Skip to content
Industrial Safety Equipment & PPE β€” ANSI/OSHA Compliant
Industrial Safety Equipment & PPE β€” ANSI/OSHA Compliant
Home β€Ί 3M Respirator Filters and Cartridges β€” Bayonet & Secure Click β€Ί 3M Secure Click D9093CB P100 Filter, Hard Case ...

3M Secure Click D9093CB P100 Filter, Hard Case with Nuisance Acid Gas Relief (Case/144)

3M SKU: D9093CB Respirator Filter GTIN: 0689330191567
$1,136.79
Final price set by Amazon Β· may vary

EDITORIAL REVIEW: 4.5/5 WC Safety Review β€” the 3M Secure Click D9093CB P100 filter Read the full 3M Secure Click D9093CB P100 Filter, Hard Case with Nuisance Acid Gas Relief (Case/144) review β†’ Editorial assessmen...

Check Price on Amazon

πŸ”’ Amazon Associate Β· You pay the same price Β· We earn a small commission

Zero Sponsored ListingsNo paid placements. Every recommendation is based on compliance, build quality, and field performance.
Curated SelectionExpert-chosen safety gear
Independently ReviewedUnbiased assessments β€” no manufacturer input
Built for Industrial BuyersSourced and reviewed for safety managers, procurement teams, and field supervisors.
3M abatement Acid Gas asbestos case quantity Combination Cartridge crew supply FF-800
EDITORIAL REVIEW: 4.5/5 WC Safety Review β€” the 3M Secure Click D9093CB P100 filter

Read the full 3M Secure Click D9093CB P100 Filter, Hard Case with Nuisance Acid Gas Relief (Case/144) review β†’

Editorial assessment by Steven Eaton, WC Safety editor, based on published 3M specifications and category fit. We did not laboratory-test this product.

CHECK PRICE ON AMAZON β†’SHOP 3M FILTERS β†’

As an Amazon Associate, WC Safety earns from qualifying purchases. Full affiliate disclosure.

3M Secure Click D9093CB P100 Filter, Hard Case with Nuisance Acid Gas Relief Overview

The 3M Secure Click D9093CB P100 filter is a hard-case P100 particulate filter with nuisance-level acid gas relief, for the 3M Secure Click HF-800 half-facepiece and FF-800 full-facepiece respirators, sold by the case of 144. As a P100 filter it captures at least 99.97% of airborne particles and is oil-proof, covering dusts, mists, fumes, and welding fume.

As the 3M D9093CB, this Secure Click P100 filter is the D9093CB hard case filter built for rugged use. Its 3M P100 nuisance acid gas relief reduces acid-gas odor below the exposure limit, and as a Secure Click HF-800 filter it snaps on with the Secure Click latch, no retainer needed.

The nuisance-level relief is odor relief only, not acid-gas protection. For actual acid gas exposure, pair the facepiece with the Secure Click D8003 organic vapor and acid gas cartridge. Compare the non-hard-case D3096 P100 nuisance acid gas filter and the plain D3091 P100 particulate filter, and browse the range in 3M respirator filters and cartridges.

What This Filter Is For

Need Fit Buyer guidance
Dust, mist, fume, welding fume Purpose-built P100 captures at least 99.97% of particles; oil-proof.
Rugged environments Strong Hard case shields the media from damage.
High-use sites Strong Bulk case of 144 for stocking programs.
Acid gas at or above the limit Not suitable Odor relief only; use the D8003 gas cartridge.
Oxygen-poor or emergency air Not suitable Particulate filter; needs a supplied-air system.

A filter only works within a complete, matched, compliant system. The D9093CB is a P100 particulate filter: it captures particles but does nothing for gases or vapors. Its nuisance-level acid gas relief is odor relief for acid gas below the exposure limit and is never respiratory protection; where acid gas is at or above the exposure limit you must fit a rated gas cartridge such as the D8003. No particulate filter makes a respirator usable in an IDLH or oxygen-deficient atmosphere, which requires a supplied-air respirator or an SCBA. Fit test the HF-800 or FF-800 facepiece for each wearer, run a user seal check before every use, replace filters when breathing resistance rises or they are damaged, and use the system within a written program under OSHA 29 CFR 1910.134. Learn more in our 3M Secure Click filters and cartridges guide and the respiratory protection complete guide.

Pros & Cons

Pros
  • P100: at least 99.97% of particles, oil-proof
  • Hard case shields the media in rugged work
  • Nuisance acid-gas odor relief for comfort below the limit
  • Snaps on with the Secure Click latch, no retainer
  • Bulk case of 144 for high-use sites
Cons
  • Odor relief only; not acid-gas protection
  • Particulate only; no gas or vapor protection
  • Fits only Secure Click HF-800 / FF-800 facepieces
  • Case quantity is more than a single user needs

How It Compares

The D9093CB is the hard-case P100 with odor relief in the Secure Click line. Weigh it against its siblings:

Option Protection Form Best for
D9093CB (this page) P100 + AG odor relief Hard case, case of 144 Rugged, high-use particulate work
D3096 P100 + AG relief P100 + AG odor relief Standard pack Same relief, smaller quantity
D8003 OV/AG cartridge Organic vapor + acid gas Gas cartridge Actual acid-gas exposure

Choose the D9093CB for rugged, high-volume particulate work, the D3096 for the same relief in a smaller pack, or the D8003 cartridge for real acid-gas protection. See our Secure Click filters and cartridges guide, the P95 vs P100 filter guide, and the 3M filter and cartridge guide.

Specifications

Brand 3M (Secure Click)
Model D9093CB hard-case P100 filter with nuisance acid gas relief
Filter class P100 (at least 99.97%, oil-proof); NIOSH approved
Added feature Nuisance-level acid gas odor relief (below the exposure limit; not protection)
Compatibility 3M Secure Click HF-800 and FF-800 respirators; direct latch, no retainer
Pack Case of 144; hard case per filter

Related Guides

3M Secure Click filters and cartridges guide, P95 vs P100 filter, 3M filter and cartridge guide, are respirator cartridges universal, 3M respiratory protection guide.

Related Resources

3M respirator filters and cartridges half-mask respirators full-face mask respirators 3M Secure Click D3091 P100 filter

Frequently Asked Questions

Is the D9093CB the hard-case version of the filter?

Yes. The D9093CB is the hard-case P100 filter with nuisance-level acid gas relief. The rigid cover shields the media from damage in rugged work, which suits environments with sparks, debris, or knocks. It seats on the Secure Click HF-800 and FF-800 respirators.

How do I install it on the respirator?

Align the connection on the facepiece with the filter and push until you hear a click. The Secure Click latch holds it in place, so installation is quick and tool-free. Confirm both filters are fully seated and check the seal before you start work.

What does the P100 rating mean?

P100 means the filter captures at least 99.97% of airborne particles and is oil-proof, the highest particulate class in the 3M line. It covers dusts, mists, fumes, and welding fume, but it is a particulate filter and does not address gases or vapors.

Can I use it for grinding, sanding, and welding fume?

Yes. As a P100 particulate filter it is well suited to grinding, sanding, and welding-fume particulates. Match the respirator and filter to your exposure, and add a gas or vapor cartridge separately if your task also releases gases or vapors.

Does the odor relief replace a gas cartridge?

No. The nuisance-level relief only reduces acid-gas odor when acid gas is present below the exposure limit; it is a comfort feature, not protection. Where acid gas is at or above the exposure limit you must use a rated gas cartridge such as the Secure Click D8003.

Can I use it in an oxygen-poor or emergency atmosphere?

No. A particulate filter never makes a respirator usable in an oxygen-poor or immediately dangerous atmosphere. Those conditions require a supplied-air respirator or self-contained air-tank apparatus, and you must confirm the environment first.

Do I still need a fit test?

Yes. The filter does not change the need to fit test the Secure Click HF-800 or FF-800 facepiece for each wearer, along with a user seal check before every use. Fit testing and the seal check are what deliver the respirator's rated protection.

Which cartridge do I use if I actually face acid gas?

For real acid-gas exposure at or above the exposure limit, use a Secure Click gas cartridge such as the D8003 organic vapor and acid gas cartridge, matched to your specific exposure. The D9093CB odor relief does not substitute for that protection.

How many filters are in the case?

This listing is a full case of 144 filters, which suits high-use sites and stocking programs that go through particulate filters quickly. For a smaller quantity, choose a standard pack of the equivalent Secure Click P100 filter instead.

Is it NIOSH approved?

Yes. The D9093CB is NIOSH approved for use with the 3M Secure Click HF-800 and FF-800 series respirators. Use it only within its NIOSH approval and a written respiratory protection program with the correct facepiece and components.

Do I need a written respiratory program?

Yes. Reusable respirators and their filters are used within a written respiratory protection program under OSHA 29 CFR 1910.134, including training, medical evaluation, fit testing, and maintenance. Follow the 3M manual for use and replacement.

How should I store and replace the filters?

Store sealed filters in a clean, dry place away from contaminants, and replace a filter when breathing becomes harder, when it is damaged or wet, or per your program and the 3M schedule. Inspect each filter before fitting it and discard damaged ones.

Written by Steven Eaton, WC Safety Editorial. Specifications sourced from 3M published data. Browse the range in 3M respirator filters and cartridges.

WC Safety is an independent PPE review site and Amazon Associate; no paid placement. Use respirators and filters only within a compliant program and follow the 3M manual, NIOSH approval, and OSHA requirements.

Brand / Vendor
3M
Model / SKU
D9093CB
Product Type
Respirator Filter
Price
$1,136.79 (Amazon)
Availability
Check current availability on Amazon
🏷️
No Paid Placements
Every product earns its place based on safety credentials and field performance, not advertising spend.
🏭
Industrial Grade Only
Products sourced for professional use in manufacturing, construction, and industrial environments.
πŸ”¬
Compliance Verified
Every product listed on WC Safety is reviewed for standards compliance and safety credentials before publication.
🏭
Sourced for Professionals
Gear selected for safety managers, procurement teams, and field supervisors β€” not casual consumers.
Verified Buyer Reviews

Customer Reviews

Share Your Experience

Write a Review

Select a rating
βœ“

Thank you for your review!

Your submission has been received and will be published after verification.

3M Secure Click D9093CB P100 Filter, Hard Case with Nuisance Acid Gas Relief (Case/144)