Skip to content
Welcome To WC Safety. Your Home to Everything Safety
Welcome To WC Safety. Your Home to Everything Safety
Home GVS Half Mask Respirators GVS Elipse OVAG P100 NIOSH Half Mask Respirator...
NIOSH Certified – OV/AG/P100

GVS Elipse OVAG P100 NIOSH Half Mask Respirator – Organic Vapor, Acid Gas & Particulate

GVS SKU: SPR113J Half Mask Respirator
★ ★ ★ ★ ★ 4.8 (567 reviews on WC Safety)
$39.99
Final price set by Amazon · may vary
Size: S/M

NIOSH-Certified Organic Vapor, Acid Gas, and P100 Particulate Protection The GVS Elipse OVAG P100 NIOSH Half Mask Respirator provides tri-class respiratory protection against organic vapors, acid gases, and P100-rat...

Key Features
  • NIOSH OV/AG/P100 Certified
  • Lightweight silicone facepiece
  • Tri-fold flat storage
  • Two sizes: S/M and M/L
  • Bayonet cartridge replacement system
Check Price on Amazon

🔒 Amazon Associate · You pay the same price · We earn a small commission

Zero Sponsored ListingsNo paid placements. Every recommendation is based on compliance, build quality, and field performance.
Curated SelectionExpert-chosen safety gear
Independently ReviewedUnbiased assessments — no manufacturer input
Built for Industrial BuyersSourced and reviewed for safety managers, procurement teams, and field supervisors.
acid-gas elipse gvs half-mask-respirator niosh-approved organic-vapor ov-ag-p100 p100

NIOSH-Certified Organic Vapor, Acid Gas, and P100 Particulate Protection

The GVS Elipse OVAG P100 NIOSH Half Mask Respirator provides tri-class respiratory protection against organic vapors, acid gases, and P100-rated particulates in a compact silicone half mask platform. NIOSH-certified under 42 CFR Part 84, this respirator suits workers in paint spraying, solvent handling, chemical processing, and industrial environments where simultaneous vapor and particulate hazards require a single integrated solution. The SPR113J (S/M) and SPR123J (M/L) models ship with GVS's low-profile bayonet cartridges and a soft silicone face seal designed for extended wear.

GVS engineered the Elipse series around the proposition that a half mask respirator can be light enough to be worn without fatiguing the user over a full shift. The silicone facepiece folds flat for pocket or tool-belt storage, and the three-point head strap reduces the mask's tendency to slide during overhead or dynamic work tasks. The result is a respirator that workers are more likely to keep on rather than remove during brief interruptions — a behavioral factor that directly affects real-world protection outcomes.

Compliance and Certification

The GVS Elipse OVAG P100 holds active NIOSH approval under 42 CFR Part 84. The OV/AG/P100 combination cartridge assembly provides organic vapor adsorption (activated carbon), acid gas adsorption, and P100 particulate filtration at 99.97% minimum efficiency against both oil and non-oil aerosols. Under 29 CFR 1910.134, any tight-fitting half mask used in a workplace respiratory protection program requires medical evaluation, fit testing, and training prior to use.

Performance Assessment

The Elipse delivers consistent face seal performance across its S/M and M/L size range, with the silicone material conforming more closely to facial contours than thermoplastic rubber alternatives at comparable price points. Breathing resistance is moderate at typical work rates; workers with high-exertion tasks may experience greater perceived resistance than at rest, which is characteristic of all combination OV/AG/P100 cartridges due to the combined filter bed depth.

The bayonet cartridge system allows tool-free replacement and is compatible across GVS's Elipse cartridge line. Cartridge service life is governed by organic vapor breakthrough — users should follow OSHA's change schedule requirements and the cartridge manufacturer's service life estimation method or an established change schedule in their written respiratory protection program.

Strengths

  • NIOSH OV/AG/P100 certification for multi-hazard protection in a single mask and cartridge assembly
  • Lightweight silicone facepiece with tri-fold storage design — flattens for compact carry without distortion
  • Soft silicone face seal reduces pressure points relative to harder-material competitors at similar price ranges
  • Available in two sizes (S/M, M/L) covering the majority of adult users
  • Compatible with standard GVS Elipse bayonet replacement cartridges for multiple protection levels

Limitations

  • Not rated for supplied-air or SCBA-required IDLH atmospheres — application is limited to environments below established IDLH levels
  • No integrated eye protection — separate safety eyewear required when eye splash or vapor hazard to eyes is present
  • Cartridge service life determination requires a written change schedule or objective monitoring — no end-of-service indicator is included

Recommended Use Cases

The GVS Elipse OVAG P100 is suited for automotive refinishing and spray painting, solvent-based product application, industrial chemical handling below IDLH concentration thresholds, laboratory environments with organic solvent exposure, and construction tasks involving both particulate and vapor hazards (e.g., epoxy application, urethane flooring). Select S/M (SPR113J) for smaller facial dimensions and most female users; M/L (SPR123J) for average to larger male users. OSHA-required fit testing must be performed to confirm adequate seal regardless of size selection.

Verdict and Alternatives

The GVS Elipse OVAG P100 is a solid choice for workers who need certified combination protection and value low weight and compact storage. Comparable alternatives include the 3M 6500 Series with 60923 combination cartridges for users in environments where wider cartridge sourcing is operationally important, or the MSA Advantage 200 LS for users who prefer a lower-profile nose-cup design with the same OV/AG/P100 protection class.

Frequently Asked Questions

What is the NIOSH certification number for the GVS Elipse OVAG P100?

The GVS Elipse OVAG P100 is certified under NIOSH 42 CFR Part 84. Current approval details, including the specific approval number and associated cartridge model, are verifiable on the NIOSH Certified Equipment List at cdc.gov/niosh/npptl. NIOSH certification requires independent laboratory testing and is not a manufacturer self-declaration.

What is the difference between SPR113J (S/M) and SPR123J (M/L)?

SPR113J and SPR123J are the same respirator in two facepiece sizes — S/M and M/L, respectively. Size selection should be based on GVS's published fit guide and confirmed via OSHA-required fit testing. S/M generally suits smaller facial geometries including most female users; M/L suits average to larger male users. Both sizes use the same OVAG P100 cartridges and provide identical NIOSH-certified protection.

How often must the cartridges be replaced?

Organic vapor cartridges do not include a visual end-of-service indicator. Replacement is required when organic vapor breakthrough odor is detected, at the end of a calculated service life per OSHA 29 CFR 1910.134 App B, or on a documented fixed change schedule. The P100 filter layer requires replacement when breathing resistance increases noticeably or the filter is physically damaged. In high-dust environments, more frequent replacement of the P100 element is standard.

Is the GVS Elipse appropriate for spray painting with isocyanate-based paints?

Isocyanate-based paints (polyurethane, two-component coatings) present both particulate and reactive isocyanate vapor hazards. OSHA and NIOSH guidance indicates that supplied-air respirators may be required at higher exposure concentrations for isocyanate applications. A Certified Industrial Hygienist (CIH) or Certified Safety Professional (CSP) should assess isocyanate exposure levels before selecting an air-purifying respirator. The Elipse OVAG P100 may be appropriate for low-concentration isocyanate applications below defined thresholds, but this determination requires professional industrial hygiene evaluation.

Can the Elipse mask be used with a beard or significant facial hair?

No tight-fitting half mask — including the GVS Elipse — can achieve the face seal required for OSHA compliance when the user has beard growth along the face seal contact path. OSHA 29 CFR 1910.134 requires that a tight-fitting respirator not be worn when conditions prevent a proper face seal. Workers with beards who require respiratory protection must use a loose-fitting powered air-purifying respirator (PAPR) or supplied-air hood designed for use without a face seal.

Brand / Vendor
GVS
Model / SKU
SPR113J
Product Type
Half Mask Respirator
Price
$39.99 (Amazon)
Rating
4.8 / 5 — 567 reviews
Availability
✓ In Stock on Amazon
🏷️
No Paid Placements
Every product earns its place based on safety credentials and field performance, not advertising spend.
🏭
Industrial Grade Only
Products sourced for professional use in manufacturing, construction, and industrial environments.
🔬
Compliance Verified
Every product listed on WC Safety is reviewed for standards compliance and safety credentials before publication.
🏭
Sourced for Professionals
Gear selected for safety managers, procurement teams, and field supervisors — not casual consumers.
Share Your Experience

Write a Review

Select a rating

Thank you for your review!

Your submission has been received and will be published after verification.

GVS Elipse OVAG P100 NIOSH Half Mask Respirator – Organic Vapor, Acid Gas & Particulate