Skip to content
Industrial Safety Equipment & PPE β€” ANSI/OSHA Compliant
Industrial Safety Equipment & PPE β€” ANSI/OSHA Compliant
Home β€Ί 3M Respirator Filters and Cartridges β€Ί 3M Secure Click D80926 Multi-Gas/Vapor P100 Com...

3M Secure Click D80926 Multi-Gas/Vapor P100 Combination Cartridge, 1 Pair

3M SKU: D80926 Respirator Cartridge
β˜… β˜… β˜… β˜… β˜… 4.8 (403 reviews on WC Safety)
$46.95
Final price set by Amazon Β· may vary

WC Safety Editorial: The 3M Secure Click D80926 is the maximum-coverage combination cartridge in the Secure Click line β€” OV, acid gases, ammonia, formaldehyde, and P100 particulate in a single push-click housing...

Check Price on Amazon

πŸ”’ Amazon Associate Β· You pay the same price Β· We earn a small commission

Zero Sponsored ListingsNo paid placements. Every recommendation is based on compliance, build quality, and field performance.
Curated SelectionExpert-chosen safety gear
Independently ReviewedUnbiased assessments β€” no manufacturer input
Built for Industrial BuyersSourced and reviewed for safety managers, procurement teams, and field supervisors.
3m Acid Gas Combination Cartridge Formaldehyde h2s hf-800 Multi Gas NIOSH Approved
WC Safety Editorial: The 3M Secure Click D80926 is the maximum-coverage combination cartridge in the Secure Click line β€” OV, acid gases, ammonia, formaldehyde, and P100 particulate in a single push-click housing. Justified when your documented hazard profile requires it; over-specified when it does not. Read the full D80926 review (4.5/5) β†’ Β Β·Β  Compare all Secure Click filters & cartridges β†’

3M Secure Click D80926 Multi-Gas P100 Combination Cartridge β€” Maximum Secure Click Coverage, 1 Pair

The 3M Secure Click D80926 multi-gas P100 combination cartridge is the highest-coverage combination cartridge in the Secure Click D-series β€” the only Secure Click option that pairs full multi-gas vapor coverage (organic vapors, acid gases, ammonia, methylamine, formaldehyde) with an integrated oil-resistant P100 filter (99.97% at 0.3Β Β΅m). Sold as 1 pair per pack. Fits 3M HF-800 (APF 10) and FF-800 (APF 50) Secure Click facepieces. The D80926 is justified when your documented hazard profile requires all of those chemical classes simultaneously or interchangeably β€” wastewater treatment spray, pesticide application, formaldehyde spray environments, or multi-hazard crews needing one cartridge SKU across variable chemical assignments.

Features Β |Β  Specs Β |Β  Compatibility Β |Β  Comparison Β |Β  FAQ

The 3M Secure Click D80926 is a NIOSH-approved TC-23C combination cartridge rated for organic vapor, acid gas (Cl2, HCl, SO2, HF), ammonia (NH3), methylamine (CH3NH2), formaldehyde (HCHO), and P100 particulate β€” the widest single-cartridge chemical coverage available on 3M's Secure Click HF-800 and FF-800 respirator platform.

Key features β€” 3M Secure Click D80926 multi-gas P100 combination cartridge

Specifications β€” 3M Secure Click D80926

Attribute Value
SKU / Model 3M D80926
NIOSH Approval TC-23C β€” Combination Cartridge (OV/CL/HC/SD/SH/P100), 42 CFR Part 84 Subpart L
Protection Classes Organic Vapors Β· Acid Gases (Cl2, HCl, SO2, HF) Β· Ammonia (NH3) Β· Methylamine (CH3NH2) Β· Formaldehyde (HCHO) Β· P100 Particulate (99.97%, oil-resistant)
Particulate Efficiency 99.97% at 0.3 Β΅m (P100, oil-resistant per 42 CFR 84 Subpart K)
Mount System 3M Secure Click positive-lock (HF-800 and FF-800 facepieces only)
Compatible Facepieces 3M HF-801, HF-802, HF-803 (APF 10) Β· 3M FF-800 series (APF 50)
Not Compatible With 3M 6000, 6500, 7000, 7500, 7800S bayonet respirators (use 3M 60926 instead)
Pack Contents 1 pair (2 cartridges)
ESLI None β€” documented change-out schedule required per OSHA 1910.134(d)(3)(iii)(B)
Bayonet Equivalent 3M 60926 (for 6000/7000 series bayonet facepieces)
Brand 3M

Primary use cases β€” when to order the 3M D80926

What respirators does the 3M D80926 fit? β€” Secure Click compatibility

The 3M Secure Click D80926 multi-gas P100 combination cartridge is compatible exclusively with Secure Click platform facepieces. It uses the Secure Click push-and-click positive-lock mount, which is physically incompatible with the twist-and-lock bayonet port on 3M 6000, 6500, 7000, 7500, and 7800S respirators. One D80926 pair fits every Secure Click facepiece:

Facepiece Type Size OSHA APF
3M HF-801 Half-face (Secure Click) Small 10
3M HF-802 Half-face (Secure Click) Medium 10
3M HF-803 Half-face (Secure Click) Large 10
3M FF-800 series Full-face (Secure Click) S / M / L 50

For many D80926 applications β€” wastewater treatment, chemical processing, refrigeration maintenance β€” the FF-800 full-face at APF 50 is the more appropriate platform than the HF-800 half-face at APF 10. Multi-gas environments with ammonia or acid gas concentrations that may be variable or elevated during peak operations benefit from the additional protection margin and the full-face splash protection the FF-800 provides against acid aerosol and ammonia mist. The D80926 cartridge is identical for both facepiece types β€” facepiece choice is driven by your air monitoring data and exposure assessment.

For users on bayonet-mount 3M respirators (6000, 7000 series), the equivalent is the 3M 60926 multi-gas combination cartridge. The D80926 Secure Click cartridge is not physically compatible with bayonet facepieces. See the 3M Secure Click platform guide for platform comparison details.

For programs running particulate-only task rotations on the same Secure Click facepiece fleet, the 3M Secure Click D3091 P100 filter or the D9093 P100 hard case filter may be more cost-effective than running a D80926 for particulate-only segments.

3M Secure Click platform β€” donning, doffing, and installation guidance

3M official guidance for the Secure Click respirator platform. Fit testing per OSHA 29 CFR 1910.134(f) is required for every assigned worker regardless of cartridge selection.

3M Secure Click D80926 vs D80923 vs D8006 β€” which multi-gas combination cartridge do you need?

3M Secure Click D80926 β€” combination cartridge comparison
Cartridge OV Acid Gas NH3/HCHO P100 Best for
3M D80926 βœ“ βœ“ βœ“ βœ“ Max coverage β€” OV + AG + NH3 + HCHO + P100
3M D80923 βœ“ βœ“ β€” βœ“ OV + acid gas + P100; no NH3 or HCHO (step down when NH3 absent)
3M D8006 βœ“ βœ“ βœ“ β€” Multi-gas vapor (OV + AG + NH3 + HCHO); no spray aerosol/P100
3M D80921 βœ“ β€” β€” βœ“ OV + P100 only β€” spray paint, non-acid solvents (lowest cost OV combo)

When to choose the D80926: your hazard assessment confirms organic vapors, acid gases, AND ammonia or formaldehyde, alongside spray aerosol or airborne particulate. All four chemical classes must be present to justify the D80926's cost premium.

When to step down to the D80923: ammonia and formaldehyde are absent from your SDS β€” the D80923 covers OV + acid gas + P100 at lower cost when multi-gas coverage is not needed. Read the D80923 editorial review for the side-by-side evaluation.

When to choose the D8006 instead: you face multi-gas vapor exposure (including ammonia or formaldehyde) but no spray aerosol or particulate hazard β€” the D8006 covers the full multi-gas vapor profile at a lower cost than the D80926 when P100 is not needed.

Browse the complete 3M respirator filters and cartridges collection and consult the 3M Secure Click cartridge selection guide to map your SDS hazard list to the correct D-series cartridge.

Frequently asked questions β€” ordering the 3M Secure Click D80926

Is the D80926 sold as 1 pair or a single cartridge β€” what is included?

The 3M Secure Click D80926 is sold as a 1-pair pack containing 2 cartridges β€” one for the left port and one for the right port of the HF-800 or FF-800 facepiece. Both cartridges are installed and replaced together as a matched pair. Never run a dual-cartridge respirator with one fresh and one spent cartridge β€” total protection is limited by the more exhausted unit.

How many pairs of D80926 cartridges do I need per worker per month?

Monthly quantity depends on your calculated change-out interval for the most limiting contaminant in your documented hazard profile. In multi-gas environments (ammonia, formaldehyde, acid gases), run 3M's Chemical Cartridge Service Life Estimation Software separately for each documented chemical at your measured concentration and relative humidity. Apply the most conservative (shortest) result as your replacement interval. For ammonia-heavy environments at elevated concentrations, daily or even multiple-per-shift replacement is possible. Contact your industrial hygienist before purchasing program quantities to ensure your stocking level matches your calculated interval.

Which size Secure Click respirator facepiece should I pair with the D80926?

The D80926 cartridge is facepiece-size-independent β€” it fits the 3M HF-801 (small), 3M HF-802 (medium), and 3M HF-803 (large) half-face respirators, and the 3M FF-800 full-face (all sizes). Facepiece size selection is based on your worker's fit test result per OSHA 29 CFR 1910.134(f). For wastewater and chemical processing applications, the FF-800 full-face is frequently the appropriate platform at APF 50 β€” evaluate both facepiece options with your industrial hygienist.

Does the D80926 require any additional filter components to install?

No. The 3M Secure Click D80926 is a self-contained combination cartridge. The full multi-gas sorbent assembly and the P100 filter element are integrated in a single housing β€” no separate filter disc, adapter, or retainer is required. Press each cartridge firmly onto the facepiece Secure Click port until the audible click confirms full engagement. No tools, no assembly, no additional components.

Can I use D80926 cartridges as the single standard cartridge for a crew working multiple chemical exposure tasks?

Yes β€” this is one of the D80926's documented justification scenarios. When a crew rotates through tasks where the collective documented hazard range spans OV, acid gas, ammonia or formaldehyde, and spray particulate, specifying a single D80926 SKU eliminates field selection errors during shift changes and task rotations. Before adopting this approach, verify that ammonia or formaldehyde are genuinely present in at least some of the crew's documented task hazards β€” if neither is present, the D80923 provides equivalent protection at lower cost per pair. Consult a Certified Industrial Hygienist (CIH) when designing multi-SKU vs single-SKU respiratory protection programs.

Is the D80926 the correct cartridge for ammonia refrigeration maintenance with aerosol spray?

Yes β€” anhydrous ammonia and ammonia refrigerant systems create acute NH3 exposure that may combine with organic refrigerant oil aerosol and aerosol from spray testing or cleaning operations. The D80926's OV + acid gas + ammonia + P100 coverage profile addresses this documented combination hazard. For high-concentration ammonia release events above 10Γ— the OSHA PEL (OSHA PEL for ammonia: 50 ppm TWA), the FF-800 full-face with D80926 at APF 50 is more appropriate than the HF-800 half-face. Above 50Γ— PEL, a supplied-air respirator is required. Browse the 3M cartridge collection for compatible facepieces.

What is the bayonet-system equivalent of the D80926 for workers on 3M 6000 or 7000 series respirators?

The functional equivalent for 3M 6000, 6500, 7000, 7500, and 7800S bayonet respirators is the 3M 60926 multi-gas combination cartridge β€” same protection profile (OV + AG + NH3 + CH3NH2 + HCHO + P100), bayonet mount. The D80926 Secure Click cartridge is physically incompatible with bayonet facepieces β€” no adapter exists. Switching to the D80926 requires upgrading to a Secure Click facepiece (HF-800 or FF-800). See the 3M Secure Click platform guide for migration considerations.

Should I order the D80926 or the D80923 for a pesticide spray program β€” which covers more?

Order the D80926 if your pesticide formulations include ammonia-based active ingredients or adjuvants β€” the D80923 does not cover ammonia. If your pesticide SDS lists only organic solvent carriers and acid gas components without ammonia or formaldehyde, the D80923 is the more targeted and cost-effective specification. Additionally, check whether your EPA pesticide label specifies a minimum respirator APF β€” some labels require a full-face respirator, which means the FF-800 with D80926 (APF 50) rather than the HF-800 (APF 10). Verify both the SDS and the pesticide label before selecting a cartridge.

How does OSHA's formaldehyde standard (29 CFR 1910.1048) affect cartridge selection when ordering the D80926?

OSHA 29 CFR 1910.1048 governs formaldehyde exposure in general industry. The D80926's formaldehyde sorbent satisfies the respiratory protection component of a compliant formaldehyde program for exposures within the cartridge's rated APF range. However, the standard also requires exposure monitoring, medical surveillance, and a written exposure control plan that apply independently of cartridge selection. Confirm your measured formaldehyde concentration against the OSHA action level (0.5 ppm TWA) and STEL (2 ppm), then calculate change-out intervals using 3M's service life software at your documented concentration. The D80926 alone does not constitute a complete 1910.1048 compliance program.

Is the D80926 compatible with the Secure Click D3091 P100 filter on the same facepiece fleet?

Yes β€” the 3M Secure Click D3091 P100 filter and the D80926 cartridge use the same Secure Click mount and are both compatible with HF-800 and FF-800 facepieces. Programs that run multi-gas combination tasks (D80926) alongside particulate-only tasks (D3091) can do so on the same facepiece fleet β€” workers swap the appropriate cartridge or filter for each task segment. Ensure your written respiratory protection program documents both the D80926 and D3091 as approved cartridges for the respective tasks, with separate change-out schedules for each.

Can I order the D80926 for a wastewater spray task where I currently use the D8006?

Yes β€” and this is the correct upgrade path. The D8006 covers the full multi-gas vapor profile (OV + acid gas + ammonia + formaldehyde) but includes no P100 particulate filtration. When spray equipment in your wastewater operation generates aerosol alongside the multi-gas vapor exposure, the D80926 is the correct step up β€” adding P100 particulate filtration without removing any of the D8006's gas-phase coverage. No facepiece change is required; both the D8006 and D80926 use the same Secure Click mount. Update your written program and change-out schedule documentation when switching.

Does the D80926 provide adequate protection for both the HF-801 small and HF-803 large facepiece sizes?

Yes. The 3M Secure Click D80926 fits all three HF-800 half-face sizes β€” 3M HF-801 (small), 3M HF-802 (medium), and 3M HF-803 (large) β€” and the FF-800 full-face. The cartridge housing and filter media are identical across all facepiece size combinations. A single D80926 part number covers the entire Secure Click facepiece fleet, which simplifies inventory management for programs with workers wearing multiple facepiece sizes. Order the correct facepiece size based on each worker's fit test result; the D80926 cartridge pair is the same regardless.

Order the 3M Secure Click D80926 multi-gas P100 combination cartridge

The 3M Secure Click D80926 multi-gas P100 combination cartridge is the maximum-coverage specification for wastewater spray, pesticide application, formaldehyde environments, refrigeration maintenance, and multi-hazard programs on the Secure Click platform. Sold as 1 pair per pack. Fits HF-800 and FF-800 Secure Click facepieces. Ships from WC Safety.

ADD TO CART β€” WC SAFETY β†’ CHECK PRICE ON AMAZON β†’

As an Amazon Associate, WC Safety earns from qualifying purchases. Full affiliate disclosure.

Why trust this 3M Secure Click D80926 page? WC Safety operates as an independent industrial PPE retailer β€” we stock and sell the D80926, the full Secure Click D-series, and compatible HF-800 and FF-800 facepieces to safety managers, procurement teams, and field supervisors. Specs on this page are cross-referenced against the NIOSH 42 CFR Part 84 Subpart L combination cartridge approval (TC-23C) on the NIOSH Certified Equipment List, the 3M D80926 Technical Data Sheet, OSHA 29 CFR 1910.134, OSHA 29 CFR 1910.1048 (formaldehyde), and ANSI/ASSE Z88.2-2015. Disclosed: WC Safety stocks this product and earns Amazon affiliate commissions on outbound clicks; neither factor influences the specs or recommendations shown.
Curated by WC Safety Editorial β€” Industrial respiratory protection desk Β· specialization: NIOSH-approved multi-gas combination cartridges, Secure Click platform selection, and chemical-specific respiratory protection program design.
Last updated: Β· Sources reviewed: NIOSH 42 CFR 84 Subpart L (TC-23C), OSHA 29 CFR 1910.134, OSHA 29 CFR 1910.1048 (formaldehyde), NIOSH NPPTL Certified Equipment List, 3M D80926 Technical Data Sheet, ANSI/ASSE Z88.2-2015, EPA pesticide label respiratory requirements.
Editorial standard: Zero sponsored listings. No manufacturer input. No paid placement on this page. Specs independently verified against the NIOSH approval certificate.
How this 3M Secure Click D80926 page is maintained
Primary sources: (1) NIOSH 42 CFR Part 84 Subpart L β€” TC-23C combination cartridge approval criteria; (2) OSHA 29 CFR 1910.134 β€” respiratory protection program requirements, APF table, change-out schedule mandate; (3) OSHA 29 CFR 1910.1048 β€” formaldehyde standard and respiratory protection requirements; (4) NIOSH NPPTL Certified Equipment List β€” TC-23C category verification; (5) 3M Technical Data Sheet for the D80926 Multi-Gas Combination Cartridge β€” chemical approval list, compatibility specifications; (6) ANSI/ASSE Z88.2-2015 β€” practices for respiratory protection programs. Page reviewed on every change to NIOSH guidance, OSHA standards, or 3M D80926 technical specifications.
Disclosures & editorial standards
WC Safety participates in the Amazon Services LLC Associates Program. Outbound Amazon links use partner tag wcsafety04-20 and carry rel="sponsored nofollow noopener". WC Safety stocks the 3M Secure Click D80926 and compatible Secure Click respirators. We accept no manufacturer payment, sponsorship, or product samples. This page reflects independent editorial judgment. This content is not medical, legal, or regulatory advice. Respirator selection is governed by applicable OSHA standards, your facility's written respiratory protection program, and industrial hygienist assessment of your specific exposures. Consult a Certified Industrial Hygienist (CIH) for exposure-specific program design.
Brand / Vendor
3M
Model / SKU
D80926
Product Type
Respirator Cartridge
Price
$46.95 (Amazon)
Rating
4.8 / 5 β€” 403 reviews
Availability
βœ“ In Stock on Amazon
🏷️
No Paid Placements
Every product earns its place based on safety credentials and field performance, not advertising spend.
🏭
Industrial Grade Only
Products sourced for professional use in manufacturing, construction, and industrial environments.
πŸ”¬
Compliance Verified
Every product listed on WC Safety is reviewed for standards compliance and safety credentials before publication.
🏭
Sourced for Professionals
Gear selected for safety managers, procurement teams, and field supervisors β€” not casual consumers.
Share Your Experience

Write a Review

Select a rating
βœ“

Thank you for your review!

Your submission has been received and will be published after verification.

3M Secure Click D80926 Multi-Gas/Vapor P100 Combination Cartridge, 1 Pair