Honeywell North RU6500 full face respirator
EDITORIAL REVIEW: 4.5/5 WC Safety Review β the Honeywell North RU6500 full face respirator Editorial assessment by Steven Eaton, WC Safety editor, based on published Honeywell North specifications and category fit...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Editorial assessment by Steven Eaton, WC Safety editor, based on published Honeywell North specifications and category fit. We did not laboratory-test this product.
SHOP HONEYWELL NORTH FULL FACE RESPIRATORS β
Honeywell North RU6500 Full Face Respirator Overview
The Honeywell North RU6500 Full Face Respirator (SKU RU65002) uses an industrial mesh/nylon 4-point headnet, distinct from the 5-point strap harness on the sibling RU65001. As Honeywell North RU65002 mesh headnet respirator equipment, it's designed to be worn comfortably under a hard hat.
Safety note: this listing is the facepiece - cartridges and filters that determine your actual NIOSH approval number and hazard protection are typically sold separately and must be matched to your specific exposure. This North RU6500 hard hat compatible respirator is not rated for chemical splash hazard exposure by the facepiece alone; pair it with appropriate garments if splash risk is present. As a tight-fitting full facepiece respirator, it requires an initial and periodic fit test per OSHA 29 CFR 1910.134 to confirm a proper facial seal before relying on its rated protection factor.
As the RU6500 series full facepiece silicone design, it features a silicone facepiece and nose cup, a polycarbonate lens meeting ANSI Z87 for high impact, and a threaded cartridge connector. This Honeywell North full face respirator APF 50 carries the standard OSHA Assigned Protection Factor for tight-fitting full facepiece respirators. See our RU65002 vs RU65001 headnet vs strap comparison below, and check our best Honeywell North full face respirators guide for how it stacks up.
What It Is Built For
| Use case | Fit | Buyer guidance |
|---|---|---|
| Wearing under a hard hat | Strong fit | Mesh headnet design (RU65002) suited to this over a 5-point strap. |
| General respiratory protection with matched cartridges | Strong fit | Threaded connector accepts North-compatible cartridges/filters. |
| CF-SAR or PAPR system integration | Strong fit | Adaptable to side/front-mount configurations without re-fit-testing. |
| Ready-to-use protection without separate cartridges | Not included | This is the facepiece only - cartridges/filters sold separately. |
Pros & Cons
- Mesh headnet compatible with wearing a hard hat
- Silicone facepiece and nose cup for a comfortable seal
- ANSI Z87 polycarbonate lens for impact protection
- Threaded cartridge connector resists accidental disconnection
- Adaptable to CF-SAR/PAPR without separate fit testing
- Cartridges/filters not included - separate purchase required
- Requires an OSHA fit test before relying on the rated APF
- Different head harness (mesh) than the RU65001 5-point strap sibling
- Only 2 Judge.me reviews on record
How It Compares
Honeywell North also offers the 5400 series full face respirator and the 7600 series full face respirator, each with distinct features and price points - compare specs directly rather than assuming they match the RU6500 series. See our best full face respirator: 3M vs Honeywell guide for a cross-brand comparison. Browse the full Honeywell North full face respirators collection. Match a cartridge in the Honeywell North cartridge guide or how to choose a respirator cartridge, and see when do you need a respirator to confirm it fits your hazard.
Specifications
| Brand / Model | Honeywell North RU65002 (mesh headnet) |
| Protection factor | OSHA APF 50 (tight-fitting full facepiece) |
| Facepiece | Silicone, with silicone nose cup |
| Lens | Polycarbonate, ANSI Z87 high impact |
| Head harness | Industrial mesh/nylon headnet, hard-hat compatible |
| Sizes | Small, Medium, Large |
Related Respiratory Protection Resources
Honeywell North full face respirators Honeywell North 7600 series Honeywell North 5400 series best Honeywell North full face respirators best full face respirator: 3M vs Honeywell how to fit test a respirator OSHA 1910.134 respiratory protection respirator with glasses guide Honeywell North 5400 series full face respirator Honeywell North 7600 series full face respirator
Frequently Asked Questions
What is the difference between the RU65002 and RU65001?
The RU65002 uses an industrial mesh/nylon 4-point headnet designed to be worn under a hard hat. The RU65001 uses a 5-point strap harness instead. Both share the same silicone facepiece, lens, and cartridge connector - the head harness system is the main difference.
What is the Assigned Protection Factor (APF)?
As a tight-fitting full facepiece respirator, it carries the standard OSHA Assigned Protection Factor of 50. This applies to the complete assembled respirator with the correct cartridge or filter attached, not the bare facepiece alone.
Does this listing include cartridges or filters?
This listing is the facepiece. Cartridges and filters that determine your actual hazard protection and NIOSH approval number are typically sold separately - match them to your specific exposure before use.
What is the facepiece made of?
A silicone full facepiece with a silicone nose cup for facial seal and comfort, paired with a polycarbonate lens rated to meet ANSI Z87 for high-velocity impact protection.
Can I wear a hard hat with this respirator?
Yes. The mesh/nylon headnet design on the RU65002 is specifically intended to accommodate a hard hat worn over it, unlike a 5-point strap harness design that can be less compatible with certain hard hat styles.
Can this facepiece be used with a PAPR or supplied-air system?
Yes. The facepiece is adaptable to side-mount or front-mount CF-SAR (constant-flow supplied air) and PAPR configurations without requiring separate fit testing for each configuration. Confirm exact adapter and system compatibility before assembling a complete setup.
What sizes are available?
This listing covers the RU65002 in Small, Medium, and Large. Confirm your exact size using Honeywell's fit guidance before ordering, since a proper seal is essential for a tight-fitting respirator's rated protection factor.
How does the threaded cartridge connector work?
It secures cartridges and filters onto the facepiece with a threaded connection designed to prevent accidental disconnection during use, compared to simpler push-fit designs.
Do I need a fit test to use this respirator?
Yes. As a tight-fitting full facepiece respirator, it requires an initial and periodic fit test per OSHA 29 CFR 1910.134 to confirm a proper seal for your specific face shape.
What maintenance does the facepiece need?
Inspect the silicone seal, straps or headnet, lens, and cartridge connector before each use for cracks, tears, or damage, clean per Honeywell's guidance after use, and replace any worn components that could compromise the seal.
Can I use this for chemical splash protection?
The full facepiece and polycarbonate lens provide eye and face impact protection per ANSI Z87, but chemical splash protection depends on your complete PPE ensemble, not the respirator facepiece alone - pair it with appropriate chemical-resistant garments if splash exposure is a concern. See our OSHA respiratory protection reference for the full regulatory scope.
How is this different from the Honeywell North 5400 or 7600 series?
The 5400 and 7600 series are different Honeywell North full-face respirator lines with their own distinct features and price points. Compare specifications directly rather than assuming they share identical components with the RU6500 series. See our Honeywell North vs 3M respirators guide for cross-brand context.
Written by Steven Eaton, WC Safety Editorial β respiratory protection desk. Head-harness distinction and specifications independently verified against multiple industrial-supply retailers. Compare the range in Honeywell North full face respirators.
WC Safety is an independent PPE review site; no paid placement. Fit-test and match cartridges to your specific hazard before relying on this respirator.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.