Dräger X-plore P100 Particulate Filter — 20-Pack, NIOSH-Approved (6738350)
EDITORIAL REVIEW: 4.7/5 WC Safety Review — the Dräger X-plore P100 Particulate Filter Editorial assessment by the WC Safety Editorial Team, based on published Dräger specifications and the NIOSH filter classes. We...
Check Price on Amazon🔒 Amazon Associate · You pay the same price · We earn a small commission
Editorial assessment by the WC Safety Editorial Team, based on published Dräger specifications and the NIOSH filter classes. We did not laboratory-test this product.
SHOP P100 FILTERS →SHOP FILTERS & CARTRIDGES →
Dräger X-plore P100 Particulate Filter Overview
The Dräger X-plore P100 Particulate Filter (6738350) is a NIOSH-approved P100 filter supplied 20 to a pack. P100 means it captures at least 99.97% of airborne particles and is oil-proof, so it handles dust, mists, fumes, and oil-based particulates. It is a bayonet pancake filter that fits Dräger X-plore respirators only.
As the Dräger 6738350, this X-plore Pure P100 filter is a low-profile P100 pancake filter. It is a NIOSH P100 particulate filter and an X-plore bayonet filter for Dräger half and full facepieces.
It fits the Dräger X-plore 3300 and 3500 half masks and the X-plore 5500 full facepiece — not other brands, because filter connections are not universal. It filters particles only; for gases, pair it with a gas cartridge, as covered below. Use it with the X-plore 3300 half mask or the X-plore 5500 full facepiece, learn the class in best P100 filter comparison, and browse the range in P100 respirator filters.
What This Filter Is For
| Use case | Fit | Buyer guidance |
|---|---|---|
| Dust, mists, and fumes | Purpose-built | P100 captures 99.97% of particles. |
| Oil-based particulate | Strong | P is oil-proof, unlike N or R. |
| Dräger X-plore respirators | Purpose-built | 3300, 3500, and 5500 bayonet only. |
| Gases or vapors | Add a cartridge | Particulate only; needs gas media. |
| Other-brand respirators | Not compatible | Does not fit 3M or North. |
A filter is only part of a respirator, and it only removes what it is rated for. This P100 captures particulate, but it does not protect against gases or vapors, and it does not add oxygen. An air-purifying respirator cannot be used in an oxygen-deficient or IDLH atmosphere; those require a supplied-air respirator or a self-contained breathing apparatus (SCBA). Use the filter only on a fit-tested Dräger X-plore facepiece, with a medical clearance and a clean-shaven seal, within an OSHA 29 CFR 1910.134 respiratory-protection program, and change filters on schedule or when breathing gets harder. For organic vapor, acid gas, or other gases, add an X-plore gas or combination cartridge matched to your hazard. Learn more in are respirator cartridges universal and P95 vs P100 filters.
Pros & Cons
- NIOSH P100: 99.97% and oil-proof
- Low-profile pancake style; good visibility
- Bayonet fit for X-plore 3300/3500/5500
- Can pair with a gas cartridge via adapter
- 20-pack (ten pairs) for stock
- Particulate only; no gas or vapor
- Fits Dräger X-plore only, not other brands
- No protection without a fit-tested facepiece
- Not the nuisance-odor version
How It Compares
The X-plore Pure P100 is a brand-specific particulate filter. Weigh it against nearby options:
| Option | Protection | Fits | Best for |
|---|---|---|---|
| X-plore Pure P100 (this page) | P100 particulate | X-plore 3300/3500/5500 | Dust, mist, fume on Dräger masks |
| X-plore OV/P100 combination | Organic vapor + P100 | X-plore 3300/3500/5500 | Vapor plus particulate |
| X-plore multi-gas/P100 | Multi-gas + P100 | X-plore 3300/3500/5500 | Multiple gases plus particulate |
Choose the Pure P100 for particulate only, the X-plore OV/P100 combination for vapor plus particles, or the multi-gas/P100 for several gases. See best P100 filter comparison, P95 vs P100, and are cartridges universal.
Specifications
| Brand / Part | Dräger X-plore Pure P100 (6738350) |
| Class | NIOSH P100 (99.97%, oil-proof), particulate only |
| Style / mount | Low-profile pancake; X-plore bayonet connection |
| Fits | Dräger X-plore 3300, 3500 half masks; X-plore 5500 full facepiece |
| Pack | 20 filters (10 pairs) |
| Note | Pure P100 (not the nuisance-odor version); can add gas media via adapter |
Related Guides
best P100 filter comparison, P95 vs P100 filters, are respirator cartridges universal, best multi-gas P100 cartridge, best OV/P100 cartridge.
Related Resources
P100 respirator filters respirator filters and cartridges combination cartridges X-plore 3300 half mask X-plore 5500 full facepiece
Frequently Asked Questions
What does P100 mean on this filter?
P100 is the highest particulate filter class: it captures at least 99.97% of airborne particles and is oil-proof, so it works against oil-based and non-oil particulates such as dust, mists, and fumes. It filters particles only, not gases or vapors.
Which respirators does the X-plore P100 fit?
It is a bayonet filter that fits Dräger X-plore 3300 and 3500 half masks and the X-plore 5500 full facepiece. It does not fit 3M, Honeywell North, Moldex, or other brands, because respirator filter connections are not universal.
Does it protect against gases or vapors?
No. This is a particulate-only P100 filter. For organic vapor, acid gas, or other gases, use a Dräger X-plore gas cartridge or a combination cartridge such as the OV/P100 or multi-gas/P100, matched to your specific hazard.
Is it NIOSH-approved?
Yes, it is NIOSH-approved as a P100 filter, but NIOSH approval applies to the complete assembly of an approved X-plore facepiece with approved filters. Use it only with the X-plore respirators and components listed on its approval.
How many filters are in the pack?
This is a 20-pack, or 10 pairs, of the Pure P100 pancake filter. Filters are used in pairs on a half mask or full facepiece, so a 20-pack gives ten sets before you reorder.
Is this the Pure P100 or the odor version?
This is the Pure P100 (part 6738350). Dräger also makes a Pure P100 with nuisance-odor relief under a different part number, so confirm the part number if you specifically want or do not want the odor layer.
When should I replace the filter?
Replace P100 filters when breathing becomes harder, on your program's schedule, or if a filter is damaged, wet, or clogged. Particulate filters load up over time, and a clogged filter increases breathing resistance; follow the change schedule in your respiratory-protection program.
Can I use one filter alone for protection?
No. A filter is only part of a respirator. You need a fit-tested X-plore facepiece, a medical clearance, and a clean-shaven seal, all within an OSHA 1910.134 respiratory-protection program. The filter does nothing without the mask.
What is a pancake filter?
Pancake filters are thin, low-profile particulate filters that sit close to the facepiece for a compact fit and good visibility. The X-plore Pure P100 is this style and mounts with the X-plore bayonet connection.
Can I combine it with a gas cartridge?
The X-plore Pure P100 can pair with an X-plore bayonet gas cartridge using the X-plore Pure adapter to make a combined filter, or you can buy a ready-made X-plore combination cartridge. Match the gas media to your hazard and confirm the setup.
Is it good for welding fume?
A P100 captures welding-fume particulate, which is why it is used in metalworking. But welding can also release gases and can deplete oxygen in a confined space, so assess the full hazard and add gas media or supplied air where needed.
How do I store the filters?
Keep unused filters sealed in their packaging in a clean, dry place away from contaminants, and do not use a filter past its shelf life. Once opened and used, a filter starts loading, so track its service life.
Written by Steven Eaton, WC Safety Editorial. Specifications sourced from Dräger published data and the NIOSH filter classes. Compare the range in P100 respirator filters.
WC Safety is an independent PPE retailer; no paid placement. A filter protects only on a fit-tested facepiece within a respiratory-protection program, and only against the particulate it is rated for; match a supplied-air system to any atmosphere that is unsafe to filter.