GVS Elipse Half Mask Respirator β P100, Low-Profile S/M (SPR451)
EDITORIAL REVIEW: 4.6/5 WC Safety Review β the GVS Elipse Half Mask Respirator Editorial assessment by the WC Safety Editorial Team, based on GVS published specifications and the NIOSH particulate filter classes. ...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Editorial assessment by the WC Safety Editorial Team, based on GVS published specifications and the NIOSH particulate filter classes. We did not laboratory-test this product.
SHOP HALF-MASK RESPIRATORS βP100 FILTERS β
GVS Elipse Half Mask Respirator Overview
The GVS Elipse Half Mask Respirator (SPR451) is a NIOSH-approved P100 half mask in the low-profile Small/Medium size, capturing at least 99.97% of airborne particles with a latex- and silicone-free medical-grade TPE facepiece.
As the GVS Elipse SPR451, this GVS SPR451 is a P100 half mask respirator and a low profile P100 respirator β a genuinely latex-free half mask respirator for dust and mist.
It ships with replaceable P100 filters, uses a large central non-return valve for easier breathing, adjusts with a 4-position strap, and carries a five-year shelf life. It is particulate-only as shipped; for gases, fit GVS OV/P100 or multigas filters. The larger Medium/Large size is the SPR457. Learn more in best half-face respirator and are respirator cartridges universal.
Who It Is For
| Use case | Fit | Buyer guidance |
|---|---|---|
| Dust, mist & metal fume | Purpose-built | P100: 99.97% efficiency. |
| Smaller faces (S/M) | Purpose-built | SPR451 is Small/Medium. |
| Latex-sensitive workers | Strong | Latex- and silicone-free TPE. |
| Larger faces | Choose M/L | Use the SPR457 (M/L). |
| Gases or vapors | Change filters | Fit GVS OV/P100 or multigas. |
This respirator protects only within limits. Its P100 filters remove particulate, but they do not remove gases or vapors as shipped, and no respirator adds oxygen, so no air-purifying respirator like this one may be used in an oxygen-deficient or IDLH atmosphere β those require a supplied-air respirator or a self-contained breathing apparatus (SCBA). It only works on a fit-tested, clean-shaven face with medical clearance under an OSHA 29 CFR 1910.134 program, and you run a user seal check each time. For organic vapor or acid gas, fit GVS Elipse OV/P100 or multigas filters rather than assuming the P100 covers gases, and use only GVS Elipse filters so the NIOSH approval stays valid. See best P100 filter comparison and P95 vs P100.
Pros & Cons
- NIOSH P100: 99.97% particulate
- Low-profile with a wide field of view
- Latex- and silicone-free medical TPE
- Central valve; 4-position strap
- Five-year shelf life; replaceable filters
- Particulate only as shipped
- GVS-specific filters, not universal
- No eye protection (half mask)
- Not for IDLH or oxygen-deficient air
How It Compares
The SPR451 is the S/M base Elipse half mask. Weigh it against nearby GVS options:
| Option | Size / Type | Eye protection | Best for |
|---|---|---|---|
| Elipse SPR451 (this page) | S/M, P100 half mask | None (add glasses) | Smaller faces, low profile |
| Elipse SPR457 | M/L, P100 half mask | None (add glasses) | Larger faces |
| Elipse Integra | P100 half mask | Integrated goggle | Combined eye + lung |
Choose the GVS Elipse Half Mask Respirator in S/M, the SPR457 in M/L, or the Elipse Integra for a built-in goggle. Compare in best half-mask respirators.
Specifications
| Brand / Model | GVS Elipse SPR451 (Small/Medium) |
| Approval / Class | NIOSH P100 (TC-84A-6949), 99.97% at 0.3Β΅m; particulate only |
| Facepiece | Medical-grade TPE; latex-, silicone-, odor-free; ~100 x 130 mm |
| Valve / Strap | Large central non-return valve; 4-position adjustable strap |
| Filters / Life | Replaceable Elipse P100 filters; 5-year shelf life |
| For gases | Fit GVS OV/P100 or multigas filters (sold separately) |
Related Guides
Best half-face respirator, best P100 filter comparison, are respirator cartridges universal, P95 vs P100 filters, best half-mask respirators.
Related Resources
Half-mask respirators P100 filters GVS Elipse SPR457 (M/L) Elipse SPR321 P100 filters Elipse Integra (goggle)
Frequently Asked Questions
How do I choose between the S/M (SPR451) and the M/L (SPR457)?
The SPR451 is the Small/Medium size and the SPR457 is the Medium/Large. Choose by the size that seals evenly on your face without gaps or pressure points. If you are between sizes, a fit test on each is the reliable way to decide.
What are the mask's dimensions?
The facepiece is compact, roughly 100 mm wide by 130 mm tall in the Small/Medium size, with a low-profile shape that keeps a wide field of view. Its flexible medical-grade TPE conforms to the face for the seal a respirator depends on.
What is the shelf life of the mask and filters?
GVS states a five-year storage life for the mask and filters when kept sealed and within their conditions. Note when you put a mask or filter into service, and do not use one past its shelf life or your program's change schedule.
Is the SPR451 facepiece reusable?
Yes. The facepiece is reusable; you replace only the P100 filters when they load up, are damaged, or reach your change schedule. Maintaining the facepiece and swapping filters is more economical over time than a fully disposable respirator.
What is the mask made of?
It is a medical-grade thermoplastic elastomer (TPE) that is latex-free, silicone-free, and odor-free. That helps workers with latex sensitivities, avoids silicone where it is not wanted, and keeps the flexible seal comfortable over a shift.
Does the low-profile design block my vision?
The Elipse is designed to sit low on the face and keep a full field of vision, which is one reason it suits work needing good downward and peripheral sight. It still must seal fully, so fit takes priority over the low profile.
Can I share the mask between workers?
A tight-fitting respirator should be personal-issue and fit-tested to the individual. Do not casually share a mask between workers; if a mask must be reassigned, clean and disinfect it per the instructions and fit-test the new user.
Does the central valve help in humid or wet work?
Yes. The large central non-return exhalation valve lowers breathing resistance and reduces moisture build-up, and the non-slip 4-position strap is made to stay put in humidity or wet conditions, which helps comfort on hot, damp jobs.
Can I use the SPR451 in an oxygen-deficient or confined space?
No. A respirator purifies air but adds no oxygen. A confined space or a low-oxygen or immediately hazardous atmosphere needs a supplied-air system or a self-contained breathing apparatus, plus confined-space entry procedures, not an air-purifying half mask.
Are the filters GVS-specific?
Yes. The Elipse uses GVS Elipse filters only, not 3M, Honeywell, or Moldex media, because the fit and the NIOSH approval are specific to the assembly. Using the wrong filter voids the approval and the protection.
How do I store the mask between shifts?
Wipe it per the GVS instructions, let it dry, and store it clean and dry in a bag or container out of direct sunlight so the seal is not distorted. Inspect the valve, seal, and filters before each use.
Can I add gas protection to the SPR451?
As shipped it is P100 particulate only. For organic vapor or multigas exposure, fit GVS Elipse OV/P100 or multigas filters in place of the P100 filters, matched to your specific hazard; a P100 alone does not remove gases.
Written by Steven Eaton, WC Safety Editorial. Specifications sourced from GVS published data and the NIOSH particulate filter classes. Compare the range in half-mask respirators.
WC Safety is an independent PPE retailer; no paid placement. A respirator protects only on a fit-tested face within a respiratory-protection program and only against what its filters are rated to capture; use supplied air where the air is unsafe to filter.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.