Skip to content
Industrial Safety Equipment, PPE Guides & Reviews
Industrial Safety Equipment, PPE Guides & Reviews

Reference

RSS
  • August 16, 2026 Steven Eaton

    Hearing Protector Fit Testing & PAR: OSHA/NIOSH 2026 Guide

    Hearing protector fit testing measures what one worker actually gets from one earplug, reported as a personal attenuation rating in decibels. OSHA's February 2026 bulletin calls it a best practice but says a PAR cannot replace the NRR for selection. Covers NRR versus PAR, the 2025 NIOSH change, target PAR, and a worked example.
    Read now
  • August 15, 2026 Steven Eaton

    Catalytic Bead vs Infrared LEL Sensors: How to Choose

    A catalytic bead burns the gas and measures the heat released; an infrared sensor measures the light the gas absorbs. Catalytic needs oxygen and can be poisoned but detects hydrogen. Infrared cannot be poisoned but is blind to hydrogen. This guide covers both principles and the specification decision that follows from them.
    Read now
  • August 15, 2026 Steven Eaton

    Gas Sensor Poisoning: What Kills an LEL Sensor and How to Catch It

    A poisoned catalytic bead sensor does not fault, blank or warn you. It reads low, silently, in a flammable atmosphere. This guide covers the compound classes that cause it, the difference between poisoning and inhibition, why calibration cannot fix it, and the daily function check that turns a silent failure into a visible one.
    Read now
  • August 15, 2026 Steven Eaton

    Gas Detector Cross-Sensitivity: Why Sensors Read the Wrong Gas

    Cross-sensitivity is a sensor responding to a gas it was not built to measure, and it is not a defect but a property of the sensing chemistry itself. This guide covers the mechanism, the interference patterns crews actually meet, the under-reporting direction nobody expects, and how to diagnose a suspect alarm from clean air.
    Read now
  • August 15, 2026 Steven Eaton

    ppm vs %LEL vs %Volume: Gas Detector Units Explained

    ppm and %volume tell you how much gas is actually present. %LEL tells you how close the atmosphere is to igniting. Confusing the two understates a methane hazard twentyfold. This guide covers the conversion arithmetic, why each channel uses the unit it does, and how to cross-check a mixed-unit display for consistency before entry.
    Read now
  • August 15, 2026 Steven Eaton

    How to Read a 4-Gas Monitor: O2, LEL, CO and H2S Readings Explained

    A 4-gas monitor shows four channels in three different units, and they are not comparable to each other. This guide reads the display field by field: the clean-air baseline, what an oxygen drop implies, why 10% LEL is not 10% gas, what the LOW, HIGH, TWA, STEL and PEAK labels mean, and which hazards the four channels cannot see at all.
    Read now
  • July 24, 2026 Steven Eaton

    Cbrn Filter Ratings Explained

    CBRN stands for chemical, biological, radiological, and nuclear β€” but a β€œCBRN-rated” filter can mean very different things depending on who certified it. This reference decodes NIOSH CBRN approvals and European ABEK ratings, explains expiry and storage rules, and covers the hazards no filter can stop.
    Read now
  • July 11, 2026 Steven Eaton

    N95 Vs Ffp2 Vs Ffp3

    N95 is a NIOSH (US) filtering facepiece rating; FFP2 and FFP3 come from Europe's EN 149. The filtration numbers look close β€” 95%, 94%, 99% β€” but the test methods, leakage requirements, and legal acceptance differ. Here is the honest conversion logic, the markings that prove authenticity, and what each jurisdiction accepts.
    Read now
  • June 22, 2026 Steven Eaton

    What Is A PAPR Powered Air Purifying Respirator

    A PAPR uses a blower to push filtered air into a hood or mask, giving higher protection and far more comfort than a tight-fitting respirator, often without a fit test. This guide explains how a powered air-purifying respirator works, its assigned protection factor, how it compares to half- and full-face respirators, and who actually needs one.
    Read now
  • June 22, 2026 Steven Eaton

    Respirator Cartridge Shelf Life

    Respirator cartridges have two separate clocks: a sealed shelf life and an in-use service life, and confusing them leaves workers breathing through a spent filter. This guide covers how to read the printed expiration date, how to store sealed and opened cartridges, and why gas and vapor cartridges differ from P100 particulate filters.
    Read now
  • June 22, 2026 Steven Eaton

    Dual Hearing Protection

    Wearing earplugs and earmuffs together is the right call above about 100 dBA, but the protection does not add up. This guide explains dual hearing protection: when OSHA and NIOSH call for it, why combined NRR is not the sum of the two devices, how to apply the +5 dB rule, and how to combine plugs and muffs correctly.
    Read now
  • May 14, 2026 Steven Eaton

    Respirator Cartridge Color Codes

    Respirator cartridge colors follow ANSI K13.1 (required by 42 CFR 84.193): black = organic vapor, white = acid gas, magenta = P100 HEPA. This guide decodes all ten color classes, combination cartridge color bands, brand-by-brand model number mapping for 3M, Honeywell North, and Moldex, and what the colors do not tell you about a.
    Read now