3M 60926 Multi-Gas P100 Cartridge — Organic Vapor, Acid Gas, Ammonia, Formaldehyde & More for 3M 6000/7000/FF-400
The 3M 60926 Multi-Gas P100 Cartridge is 3M's broadest combination cartridge — NIOSH-approved against ten chemical categories, from organic vapor and acid gas to ammonia, formaldehyde, and hydrogen fluoride, pai...
Check Price on Amazon🔒 Amazon Associate · You pay the same price · We earn a small commission
The 3M 60926 Multi-Gas P100 Cartridge is 3M's broadest combination cartridge — NIOSH-approved against ten chemical categories, from organic vapor and acid gas to ammonia, formaldehyde, and hydrogen fluoride, paired with a P100 particulate filter. It sits at the top of our multi-gas cartridge range as the one-cartridge answer for mixed or uncertain chemical hazards.
Read the full 3M 60926 Multi-Gas P100 Cartridge review →
Its breadth is the whole point — and also the thing to think about. "Multi-gas" covers a wide list but not every gas, and for a single known hazard a narrower cartridge is often the smarter buy. Below we spell out exactly what it covers, what it does not, and when to reach for something else.
As an Amazon Associate, WC Safety earns from qualifying purchases. This does not affect the price you pay.
What the 3M 60926 Multi-Gas P100 Cartridge Protects Against
The 60926 pairs a broad multi-gas sorbent with a P100 particulate filter (99.97% of oil and non-oil aerosols, magenta band). Its NIOSH approval spans ten chemical categories: certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide, ammonia, methylamine, formaldehyde, and hydrogen fluoride. That combined coverage is why it is the go-to cartridge for environments where several gases — or an uncertain mix within its rating — appear alongside dust or mist. On a 3M bayonet facepiece it can be used up to 10 times the PEL on a half mask and 50 times on a quantitatively fit-tested full facepiece.
The trade-off with any broad cartridge is efficiency: a narrower cartridge is lighter, cheaper, and breathes easier, and it often lasts longer against a single contaminant. So reach for the 60926 when your hazard is genuinely mixed or unknown-within-rating, and drop to a matched cartridge when it is not — the 60921 for organic vapor, the 60922 for acid gas, the 60923 for organic vapor plus acid gas, the 60924 for ammonia, or the 60925 for formaldehyde. Our multi-gas cartridge guide maps the choice.
Safety note: This is an air-purifying cartridge — it does not supply oxygen. Never use it in an oxygen-deficient or IDLH atmosphere, against carbon monoxide (which no cartridge filters), or above its concentration limits; those require a supplied-air respirator or an SCBA. "Multi-gas" covers a broad list, not every gas — match it to a measured contaminant, and because some covered gases such as formaldehyde and hydrogen sulfide have poor warning properties, follow a written change schedule and gas monitoring rather than relying on odor.
Where It Fits in the 3M 60900 Line
The 60900 series is a ladder of combination cartridges on the same P100 platform, and the 60926 sits at the top for breadth. Below it, each cartridge trades coverage for economy: organic-vapor-only, acid-gas-only, organic-vapor-plus-acid-gas, ammonia, and formaldehyde. Above and beside it, the 60928 adds mercury vapor and chlorine with an end-of-service-life indicator. All of them fit the same 3M 6000, 7000, and FF-400 facepieces, so you can match the cartridge to the hazard without changing masks. If you only need particulate, a filter like the 3M 2091 P100 is the lighter option, and for a broader look at respirator selection start with when do you need a respirator.
Pros & Cons
Strengths
- Broadest 3M combination — 10 chemical categories
- Organic vapor, acid gas, ammonia, formaldehyde, HF in one
- P100 particulate (99.97%) for dust, fume, and mist
- Up to 10x PEL (half) / 50x PEL (full facepiece)
- Fits any 3M 6000/7000/FF-400 bayonet respirator
Limitations
- Does not filter carbon monoxide — needs supplied air
- Broader and pricier than a matched single-gas cartridge
- No ESLI — poor-warning gases need a change schedule
- 3M bayonet only — not cross-brand
- Not for isocyanate 2K spraying (supplied-air preferred)
Specifications
| Brand / Model | 3M 60926 |
| UPC | 50051138541878 |
| NIOSH rating | Multi-gas/vapor (10 categories) / P100 |
| Gases covered | OV, Cl, HCl, SO2, ClO2, H2S, NH3, methylamine, formaldehyde, HF |
| Particulate | P100 (99.97% oil and non-oil) |
| Color code | Magenta (P100) / olive |
| Connection | 3M bayonet — 6000/7000/FF-400 |
| Not for | Carbon monoxide, oxygen-deficient/IDLH, isocyanate spraying |
Related Guides
Related Products
- 3M 60923 OV / Acid Gas / P100 — narrower, longer-lasting
- 3M 60924 Ammonia / Methylamine / P100
- 3M 60925 Formaldehyde / OV / P100
- 3M 60928 Multi-Gas + Mercury / P100
- 3M 2091 P100 Filter — particulate only
- All Combination Cartridges
Frequently Asked Questions
Exactly which gases and vapors does the 60926 protect against?
NIOSH approves the 60926 against ten chemical categories: certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide, ammonia, methylamine, formaldehyde, and hydrogen fluoride — plus non-oil and oil particulate at P100 (99.97%). It is the broadest single cartridge in the 3M 60900 line, combining organic vapor, acid gas, ammonia, and formaldehyde coverage in one housing.
Does the 60926 protect against carbon monoxide?
No. No air-purifying cartridge, however broad, filters carbon monoxide — CO passes straight through sorbent media. Carbon monoxide requires a supplied-air respirator or a CO-specific system with monitoring. Never assume a "multi-gas" cartridge covers CO.
How do I choose between the 60926 and a narrower single-gas cartridge?
Match the cartridge to your actual hazard. If you face several gases at once, or an uncertain mix within its rating, the 60926's breadth is the point. But for a single known hazard, a narrower cartridge is lighter, cheaper, breathes easier, and often lasts longer — the 60921 for organic vapor, the 60922 for acid gas, the 60923 for organic vapor plus acid gas, the 60924 for ammonia, or the 60925 for formaldehyde. Buy breadth only when you need it.
What is the difference between the 60926 and the 60928?
Both are broad multi-gas P100 cartridges, but the 60928 adds mercury vapor and chlorine with an end-of-service-life indicator (ESLI) for those, which the 60926 does not have. If mercury vapor is part of your hazard, look at the 60928; for the wide gas mix without mercury, the 60926 is the standard choice.
Does the 60926 protect against hydrogen sulfide?
Hydrogen sulfide is in the 60926's NIOSH-approved list, but H2S is acutely toxic and deadens your sense of smell, so treat it with extra caution: rely on gas monitoring and a strict change schedule, not odor, and confirm the specific H2S provisions and any escape limitations on the approval label before entry. For high H2S or oxygen-uncertain work, consider a supplied-air respirator.
Does formaldehyde or another poor-warning gas change how I use it?
Yes. Several covered gases — formaldehyde among them — have poor warning properties, meaning you can be overexposed before you smell anything, and the cartridge has no end-of-service-life indicator for them. Use a written change schedule based on your exposure rather than waiting for odor or taste, especially where formaldehyde or hydrogen sulfide is present.
Is the 60926 compatible with non-3M masks like Honeywell, MSA, or GVS?
No. The 60926 uses the 3M bayonet connection and fits only 3M 6000, 7000, and FF-400 series facepieces. It is not interchangeable with Honeywell/North, MSA, Moldex, or GVS Elipse masks — mixing brands voids the NIOSH approval and can compromise the seal.
What is the assigned protection factor of the 60926?
Fitted correctly, it can be used up to 10 times the PEL on a half facepiece and up to 50 times on a quantitatively fit-tested full facepiece, for the gases and particulate in its rating. If your measured exposure exceeds those multiples, you need a powered or supplied-air respirator, not this cartridge.
Do I need a fit test with the 60926?
Yes. Any tight-fitting respirator used at work requires an OSHA fit test and a user seal check each time you don it, and it will not seal over facial hair on the sealing surface. A cartridge only performs behind a properly sealed facepiece — a leak lets contaminated air bypass it entirely.
Can I use the 60926 for spraying 2K (isocyanate) automotive paint?
Be cautious. While the 60926's organic-vapor stage covers many solvents, NIOSH and coatings-industry guidance favor a supplied-air respirator for spraying two-component (2K) isocyanate finishes, because isocyanate aerosol has poor warning properties and spray concentrations can exceed an air-purifying respirator's protection factor. Use an air-purifying cartridge for isocyanates only where an exposure assessment and your written program confirm it is adequate.
What particulate does the P100 side capture?
The P100 filter captures at least 99.97% of oil and non-oil airborne particles — dusts, fumes, and mists, including hazards like silica, lead, and welding fume on the particulate side. That is why the 60926 works where gas and particulate hazards occur together; the sorbent handles the gases and the P100 handles the dust.
How should I store the 60926 between uses?
Store it sealed in an airtight bag, away from the contaminants it filters, and out of heat and direct sun. Leaving a cartridge open lets it passively load with vapor and shortens its service life. Note the date you first open it and factor that into your change schedule.
Reviewed by Steven Eaton, WC Safety. Specifications reflect 3M's published listing for cartridge/filter 60926 (UPC 50051138541878), NIOSH-approved against ten chemical categories plus P100 particulate. This is an air-purifying cartridge for breathable, below-limit atmospheres; it does not filter carbon monoxide and is not supplied-air protection. Match it to a measured contaminant, run a written change schedule for poor-warning gases, and confirm the approval label before entering any hazardous atmosphere.
Customer Reviews
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.