3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter

3M SKU: D3076HF Respirator Filter GTIN: 0051131278127
$20.10
Final price set by Amazon Β· may vary

Editor's take: The 3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter pairs P95 particulate protection with a dedicated, NIOSH-tested hydrogen fluoride gas rating β€” not just an aerosol sorbent. If your progr...

Check Price on Amazon

πŸ”’ Amazon Associate Β· You pay the same price Β· We earn a small commission

Zero Sponsored ListingsNo paid placements. Rankings are never sold or influenced by manufacturers.
Independent Product ResearchBuilt from manufacturer specifications, published standards information, and cited sources
Standards MatterRatings and markings vary by model and variant β€” verify the manufacturer’s documented rating for your hazard
Built for Industrial BuyersResearch written for safety managers, procurement teams, and field supervisors.
3M Combination Cartridge dual-flow FF-800 HF HF-800 Hydrogen Fluoride NIOSH Approved
Editor's take:

The 3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter pairs P95 particulate protection with a dedicated, NIOSH-tested hydrogen fluoride gas rating β€” not just an aerosol sorbent. If your program requires P100 efficiency or a hard-case filter for the same HF work, step up to the 3M D9093C. Browse the full 3M respirator filters and cartridges collection, or compare filter classes in the P100 vs N95 guide.

Check Price on Amazon β€Ί
As an Amazon Associate, WC Safety earns from qualifying purchases.

3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter overview

The 3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter is a NIOSH-approved P95 particulate filter that carries its own dedicated hydrogen fluoride (HF) rating β€” 3M's official name for it is the "P95/Hydrogen Fluoride w/ Nuisance Acid Gas Relief" cartridge. It's tested and rated for HF gas up to 10 times the OSHA permissible exposure limit (PEL) on a half-mask Secure Click facepiece, the standard protection-factor ceiling that applies to any air-purifying cartridge on a half mask. It uses 3M's Secure Click push-to-connect mount and seats with an audible click on 3M HF-800 half-facepiece and FF-800 full-facepiece respirators β€” it will not fit any 3M bayonet respirator. See our respirator filter types explained guide and the 3M filter and cartridge guide to confirm your exposure before ordering.

Beyond hydrogen fluoride, the D3076HF also provides nuisance-level relief for other acid gases such as chlorine, hydrogen chloride, and sulfur dioxide β€” relief from odor and irritation at concentrations below their own PEL, not a rated acid-gas cartridge for those gases; browse the nuisance-relief respirators collection for the broader category. For P100 particulate efficiency with the same HF gas rating in a hard polycarbonate case, step up to the 3M D9093C. For general particulate work with no HF exposure, the D3071 or D3078 cost less.

Safety note β€” not rated for IDLH atmospheres or hazards beyond hydrogen fluoride.

The D3076HF's hydrogen fluoride rating is capped at 10x the OSHA PEL on a half-mask facepiece β€” it is not rated for concentrations above that limit, and no air-purifying filter is suitable for IDLH atmospheres, sandblasting, or asbestos. Its acid-gas relief beyond hydrogen fluoride is nuisance-level only. For organic vapor, ammonia, formaldehyde, or hazardous concentrations of any gas other than hydrogen fluoride, use a Secure Click combination cartridge matched to that specific hazard, or supplied-air equipment where concentrations are unknown or unconfirmed. A cartridge or filter carries no assigned protection factor of its own β€” the APF comes from the facepiece it is fitted to: 10 for a half mask, 50 for a full facepiece (OSHA 1910.134 Table 1), which is the number that decides the highest exposure the respirator may legally be worn in. That facepiece must be fit tested before first use and at least annually, and a fit test is specific to one make, model, and size β€” passing on one mask does not carry over to another. Perform a user seal check every time the respirator is donned, and note that facial hair crossing the sealing surface disqualifies a tight-fitting respirator no matter how well it fit at the last test.

Where it fits

Identify your hazard before choosing any filter β€” ideally through an industrial-hygiene assessment. Reach for the D3076HF in semiconductor wet-bench HF processes, fluoropolymer processing, and HF acid cleaning where hydrogen fluoride exposure is confirmed at or below 10x the PEL and P95 efficiency meets your standard. For P100 efficiency or a hard-case filter in the same HF work, the 3M D9093C is the upgrade, and the 3M D3096 covers P100 particulate with nuisance acid gas relief when HF specifically isn't present. If your process generates other gases above nuisance levels, step to a matched combination cartridge from the how to choose a respirator cartridge guide.

Pros & cons

Pros
  • Dedicated, NIOSH-tested hydrogen fluoride gas rating (10x PEL)
  • P95 particulate capture, oil-proof rated
  • Nuisance-level relief for other acid gases
  • Secure Click push-to-connect β€” fast, audible-click seating
Keep in mind
  • HF rating caps at 10x PEL β€” not for IDLH concentrations
  • P95, not P100 β€” the D9093C is the higher-efficiency option
  • Other acid gases get nuisance relief only, not a full rating
  • Secure Click-only β€” won't fit 3M bayonet respirators

Specifications

Brand / Model 3M Β· D3076HF
Particulate class P95 (oil-proof), NIOSH TC-21C
Gas rating Hydrogen fluoride, up to 10x PEL (half mask); nuisance-level relief for other acid gases
Connection 3M Secure Click push-to-connect (HF-800 / FF-800 only)
Housing Soft (hard-case upgrade: D9093C)
Package quantity 1 pair (2 filters)
Replacement Per your change-out schedule, or on damage/breakthrough

Related guides

Related resources

Frequently asked questions

What is the 3M Secure Click D3076HF used for?

P95 particulate protection plus a dedicated hydrogen fluoride gas rating (up to 10x PEL) and nuisance acid gas relief, on 3M Secure Click HF-800 and FF-800 respirators β€” common in semiconductor wet-bench HF processes, fluoropolymer processing, and HF acid work.

Does the D3076HF protect against hydrogen fluoride gas, or only mist?

It's NIOSH-tested and rated for hydrogen fluoride gas specifically, up to 10 times the OSHA PEL on a half-mask Secure Click facepiece β€” the standard half-mask protection-factor ceiling. It is not rated for HF concentrations above that limit or for atmospheres immediately dangerous to life or health.

What does "nuisance acid gas relief" mean on the D3076HF?

It's supplemental relief from odor and irritation caused by other acid gases β€” chlorine, hydrogen chloride, sulfur dioxide, and similar β€” at concentrations below their own OSHA PEL. It is not a rated acid-gas cartridge for those other gases and should not be relied on above nuisance levels.

What respirators does the D3076HF fit?

Only the 3M Secure Click platform: HF-800 series half-facepieces and FF-800 series full facepieces. It does not fit any 3M bayonet respirator, including the 6000, 6500QL, 7500, 7800S, or FF-400 series.

What's the difference between the D3076HF and the D9093C?

The D3076HF is P95 with a soft filter housing. The D9093C is P100 (higher particulate efficiency) with a hard polycarbonate case. Both carry the same dedicated hydrogen fluoride gas rating and Secure Click mount; choose the D9093C when your program requires P100 efficiency or a hard-case filter.

Is the D3076HF P95 or P100?

P95 β€” it captures at least 95% of airborne particles and is oil-proof rated. For P100 (β‰₯99.97%) with the same HF gas rating on Secure Click, the D9093C is the correct filter.

Can I use the D3076HF in an atmosphere immediately dangerous to life or health?

No. The D3076HF is an air-purifying filter, not supplied air. It is not rated for atmospheres immediately dangerous to life or health, sandblasting, or asbestos, and it does not protect against hazardous concentrations of any gas or vapor other than hydrogen fluoride.

Does the D3076HF protect against organic vapor or ammonia?

No. Its only tested gas rating is hydrogen fluoride, plus nuisance-level relief for other acid gases. Organic vapor, ammonia, formaldehyde, and other gas classes require a Secure Click combination cartridge matched to that hazard.

What is the pack quantity for the D3076HF?

Sold as a 1-pair pack β€” two filters, one for each side of a Secure Click facepiece.

How does the D3076HF compare to the D3071?

Both are Secure Click P95 filters. The D3071 is general particulate only, with no hydrogen fluoride rating, and typically costs less. Buy the D3076HF only when your hazard assessment confirms hydrogen fluoride exposure.

Can I use the D3076HF on the FF-800 full-face respirator?

Yes. The FF-800 is a Secure Click full facepiece, and the D3076HF's push-to-connect mount seats on it the same way it does on the HF-800 half-facepiece.

When should I replace the D3076HF?

Replace it when damaged, soiled, or difficult to breathe through, or per your employer's written respiratory protection program change-out schedule β€” service life against hydrogen fluoride depends on concentration and exposure time, so don't rely on breathing resistance alone.


Reviewed by Steven Eaton, WC Safety. Specifications reflect 3M's published data for the D3076HF Secure Click filter; hydrogen fluoride exposure limits and respirator selection should follow OSHA 1910.134 and a workplace hazard assessment. Atmospheres above the filter's rated limit, or that are immediately dangerous to life or health, require supplied-air equipment.

Read our detailed 3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter review β€” strengths, limitations, and the alternatives that matter.

Brand / Vendor
3M
Model / SKU
D3076HF
Product Type
Respirator Filter
Price
$20.10 (Amazon)
Availability
Check current availability on Amazon
🏷️
No Paid Placements
Every product earns its place on documented safety credentials and specifications β€” never advertising spend.
🏭
Industrial Grade Only
Coverage focuses on equipment built for professional use in manufacturing, construction, and industrial environments.
πŸ”¬
Independent Product Research
Product information is compiled from manufacturer specifications, published standards information, compatibility data, and other cited sources.
ℹ️
Affiliate Disclosure
WC Safety may earn commissions from qualifying purchases made through affiliate links. Affiliate relationships never change the specifications presented.
Verified Buyer Reviews

Customer Reviews

Share Your Experience

Write a Review

Select a rating
βœ“

Thank you for your review!

Your submission has been received and will be published after verification.

3M Secure Click D3076HF P95 + Hydrogen Fluoride Filter

Frequently Asked Questions

What is the 3M Secure Click D3076HF used for?
P95 particulate protection plus a dedicated hydrogen fluoride gas rating (up to 10x PEL) and nuisance acid gas relief, on 3M Secure Click HF-800 and FF-800 respirators β€” common in semiconductor wet-bench HF processes, fluoropolymer processing, and HF acid work.
Does the D3076HF protect against hydrogen fluoride gas, or only mist?
It's NIOSH-tested and rated for hydrogen fluoride gas specifically, up to 10 times the OSHA PEL on a half-mask Secure Click facepiece (the standard half-mask protection-factor ceiling). It is not rated for HF concentrations above that limit or for atmospheres immediately dangerous to life or health.
What does nuisance acid gas relief mean on the D3076HF?
It's supplemental relief from odor and irritation caused by other acid gases (chlorine, hydrogen chloride, sulfur dioxide, etc.) at concentrations below their own OSHA PEL. It is not a rated acid-gas cartridge for those other gases and should not be relied on above nuisance levels.
What respirators does the D3076HF fit?
Only the 3M Secure Click platform: HF-800 series half-facepieces and FF-800 series full facepieces. It does not fit any 3M bayonet respirator, including the 6000, 6500QL, 7500, 7800S, or FF-400 series.
What's the difference between the D3076HF and the D9093C?
The D3076HF is P95 with a soft filter housing. The D9093C is P100 (higher particulate efficiency) with a hard polycarbonate case. Both carry the same dedicated hydrogen fluoride gas rating and Secure Click mount; choose the D9093C when your program requires P100 efficiency or a hard-case filter.
Is the D3076HF P95 or P100?
P95 β€” it captures at least 95% of airborne particles and is oil-proof rated. For P100 (β‰₯99.97%) with the same HF gas rating on Secure Click, the D9093C is the correct filter.
Can I use the D3076HF in an atmosphere immediately dangerous to life or health?
No. The D3076HF is an air-purifying filter, not supplied air. It is not rated for atmospheres immediately dangerous to life or health, sandblasting, or asbestos, and it does not protect against hazardous concentrations of any gas or vapor other than hydrogen fluoride.
Does the D3076HF protect against organic vapor or ammonia?
No. Its only tested gas rating is hydrogen fluoride, plus nuisance-level relief for other acid gases. Organic vapor, ammonia, formaldehyde, and other gas classes require a Secure Click combination cartridge matched to that hazard.
What is the pack quantity for the D3076HF?
Sold as a 1-pair pack β€” two filters, one for each side of a Secure Click facepiece.
How does the D3076HF compare to the D3071?
Both are Secure Click P95 filters. The D3071 is general particulate only, with no hydrogen fluoride rating, and typically costs less. Buy the D3076HF only when your hazard assessment confirms hydrogen fluoride exposure.
Can I use the D3076HF on the FF-800 full-face respirator?
Yes. The FF-800 is a Secure Click full facepiece, and the D3076HF's push-to-connect mount seats on it the same way it does on the HF-800 half-facepiece.
When should I replace the D3076HF?
Replace it when damaged, soiled, or difficult to breathe through, or per your employer's written respiratory protection program change-out schedule β€” service life against hydrogen fluoride depends on concentration and exposure time, so don't rely on breathing resistance alone.