Gateway Safety PeakFit 80101 N95 Respirator, Unvented
WC Safety Editorial Pick β Gateway Safety PeakFit 80101 β N95 cup with PeakFit geometry for diverse nose bridge profiles. Read our full review β Β |Β Browse all Gateway Safety disposable respirators β Gateway Safety P...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Gateway Safety PeakFit 80101 N95 Respirator (Unvented) β NIOSH-Approved N95 Disposable Respirator
Gateway Safety PeakFit 80101 N95 Respirator (Unvented) is Gateway Safety's PeakFit N95 β the PeakFit cup geometry is engineered to accommodate a broader range of nose bridge profiles than a standard N95 cup, reducing the gap leakage risk that can occur when a standard cup sits flat against an atypical nose bridge.
Jump to: Key Features Β· Specs Β· Hazard Coverage Β· Compare Β· FAQ
The Gateway Safety PeakFit 80101 N95 Respirator (Unvented) is a NIOSH-approved N95 filtering facepiece respirator from Gateway Safety, listed on the NIOSH Certified Equipment List. Read the complete disposable respirator guide to compare NIOSH filter classes before ordering.
Key Features β 80101 PeakFit
- NIOSH N95 approval for non-oil particulates at minimum 95% filtration efficiency
- PeakFit cup geometry designed to accommodate diverse nose bridge profiles
- No exhalation valve β appropriate where source control is also required
- Dual elastic headbands and adjustable nose clip for a secure seal
- 10-count box for industrial team purchasing
- PeakFit geometry for diverse nose bridge shapes
- NIOSH N95 verified
- No valve β source control compatible
- Gateway Safety reliability
- No valve β warmer than valved 80302V
- No nuisance-relief layer
- 10-pack β order multiples for large crews
Specifications
| Specification | Detail |
|---|---|
| Brand | Gateway Safety |
| Model | 80101 PeakFit |
| NIOSH Class | N95 |
| Exhalation Valve | No |
| Nuisance Relief | None |
| Shell Shape | Cup (PeakFit) |
| Headstraps | Dual elastic |
| Pack Size | 10/Box |
Typical Applications
- Teams with diverse nose bridge profiles; see all N95 respirators
- General construction and industrial particulate environments
- Environments requiring source control with N95 filtration; see all disposable respirators
- Fit-test all wearers; see our fit testing guide
Hazard Coverage β Gateway Safety PeakFit 80101 N95 Respirator (Unvented)
The Gateway Safety PeakFit 80101 N95 Respirator (Unvented) is NIOSH-approved under 42Β CFRΒ 84 SubpartΒ K for non-oil-based particulates at β₯95% efficiency. Approved hazards include construction and masonry dust, pollen, mold spores, smoke particulates, grain and wood dust, and certain biological aerosols. The 80101 PeakFit is NOT rated for oil-based particles β spray paint mist, cutting fluid aerosols, and lubricant mist degrade N-class electret media faster than rated. For oil environments choose an R95 (oil-resistant, one shift) or P100 (oil-proof). Compare classes in our N95 vs P100 guide and the complete disposable respirator guide.
Compare 80101 PeakFit vs 80302V TruAir vs 80301 TruAir
| Model | Filter | Valve | Pack | Best For |
|---|---|---|---|---|
| 80101 PeakFit (this page) | N95 | No | This product | |
| 80302V TruAir | N95 | Yes | 10/Box | TruAir with valve |
| 80301 TruAir | N95 | No | 10/Box | TruAir unvalved |
Frequently Asked Questions
Is the 80101 PeakFit NIOSH-approved?
Yes. The 80101 PeakFit is NIOSH-approved under 42Β CFRΒ 84 SubpartΒ K as an N95 filtering facepiece respirator, confirming it filters at least 95% of airborne particles β₯0.3Β microns. Verify the TC approval number on the NIOSH Certified Equipment List.
What does the N95 rating mean for the 80101 PeakFit?
The N in N95 stands for not resistant to oil β the 80101 PeakFit is approved for non-oil-based particulates such as dust, pollen, mold spores, and smoke. It should not be used in environments with oil-based aerosols (spray paint mist, cutting fluid, lubricant mist). For oil environments, choose an R95 or P100 mask instead.
Can I reuse the 80101 PeakFit?
Disposable N95 respirators like the 80101 PeakFit are designed for single extended use or limited reuse per OSHA guidance β they are not washable. Discard when the mask becomes soiled, damaged, hard to breathe through, or after use in a hazardous environment. Follow your employer's written respiratory protection program for reuse decisions.
Does the 80101 PeakFit require a fit test?
Yes. OSHA 29Β CFRΒ 1910.134 requires a fit test before first use of any N95 respirator in a workplace where it provides occupational protection. Read our fit test guide for qualitative and quantitative options. The 80101 PeakFit should seal flush against your skin without gaps at the nose bridge or chin.
How do I know the 80101 PeakFit fits correctly?
Perform a user-seal check each time you don the mask: cup both hands over the mask and exhale sharply β if you feel air escaping at the edges, re-adjust the nose clip and re-seat the straps. Our respirator sizing guide covers fit factors by face shape. A proper seal is essential for rated N95 protection.
Is the 80101 PeakFit safe for COVID-19, smoke, or wildfire ash?
An N95 like the 80101 PeakFit filters particles at the same size range as many respiratory aerosols, smoke particulates, and wildfire ash. However, this product is an industrial respirator β it is not FDA-cleared as a surgical mask unless specifically noted. Check the product label for FDA clearance status if healthcare use is required.
How many 80101 PeakFit respirators come in a box?
Pack size is shown in the product title and on the box. Browse the full disposable respirator catalog for available box counts β options range from individual pouches to bulk industrial packs.
Can I use the 80101 PeakFit for spray painting?
No. Spray paint and primer produce oil-based aerosols that break down N95 electret filter media faster than rated. For paint booth and spray work, choose an R95 (oil-resistant) or pair an R95 or P100 with an OV/AG nuisance cartridge layer. See our full respirator guide for the right class.
What is the shelf life of the 80101 PeakFit?
Most disposable N95 respirators carry a manufacturer shelf life of 5Β years from the production date when stored in the original sealed packaging away from sunlight, heat, and humidity. Check the lot code and expiration date printed on the box before use.
Do I need a medical evaluation before using the 80101 PeakFit at work?
OSHA 29Β CFRΒ 1910.134 requires a medical evaluation before an employee is required to wear a tight-fitting respirator at work. Employers must provide the OSHA Medical Evaluation Questionnaire (AppendixΒ C) before fit testing. Voluntary use of filtering facepieces in non-hazardous environments has a simpler pathway β consult your safety officer.
What hazards does the 80101 PeakFit NOT protect against?
The 80101 PeakFit does not protect against gases, vapors, or chemical vapors β including carbon monoxide, solvent vapors, or ammonia. It also provides no protection against oxygen-deficient atmospheres. For those hazards, use a supplied-air respirator or a half-face/full-face respirator with the appropriate cartridge. See our disposable respirator guide for scope-of-use guidance.
How should I store unused 80101 PeakFit respirators?
Store unopened 80101 PeakFit respirators in the original sealed bag or box, in a cool, dry location away from direct sunlight, chemicals, and extreme temperature. Do not crush or fold the masks. Opened but unused masks can be placed in a clean paper bag in a dust-free area between uses β never in a pocket or toolbox where they can become contaminated or deformed.
Ready to order the Gateway Safety respirator? Buy from WC Safety or on Amazon.
Add to Cart β WC SafetyAmazon purchases via WC Safety links earn us an affiliate commission at no extra cost.Last updated: Β· Sources reviewed: NIOSH 42 CFR 84 Subpart K, OSHA 29 CFR 1910.134, NIOSH NPPTL Certified Equipment List, Gateway Safety Technical Data Sheet, ANSI/ASSE Z88.2-2015.
Editorial standard: Zero sponsored listings. No manufacturer input. Specs independently verified against the NIOSH approval certificate.
Primary sources: NIOSH 42 CFR 84 approval database, OSHA 29 CFR 1910.134, Gateway Safety Technical Data Sheet, NIOSH NPPTL Certified Equipment List. Reviewed when NIOSH updates approval criteria or Gateway Safety updates the 80101 PeakFit lineup. Last review: 2026-06-19.
WC Safety participates in the Amazon Associates Program (tag: wcsafety04-20). Product links to Amazon earn us a commission on qualifying purchases at no extra cost. This page does not constitute medical, legal, or regulatory advice. Consult a Certified Industrial Hygienist (CIH) for site-specific respiratory protection requirements.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.