  • August 15, 2026 Steven Eaton

    Catalytic Bead vs Infrared LEL Sensors: How to Choose

    A catalytic bead burns the gas and measures the heat released; an infrared sensor measures the light the gas absorbs. Catalytic needs oxygen and can be poisoned but detects hydrogen. Infrared cannot be poisoned but is blind to hydrogen. This guide covers both principles and the specification decision that follows from them.
    Read now
  • August 15, 2026 Steven Eaton

    ppm vs %LEL vs %Volume: Gas Detector Units Explained

    ppm and %volume tell you how much gas is actually present. %LEL tells you how close the atmosphere is to igniting. Confusing the two understates a methane hazard twentyfold. This guide covers the conversion arithmetic, why each channel uses the unit it does, and how to cross-check a mixed-unit display for consistency before entry.
    Read now
  • August 13, 2026 My Store Admin

    Bump Test vs Calibration for Gas Detectors (2026 Guide)

    A bump test proves gas reaches the sensors and the alarms fire; a calibration check verifies the numbers; a full calibration corrects them. This guide quotes OSHA's gas-monitor bulletin on all three, the ISEA before-each-day's-use rule, the failure ladder, NIST-traceable gas and expiration rules, and a worked daily crew routine.