Skip to content
Industrial Safety Equipment & PPE — ANSI/OSHA Compliant
Industrial Safety Equipment & PPE — ANSI/OSHA Compliant
Home Allegro 9935-BLW EZ Air PAPR Blower Assembly

Allegro 9935-BLW EZ Air PAPR Blower Assembly

Allegro Industries SKU: 9935-BLW Powered Air Purifying Respirator GTIN: 0741851993539
$900.00
Final price set by Amazon · may vary

Disclosures & editorial standardsWC Safety participates in the Amazon Services LLC Associates Program. Outbound Amazon links are affiliate links. We accept no manufacturer payment, sponsorship, or product sam...

Check Price on Amazon

🔒 Amazon Associate · You pay the same price · We earn a small commission

Zero Sponsored ListingsNo paid placements. Every recommendation is based on compliance, build quality, and field performance.
Curated SelectionExpert-chosen safety gear
Independently ReviewedUnbiased assessments — no manufacturer input
Built for Industrial BuyersSourced and reviewed for safety managers, procurement teams, and field supervisors.
9935-BLW Allegro Blower Assembly EZ Air PAPR
Disclosures & editorial standards
WC Safety participates in the Amazon Services LLC Associates Program. Outbound Amazon links are affiliate links. We accept no manufacturer payment, sponsorship, or product samples. This content is not medical, legal, or regulatory advice. Safety equipment selection is governed by applicable OSHA standards and your facility's safety program.

Allegro 9935-BLW EZ Air PAPR Blower Assembly — Replacement Motorized Blower Unit

The Allegro 9935-BLW is the motorized blower assembly for the Allegro EZ Air powered air-purifying respirator (PAPR) system. It delivers a continuous flow of NIOSH-filtered positive-pressure air to the supplied hood or helmet, eliminating the need for fit testing and negative-pressure breathing effort. The 9935-BLW is the core blower unit of the EZ Air system — it attaches to compatible Allegro PAPR hoods and filter cartridges to form a complete respiratory protection assembly. As a replacement blower component, it is ordered separately from the hood, hose, and filter. UPC: 741851993539. Shop the full powered air purifying respirators collection.

Vendor: Allegro Industries | SKU: 9935-BLW | UPC: 741851993539 | View on Amazon

9935-BLW Blower Assembly Specifications

Specification Detail
Component Type Replacement PAPR blower assembly
System Allegro EZ Air PAPR
Approval NIOSH-approved (used with compatible NIOSH-approved filters)
Pressure Type Positive pressure delivery
Fit Test Required No (positive pressure PAPR)
Facial Hair Compatible Yes (hood-based system)
UPC 741851993539

Half-Mask APR vs. Allegro EZ Air PAPR: Key Differences

Factor Half-Mask APR Allegro EZ Air PAPR
Fit Testing Required Yes (annual) No
Facial Hair Not permitted at seal Permitted
Breathing Resistance Negative pressure (user draws air through filter) Positive pressure (blower delivers air)
Assigned Protection Factor 10 25 (LF hood) or 1000 (TH3)
Comfort for Extended Wear Moderate (face pressure, breathing effort) High (no face contact, cool airflow)

Frequently Asked Questions — Allegro 9935-BLW

What is the 9935-BLW — is it a complete PAPR system?
The 9935-BLW is the blower motor assembly only — it is not a complete PAPR system. The full Allegro EZ Air PAPR system requires the blower unit (9935-BLW), a compatible PAPR hood or helmet, a supply hose, and NIOSH-approved filter cartridges. The 9935-BLW is sold as a replacement blower for existing EZ Air systems or as the blower component when building a PAPR assembly from individual parts.
Does the Allegro EZ Air PAPR require fit testing?
No. Positive-pressure PAPRs do not require respirator fit testing under OSHA 29 CFR 1910.134. Because the blower maintains positive pressure inside the hood, air leaks outward rather than inward — contaminated air cannot enter through minor gaps the way it can with negative-pressure tight-fitting respirators. This makes the EZ Air system appropriate for workers who cannot achieve a reliable half-mask seal due to facial hair, facial features, or medical conditions.
What is the APF for the Allegro EZ Air PAPR?
The Assigned Protection Factor (APF) for the Allegro EZ Air PAPR depends on the hood or helmet used. Loose-fitting hood PAPRs (LF classification) have an APF of 25. TH3-classified tight-fitting or helmeted units have an APF of 1000. OSHA Table 1 in 29 CFR 1910.134 Appendix A defines APFs for each respirator class. For most industrial particulate applications, the LF PAPR (APF 25) provides substantially more protection than a half-mask APR (APF 10) without requiring fit testing.
What filters are compatible with the 9935-BLW blower?
The 9935-BLW blower is designed to work with Allegro EZ Air PAPR filter cartridges — both particulate and combination organic vapor/P100 filters are available in the EZ Air filter line. Always use NIOSH-approved filters with any PAPR assembly. Using non-approved or incompatible filters voids the NIOSH approval of the assembly and the OSHA compliance status of the respiratory protection program.
Can the Allegro EZ Air PAPR be used for welding?
The Allegro EZ Air PAPR system can be used for welding fume protection when equipped with the appropriate NIOSH-approved particulate filter (P100 or HEPA). For welding operations with a PAPR, you also need a compatible welding helmet or shield that integrates with the PAPR hood to provide both arc flash and UV protection. Allegro offers PAPR-compatible welding accessories. For a fully integrated welding PAPR helmet, see the PAPR welding systems in the collection.
What OSHA standards govern PAPR use?
PAPR use is governed by OSHA 29 CFR 1910.134 (Respiratory Protection) in general industry. Key requirements include: a written respiratory protection program, a medical evaluation before use, training, and proper maintenance and storage procedures. PAPRs are exempt from fit testing (29 CFR 1910.134(f)(1)(ii)(C)) but are not exempt from the medical evaluation or program requirements. Employers must also ensure the PAPR selected provides an APF adequate for the contaminant concentration present.
How long does the blower battery last on the 9935-BLW?
Run time depends on airflow speed and battery charge. Allegro EZ Air systems typically provide several hours of continuous operation at standard airflow rates. For shift-length wear, users should confirm battery run time at their operating speed and keep spare batteries or a charging solution available. The battery is part of the complete EZ Air system — refer to Allegro Industries product documentation for specific run-time data for the 9935-BLW configuration.
Is the 9935-BLW the same as the Allegro 9935 complete kit?
No. The 9935-BLW is the blower assembly component only. The Allegro 9935 series complete PAPR kits include the blower, hood, hose, and filter(s) as a packaged system. The "-BLW" suffix designates the blower-only variant. If you need a replacement blower for an existing EZ Air system, the 9935-BLW is the correct SKU. If you are building a new PAPR program from scratch, the complete kit may provide better value and ensure component compatibility.
Related Respiratory Protection
All PAPRs  |  Half-Mask Respirators  |  Cartridges & Filters  |  Disposable Respirators
Brand / Vendor
Allegro Industries
Model / SKU
9935-BLW
Product Type
Powered Air Purifying Respirator
Price
$900.00 (Amazon)
Availability
Check current availability on Amazon
🏷️
No Paid Placements
Every product earns its place based on safety credentials and field performance, not advertising spend.
🏭
Industrial Grade Only
Products sourced for professional use in manufacturing, construction, and industrial environments.
🔬
Compliance Verified
Every product listed on WC Safety is reviewed for standards compliance and safety credentials before publication.
🏭
Sourced for Professionals
Gear selected for safety managers, procurement teams, and field supervisors — not casual consumers.
Verified Buyer Reviews

Customer Reviews

Share Your Experience

Write a Review

Select a rating

Thank you for your review!

Your submission has been received and will be published after verification.

Allegro 9935-BLW EZ Air PAPR Blower Assembly