North 54001 Full-Face 50 M/L β€” integrated eye protection
North 760008AS Full-Face 50 Small β€” wide-view lens
North 760008A Full-Face 50 M/L β€” wide-view lens

North Cartridge & Filter Line β€” Full Comparison

All cartridges use the same North bayonet connector. Select based on documented hazard class.

Model Protection Class Best For
P100 PARTICULATE FILTERS
7580P100 P100 β€” 99.97% Silica, lead, asbestos, welding fume β€” particulate only (2-pack)
75FFP100 P100 β€” 99.97% Same as 7580P100 β€” single unit
COMBINATION CARTRIDGES (GAS + P100)
7581P100L OV + P100 Spray painting, solvents β€” OV and particles confirmed, no acid gas
7582P100L AG + P100 HCl, HF, SOβ‚‚, Clβ‚‚, Hβ‚‚S β€” acid-only, OV formally excluded
7583P100L OV + AG + P100 Mixed chemical environments β€” broader and cheaper than 7582P100L
7584P100L NH₃/MA + P100 Wastewater, agriculture, refrigeration β€” ammonia primary hazard
75SCP100L OV + AG + NH₃ + P100 Multi-hazard / uncertain profile β€” broadest North-line coverage
75852P100L Mercury + Cl + P100 Chlor-alkali, fluorescent lamp recycling β€” only North Hg cartridge
GAS-ONLY CARTRIDGES (NO P100)
N75001L OV only Pure vapor β€” no particles present
N75002L OV + AG Chemical work β€” no particles
N75003L OV + AG + NH₃ Triple gas β€” wastewater, agriculture
N75004L OV + NH₃ OV + ammonia β€” acid gas excluded
75SCL OV + AG + NH₃ Defender series β€” pure gas, lowest breathing resistance
SNAP-ON PREFILTERS
7506N95 N95 snap-on Particle upgrade for gas cartridges β€” dry environments
7506R95 R95 snap-on Oil mist / metalworking upgrade for gas cartridges
7506N99 N99 snap-on Fine silica / pharma upgrade for gas cartridges
7504R95 R95 holder system Oil mist β€” North cartridge holder format

Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β†’

OSHA Compliance

  • NIOSH approval required: All cartridges in OSHA-mandated programs must be NIOSH approved under 42 CFR Part 84
  • Hazard assessment required: OSHA 1910.134(d)(1) β€” cartridge type must match the documented workplace hazard class
  • Fit testing required: OSHA 1910.134(f)(2) β€” annual fit testing for any tight-fitting facepiece, regardless of cartridge type
  • Cartridge change schedule: OSHA 1910.134(d)(3)(iii) β€” end-of-service-life for gas/vapor cartridges must be established before use
  • Medical evaluation: OSHA 1910.134(e) β€” required before fit testing and before operational respirator use

Frequently Asked Questions

What does the 7584P100L protect against?

Ammonia (NH₃), methylamine, and P100 99.97% particle filtration. It does not protect against organic vapors, acid gases, mercury, or CO. For environments with OV + AG + NH₃, use the 75SCP100L.

Which respirators does the 7584P100L fit?

All North bayonet facepieces: North 770030 series (S/M/L), North 550030 series (S/M/L), North 54001 and 54001S, North 760008A and 760008AS.

Is the 7584P100L appropriate for poultry houses?

Yes β€” poultry houses with documented NH₃ above the OSHA PEL (50 ppm) combined with organic dust co-exposure are the core application for this cartridge. Confirm that the NH₃ concentration is within APF 10 (≀500 ppm) for half-mask use, or APF 50 (≀2,500 ppm) for full-face. Ammonia IDLH is 300 ppm β€” above this level, supplied-air is required.

What is the ammonia OSHA PEL and when do I need a respirator?

OSHA PEL for ammonia is 50 ppm (TWA). Respirators are required when engineering controls do not reduce exposure below PEL. A half-mask with APF 10 is appropriate for exposures up to 500 ppm (10Γ— PEL). Above 300 ppm (IDLH), supplied-air is required β€” do not use air-purifying respirators at or above IDLH.

Can the 7584P100L be used for refrigerant ammonia leaks?

For routine maintenance and low-level leak response where concentrations are below IDLH (300 ppm): yes, with confirmed fit-tested facepiece. For emergency response or potential high-concentration releases, SCBA (self-contained breathing apparatus) is required per OSHA 1910.120 and NFPA 1.

How do I know when the 7584P100L is saturated?

Ammonia has a low odor threshold (~1–5 ppm) relative to its PEL (50 ppm) β€” if you detect ammonia odor through the respirator, the cartridge may be near end-of-service-life. However, OSHA requires a written change-out schedule under 1910.134(d)(3)(iii) β€” do not rely solely on odor. Establish a schedule based on monitoring data and sorbent capacity.

Is there a gas-only version of this cartridge without P100?

Yes β€” the N75004L provides OV + NH₃ without a P100 layer. It has lower breathing resistance and is correct when no particles are present. If both NH₃ and organic vapors are present without particles, the N75004L is the appropriate choice.

Does the 7584P100L cover hydrogen sulfide?

No β€” Hβ‚‚S is an acid gas (low pH), not a basic gas. It is covered by the 7582P100L (AG+P100) or 7583P100L (OV+AG+P100). For environments with both Hβ‚‚S and NH₃, the 75SCP100L is required.

Is fit testing required?

Yes β€” OSHA 1910.134(f)(2). Annual fit testing for the facepiece before operational use. Cartridge type does not change the fit test requirement.

Where can I find all North cartridges?

Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β†’

Brand / Vendor
Honeywell North
Model / SKU
7584P100L
Product Type
Respirator Cartridges
Condition
New
MPN
7584P100L
Price
$41.95 (Amazon)
Rating
4.8 / 5 β€” 3 reviews
Availability
βœ“ In Stock on Amazon
🏷️
No Paid Placements
Every product earns its place based on safety credentials and field performance, not advertising spend.
🏭
Industrial Grade Only
Products sourced for professional use in manufacturing, construction, and industrial environments.
πŸ”¬
Compliance Verified
Every product listed on WC Safety is reviewed for standards compliance and safety credentials before publication.
🏭
Sourced for Professionals
Gear selected for safety managers, procurement teams, and field supervisors β€” not casual consumers.
Share Your Experience

Write a Review

Select a rating
βœ“

Thank you for your review!

Your submission has been received and will be published after verification.

Honeywell North 7584P100L Ammonia Methylamine P100 Respirator Cartridge