Forensics 4 Gas Wall-Mount Monitor — CO, H2S, O2 & LEL (Relay Output)
Editor’s note: the Forensics 4 gas wall-mount monitor is one of the instruments we curate in our Fixed Gas Detection Systems buyer’s hub. Compare it with the Forensics EX/LEL Wall-Mount below before you order. For...
Check Price on Amazon🔒 Amazon Associate · You pay the same price · We earn a small commission
Forensics 4 Gas Wall-Mount Monitor — Fixed CO, H2S, O2 & LEL
The Forensics 4 gas wall-mount monitor reads CO, H2S, O2 and combustible LEL from a single fixed head — a fixed gas detection system that covers all four atmospheric hazards continuously and drives ventilation or shutdown through its relay output.
Jump to: Features · Specs · What it detects · Comparison · FAQ
The Forensics 4 Gas Wall-Mount Monitor is a fixed, continuously-monitoring detector for CO, H2S, O2 and combustible LEL, with relay output and NIST-traceable calibration.
Key features
- Monitors all four atmospheric hazards — CO, H2S, O2 and combustible LEL — from one fixed head
- Continuous wall-mounted coverage of an unattended space
- Relay output drives ventilation, alarms or shutdown
- Adjustable audible and visual alarms per gas
- USA NIST-traceable calibration
- The all-in-one fixed solution where several gases are a risk
- Four gases from one fixed head
- Continuous unattended monitoring
- Relay output for ventilation/shutdown
- NIST-traceable calibration
- Simplifies multi-gas install
- Highest cost in the Forensics fixed family
- Single point coverage
- Hard-wired install required
- Not portable
Specifications
| Specification | Detail |
|---|---|
| Gases detected | CO, H2S, O2, EX (LEL) combustibles |
| Mounting | Wall-mount, fixed |
| Monitoring | Continuous (always on) |
| Output | Relay output + adjustable sound & light alarms |
| Calibration | USA NIST-traceable |
| Enclosure | Industrial |
| Weight | 3 lb |
Where the Forensics 4 Gas Wall-Mount Monitor fits
- Wastewater and pump stations
- Confined or below-grade plant rooms
- Parking and loading areas (CO)
- Digesters and tanks (H2S, O2)
- Any space with multiple gas hazards
What the Forensics 4 Gas Wall-Mount Monitor detects (and what it doesn’t)
This monitor covers CO, H2S, O2 and combustible LEL — the four atmospheric hazards — but not VOCs, CO2 or specific toxics like chlorine. For a single combustible point use the Forensics EX LEL Detector; for hydrogen the Hydrogen Detector. Mount it considering each gas’s density and the room layout, and tie the relay into ventilation or shutdown. It protects the installed space; entrants still need a Portable Gas Detectors instrument for pre-entry testing and a Personal & Wearable Gas Detectors clip during work.
Cross-shopping? This unit sits in our Fixed Gas Detection Systems hub alongside Forensics EX/LEL Wall-Mount, Forensics Hydrogen Wall-Mount, Macurco PM100-CO, Macurco GBC-24-2. For other gas-detection form factors see Portable Gas Detectors, Personal & Wearable Gas Detectors, Area & Transportable Gas Monitors, or browse the full Gas Detectors range.
Forensics fixed wall-mount family compared
| Model | Gas(es) | Range | Output | Street price |
|---|---|---|---|---|
| EX LEL Detector | Combustibles (EX) | 0-100% LEL | Relay + alarms | ~$599 |
| Hydrogen Detector | Hydrogen (H2) | 0-1000 ppm | Relay + alarms | ~$799 |
| 4 Gas Monitor | CO, H2S, O2, EX LEL | Multi-gas | Relay + alarms | ~$1,395 |
- Choose the 4 Gas Wall-Mount Monitor when a space has several gas hazards and you want one fixed head.
- For combustibles only, the EX LEL Detector costs less.
- For battery-room hydrogen, use the Hydrogen Detector.
Frequently asked questions
What gases does the Forensics 4 gas wall-mount monitor detect?
CO, H2S, O2 and combustible LEL — the four atmospheric hazards — continuously, from one fixed head. It does not detect VOCs or specific toxics like chlorine.
Why choose a fixed 4-gas monitor over single-gas heads?
One unit covers all four hazards, simplifying installation and wiring where several gases are a risk. For a single hazard, a dedicated head like the EX LEL Detector costs less.
What is the relay output used for?
It triggers external action — ventilation, remote alarms or equipment shutdown — when any monitored gas reaches its set point.
Where should it be mounted?
Position it considering each gas's density and the room's release points and occupied zones; below-grade and enclosed plant rooms are common applications.
Is it NIST calibrated?
Yes — USA NIST-traceable calibration; plan periodic recalibration of each sensor with the appropriate calibration gas.
Can it replace portable detectors for entry?
No — pre-entry testing still needs a Portable Gas Detectors instrument. The fixed monitor provides continuous coverage of the installed space.
Does it monitor oxygen deficiency?
Yes — oxygen is one of its four channels, alarming on deficiency (and typically enrichment) alongside CO, H2S and combustibles.
How is it powered and installed?
It is a hard-wired fixed monitor; installation and relay wiring should follow local electrical code and any area-classification requirements.
What does it not detect?
VOCs, CO2 and specific toxics such as chlorine or ammonia. For a single combustible point use the EX LEL Detector; for hydrogen the Hydrogen Detector.
Is it in stock and how does it ship?
Use the Amazon buy button for current availability and delivery timing through our fulfillment partner.
Can it drive building ventilation automatically?
Yes — that is a core use of the relay output: energise exhaust or a shutdown circuit when gas reaches the alarm level.
How many heads does a facility need?
One per area near its release points; larger or multi-room facilities add heads positioned by airflow and gas density, often wired to a central controller.
Ready to order the Forensics 4 gas wall-mount monitor? Add it to your cart above, or check the current Amazon price below. Compare it against the rest of our Fixed Gas Detection Systems lineup before you buy.
CHECK PRICE ON AMAZON →As an Amazon Associate, WC Safety earns from qualifying purchases.
Last updated: · Sources reviewed: manufacturer product listing & specifications, OSHA 29 CFR 1910.146, OSHA Annotated PEL tables, ACGIH Threshold Limit Values.
Editorial standard: Zero sponsored listings. No manufacturer input. Specs verified against the manufacturer’s published data.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.