{"product_id":"moldex-7200-acid-gas-respirator-cartridge","title":"Moldex 7200 Acid Gas Respirator Cartridge","description":"\u003cdiv class=\"product-description-rich\"\u003e\n\n\u003c!-- [0] EDITORIAL REVIEW BOX --\u003e\n\u003cdiv class=\"wc-review-box\" style=\"border:2px solid #ff9800;background:#2a2520;border-radius:8px;padding:20px 24px;margin:0 0 24px 0;color:#f5e6d3;\"\u003e\n  \u003cdiv style=\"margin-bottom:12px;\"\u003e\u003cspan style=\"background:#ff9800;color:#1a1a1a;font-weight:bold;padding:4px 12px;border-radius:4px;font-size:0.95em;\"\u003eEDITORIAL REVIEW: 4.1\/5\u003c\/span\u003e\u003c\/div\u003e\n  \u003cp\u003e\u003cstrong\u003eBest For:\u003c\/strong\u003e Workers with dedicated acid gas exposure — hydrogen chloride, sulfur dioxide, chlorine, hydrogen fluoride, and hydrogen sulfide — in chemical processing, laboratory environments, electroplating, pulp and paper operations, and industrial cleaning where organic vapor is not a co-hazard.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eNot For:\u003c\/strong\u003e Oxygen-deficient atmospheres, IDLH concentrations, organic vapor hazards (solvents, paint fumes), particulates without an added P100 filter, or any atmosphere where a supplied-air respirator (SCBA) is required. Not a replacement for the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300 OV+AG cartridge\u003c\/a\u003e in mixed-hazard environments.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eBottom Line:\u003c\/strong\u003e The 7200 is the right cartridge when your SDS or industrial hygienist flags acid gases as the sole chemical hazard — its high sorbent density earns the premium price, but buyers with both organic vapor and acid gas exposure should step up to the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300\u003c\/a\u003e instead.\u003c\/p\u003e\n  \u003cp style=\"font-size:0.9em;color:#cbb89e;\"\u003eEditorial assessment by WC Safety. Scoring reflects manufacturer specifications, application fit, and compatibility — not laboratory testing.\u003c\/p\u003e\n  \u003cp style=\"margin-top:12px;\"\u003e\u003ca href=\"\/blogs\/product-reviews\/moldex-7200-acid-gas-respirator-cartridge-review\" title=\"Read our full Moldex 7200 review\" style=\"color:#4fc3f7;font-size:0.95em;text-decoration:underline;\"\u003eRead our full Moldex 7200 review →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- [1] OVERVIEW --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 Overview\u003c\/h2\u003e\n\u003cp\u003eThe Moldex 7200 is a NIOSH-approved acid gas respirator cartridge, sold as a pair, that attaches via bayonet connection to \u003ca href=\"\/products\/moldex-7000-series-half-mask-respirator-7001-7002-7003\" style=\"color:#4fc3f7;\"\u003eMoldex 7000 series half-mask respirators\u003c\/a\u003e, \u003ca href=\"\/collections\/moldex-half-mask-respirator\" style=\"color:#4fc3f7;\"\u003eMoldex 8000 and other half-mask platforms\u003c\/a\u003e, and \u003ca href=\"\/products\/moldex-9000-series-full-face-respirator-9001-9002-9003\" style=\"color:#4fc3f7;\"\u003eMoldex 9000 series full-face respirators\u003c\/a\u003e. It uses a chemically-treated activated carbon bed specifically engineered for acid gas breakthrough resistance, protecting against hydrogen chloride, chlorine, hydrogen fluoride, sulfur dioxide, and hydrogen sulfide at concentrations up to 10× the OSHA permissible exposure limit. At $36.23 per pair, the 7200's higher price relative to the OV family reflects a denser sorbent loading tuned for acid gas molecules rather than organic vapors — this is not a multi-purpose cartridge, and that precision is the point.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;gap:12px;flex-wrap:wrap;margin:16px 0;\"\u003e\n  \u003ca href=\"\/collections\/moldex-respirator-cartridges-and-filters\" style=\"background:#ff9800;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\"\u003eShop Moldex Cartridges\u003c\/a\u003e\n  \u003ca href=\"https:\/\/www.amazon.com\/dp\/B015MG3Y2C?tag=wcsafety04-20\" style=\"background:#FF9900;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\" rel=\"nofollow sponsored\"\u003eBuy on Amazon →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:0.8em;color:#888;font-style:italic;\"\u003eAffiliate disclosure: WC Safety earns a commission on qualifying Amazon purchases at no extra cost to you.\u003c\/p\u003e\n\n\u003c!-- [2] WHERE IT FITS IN RESPIRATOR SELECTION --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eWhere the Moldex 7200 Fits in Respirator Selection\u003c\/h2\u003e\n\u003cp\u003eRespirator cartridge selection starts with hazard identification, not brand preference. Before ordering the 7200, your SDS or industrial hygienist report needs to confirm that acid gases are the primary or sole chemical hazard in your work area. If the hazard list also includes organic solvents, paint fumes, or other vapors, the 7200 will leave you unprotected — the correct choice is the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300 OV+AG cartridge\u003c\/a\u003e or the \u003ca href=\"\/products\/moldex-7367-organic-vapor-acid-gas-p100-combo-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7367 OV+AG+P100 combo\u003c\/a\u003e for environments that also have airborne particulates.\u003c\/p\u003e\n\n\u003cp\u003eThe 7200 occupies the dedicated acid gas slot in the Moldex cartridge lineup. It provides no organic vapor protection whatsoever — its carbon bed is chemically-treated specifically for acid gas adsorption, which is why it outperforms general-purpose combination cartridges in pure acid gas scenarios. For workers comparing cartridge classes, our \u003ca href=\"\/blogs\/guides\/p95-vs-r95-vs-p100-filter-class-guide\" style=\"color:#4fc3f7;\"\u003eP95 vs R95 vs P100 filter class guide\u003c\/a\u003e explains how filter ratings interact with cartridge protection levels, and our \u003ca href=\"\/blogs\/guides\/respirator-cartridge-esli-guide\" style=\"color:#4fc3f7;\"\u003eESLI guide\u003c\/a\u003e covers how to manage change schedules on cartridges without end-of-service-life indicators like this one. Buyers evaluating whether a nuisance-relief cartridge is sufficient for their acid gas exposure should read our \u003ca href=\"\/blogs\/guides\/nuisance-relief-vs-rated-respirator-protection\" style=\"color:#4fc3f7;\"\u003enuisance relief vs. rated protection explainer\u003c\/a\u003e before purchasing.\u003c\/p\u003e\n\n\u003cp\u003eIf your facility uses 3M respirators and you are evaluating cross-brand options, our \u003ca href=\"\/blogs\/guides\/best-3m-respirator-cartridges\" style=\"color:#4fc3f7;\"\u003ebest 3M respirator cartridges guide\u003c\/a\u003e and the \u003ca href=\"\/blogs\/guides\/3m-vs-honeywell-north-respirator-cartridges\" style=\"color:#4fc3f7;\"\u003e3M vs. Honeywell North cartridge comparison\u003c\/a\u003e provide context — though cartridges are brand-locked and the 7200 fits Moldex respirators only.\u003c\/p\u003e\n\n\u003c!-- [3] WHO SHOULD BUY --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eWho Should Buy the Moldex 7200?\u003c\/h2\u003e\n\n\u003cdiv style=\"background:#2a2520;border-radius:8px;padding:20px 24px;margin:0 0 24px 0\"\u003e\n\u003ch3 style=\"color:#ffb74d;\"\u003eBuy the Moldex 7200 if you:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlready own a \u003ca href=\"\/products\/moldex-7000-series-half-mask-respirator-7001-7002-7003\" style=\"color:#4fc3f7;\"\u003eMoldex 7000 series half-mask\u003c\/a\u003e or \u003ca href=\"\/products\/moldex-9000-series-full-face-respirator-9001-9002-9003\" style=\"color:#4fc3f7;\"\u003eMoldex 9000 series full-face respirator\u003c\/a\u003e and need acid gas cartridges\u003c\/li\u003e\n  \u003cli\u003eWork in chemical manufacturing, electroplating, pulp and paper, semiconductor fabrication, or laboratory settings where HCl, Cl₂, HF, SO₂, or H₂S are the documented hazards\u003c\/li\u003e\n  \u003cli\u003eNeed dedicated acid gas protection without organic vapor capability — the single-function design maximizes sorbent bed depth for acid gas molecules\u003c\/li\u003e\n  \u003cli\u003eAre replacing cartridges on a Moldex respirator after reaching your change schedule interval\u003c\/li\u003e\n  \u003cli\u003eWant to buy pairs rather than single cartridges — the 7200 pair format ensures matched replacement of both cartridges simultaneously\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eDo NOT buy the Moldex 7200 if you:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHave \u003cstrong\u003eboth organic vapors and acid gases\u003c\/strong\u003e in your work area — use the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300 OV+AG pair\u003c\/a\u003e or \u003ca href=\"\/products\/moldex-7307-organic-vapor-acid-gas-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003e7307 single\u003c\/a\u003e instead\u003c\/li\u003e\n  \u003cli\u003eWork around \u003cstrong\u003eammonia or methylamine\u003c\/strong\u003e — those require the \u003ca href=\"\/products\/moldex-7400-ammonia-methylamine-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7400 AM cartridge\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003eNeed \u003cstrong\u003emulti-gas protection\u003c\/strong\u003e with a Smart ESLI — the \u003ca href=\"\/products\/moldex-7600-multi-gas-vapor-smart-cartridges\" style=\"color:#4fc3f7;\"\u003eMoldex 7600 Multi-Gas Smart pair\u003c\/a\u003e covers a broader hazard profile with an end-of-service-life indicator\u003c\/li\u003e\n  \u003cli\u003eUse a \u003cstrong\u003enon-Moldex respirator\u003c\/strong\u003e — the 7200 bayonet fitting is brand-specific and will not attach to 3M, Honeywell North, MSA, or any other manufacturer's facepiece\u003c\/li\u003e\n  \u003cli\u003eNeed \u003cstrong\u003ecombined particulate and acid gas protection\u003c\/strong\u003e — add a \u003ca href=\"\/products\/moldex-7740-p100-particulate-filter-respirator\" style=\"color:#4fc3f7;\"\u003eMoldex 7740 P100 filter\u003c\/a\u003e or upgrade to the \u003ca href=\"\/products\/moldex-7367-organic-vapor-acid-gas-p100-combo-cartridge\" style=\"color:#4fc3f7;\"\u003e7367 OV+AG+P100 combo\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- [4] WHAT IT PROTECTS AGAINST --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eWhat Does the Moldex 7200 Protect Against?\u003c\/h2\u003e\n\u003cp\u003eThe 7200 is NIOSH-approved for acid gas service. The table below maps each covered hazard to its protection level and buyer guidance:\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eHazard\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eProtection Level\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eBuyer Guidance\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved acid gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePrimary use case; common in chemical manufacturing and pool chemical handling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eChlorine (Cl₂)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved acid gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePulp\/paper bleaching, water treatment, industrial cleaning operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved acid gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSemiconductor fab, glass etching, aluminum smelting; confirm concentration is below IDLH (30 ppm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSulfur Dioxide (SO₂)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved acid gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePetroleum refining, food preservation, wine production, combustion atmospheres\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHydrogen Sulfide (H₂S)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved acid gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eWastewater treatment, oil and gas, confined space entry at non-IDLH levels only\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSulfuric Acid Mist\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAcid gas coverage\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eBattery manufacturing, electroplating; add P100 filter for mist particulates\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- [5] WHAT IT DOES NOT PROTECT AGAINST --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eWhat the Moldex 7200 Does NOT Protect Against\u003c\/h2\u003e\n\u003cp\u003eThe 7200 acid gas cartridge provides \u003cstrong\u003ezero protection\u003c\/strong\u003e against the following hazard categories:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrganic vapors\u003c\/strong\u003e — solvents, paint fumes, gasoline vapors, acetone, toluene, xylene, and similar chemicals require an OV-rated cartridge such as the \u003ca href=\"\/products\/moldex-7100-organic-vapor-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7100\u003c\/a\u003e or, for combined OV+AG hazards, the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmmonia and methylamine\u003c\/strong\u003e — these alkaline gases require the \u003ca href=\"\/products\/moldex-7400-ammonia-methylamine-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7400 AM cartridge\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirborne particulates\u003c\/strong\u003e — dusts, mists, metal fumes, and aerosols require a P100 filter; the \u003ca href=\"\/products\/moldex-7367-organic-vapor-acid-gas-p100-combo-cartridge\" style=\"color:#4fc3f7;\"\u003e7367 combo cartridge\u003c\/a\u003e combines OV+AG+P100 in one unit if particulates are also present\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCarbon monoxide and other gases not in the acid gas class\u003c\/strong\u003e — multi-gas environments require the \u003ca href=\"\/products\/moldex-7600-multi-gas-vapor-smart-cartridges\" style=\"color:#4fc3f7;\"\u003eMoldex 7600 Multi-Gas Smart cartridge\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMercury vapor\u003c\/strong\u003e — requires a specialized mercury vapor cartridge; see our \u003ca href=\"\/blogs\/guides\/best-respirator-cartridge-for-mercury-vapor\" style=\"color:#4fc3f7;\"\u003ebest cartridge for mercury vapor guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv style=\"background:#2a2520;border-radius:8px;padding:20px 24px;margin:0 0 24px 0;border-left:4px solid #ff9800;\"\u003e\n  \u003cp\u003e\u003cstrong style=\"color:#ff9800;\"\u003eCritical Safety Limitation:\u003c\/strong\u003e Air-purifying respirators including the Moldex 7200 are not approved for use in oxygen-deficient atmospheres (below 19.5% O₂), immediately dangerous to life or health (IDLH) concentrations, or any confined space or emergency scenario requiring supplied-air or self-contained breathing apparatus (SCBA). If atmospheric oxygen content is unknown or below threshold, or if gas concentrations may exceed cartridge capacity, stop work and consult your safety officer before entering.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- [6] BEST APPLICATIONS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eBest Applications for the Moldex 7200\u003c\/h2\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eChemical Manufacturing and Processing\u003c\/h3\u003e\n\u003cp\u003eFacilities producing or handling chlorine compounds, sulfuric acid, hydrochloric acid, or hydrofluoric acid are the 7200's home environment. Workers at reaction vessels, transfer stations, or acid storage areas where HCl or Cl₂ are the documented airborne hazards benefit from the 7200's dedicated sorbent bed. Pair with the \u003ca href=\"\/collections\/moldex-half-mask-respirator\" style=\"color:#4fc3f7;\"\u003eappropriate Moldex half-mask respirator\u003c\/a\u003e and verify concentrations are within cartridge service capacity before entry.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003ePulp and Paper \/ Water Treatment\u003c\/h3\u003e\n\u003cp\u003eBleaching operations in pulp mills release chlorine and chlorine dioxide; water treatment facilities use chlorine gas for disinfection. The 7200 is a standard-issue cartridge in both industries for routine maintenance and monitoring tasks where chlorine gas exposure is the primary concern. Confirm your industrial hygienist's air sampling data before selecting cartridge change intervals, as chlorine concentrations can vary significantly during process upsets.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eSemiconductor Fabrication and Electronics\u003c\/h3\u003e\n\u003cp\u003eWet etch processes and cleaning operations in semiconductor fabs frequently involve HF, HCl, and HNO₃ vapors. The 7200 is appropriate for routine fab maintenance tasks at non-IDLH HF concentrations. Given HF's severe systemic toxicity, facilities should cross-reference ACGIH TLV data and confirm SCBA requirements for higher-concentration scenarios before relying on air-purifying cartridges.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eElectroplating and Metal Finishing\u003c\/h3\u003e\n\u003cp\u003eAcid pickling, anodizing, and electroplating baths release HCl, H₂SO₄ mist, and other acid vapors. The 7200 handles the acid gas component; add a \u003ca href=\"\/products\/moldex-7740-p100-particulate-filter-respirator\" style=\"color:#4fc3f7;\"\u003eMoldex 7740 P100 filter\u003c\/a\u003e if mist or fume particulates are also present. The \u003ca href=\"\/collections\/moldex-respirator-cartridges-and-filters\" style=\"color:#4fc3f7;\"\u003efull Moldex cartridge and filter collection\u003c\/a\u003e has compatible components for combined hazard configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eLaboratory and Research Environments\u003c\/h3\u003e\n\u003cp\u003eLabs handling strong acids, conducting acid digestions, or working with chlorinated solvents use the 7200 for short-duration tasks outside the fume hood. Institutional safety officers should confirm that air-purifying cartridges are permissible under their lab safety program and that concentrations remain well below IDLH thresholds for each acid gas present.\u003c\/p\u003e\n\n\u003c!-- [7] PROS \/ CONS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003ePros and Cons\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;width:50%;\"\u003ePros\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;width:50%;\"\u003eCons\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHigh sorbent density optimized specifically for acid gas molecules — deeper service life than combination cartridges in pure acid gas environments\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNo organic vapor protection — wrong cartridge for mixed OV+AG hazards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved; covers HCl, Cl₂, HF, SO₂, and H₂S in a single cartridge\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNo ESLI — change schedule must be managed by employer program or odor detection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eTool-free bayonet attachment; fast change in the field\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePremium price ($36.23\/pair) versus combination cartridges\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH color-coded (green) for easy identification and compliance audits\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMoldex-only fit — incompatible with all other respirator brands\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSold as a pair — ensures matched simultaneous replacement of both cartridges\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNo single-cartridge SKU available on WC Safety — minimum purchase is a pair\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- [8] COMPATIBLE RESPIRATORS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eCompatible Moldex Respirators\u003c\/h2\u003e\n\u003cp\u003eThe Moldex 7200 uses Moldex's standard bayonet\/threaded connection system and is compatible with the following Moldex respirator series:\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eRespirator Series\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eType\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eCompatible?\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eNotes\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7000-series-half-mask-respirator-7001-7002-7003\" style=\"color:#4fc3f7;\"\u003eMoldex 7000 Series (7001\/7002\/7003)\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHalf-mask\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eStandard bayonet fit; sizes S\/M\/L\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMoldex 8000 Series\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHalf-mask\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSame bayonet connection as 7000 series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-9000-series-full-face-respirator-9001-9002-9003\" style=\"color:#4fc3f7;\"\u003eMoldex 9000 Series (9001\/9002\/9003)\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eFull-face\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eRecommended for HF and high acid gas concentrations requiring eye protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e3M, Honeywell North, MSA, Scott, or any other brand\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAny\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✗ No\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eBayonet fitting is Moldex-proprietary; physical fit failure creates an unprotected seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThe Moldex 7200 does NOT fit any non-Moldex respirator.\u003c\/strong\u003e Attempting to force-fit incompatible cartridges voids NIOSH approval and eliminates the facepiece seal — never mix cartridge and respirator brands.\u003c\/p\u003e\n\n\u003c!-- [9] 7200 vs OTHER MOLDEX CARTRIDGES --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 vs. Other Moldex Cartridges\u003c\/h2\u003e\n\u003cp\u003eEvery Moldex cartridge in the 7-series uses the same bayonet connection. The differences are in the sorbent chemistry and hazard coverage. Choose based on your SDS hazard assessment:\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eCartridge\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eHazard Coverage\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eFormat\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003ePrice\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eChoose When\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\n\u003cstrong\u003e7200\u003c\/strong\u003e (this item)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAcid Gas only\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$36.23\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePure acid gas hazard, no OV present\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7100-organic-vapor-cartridge\" style=\"color:#4fc3f7;\"\u003e7100\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eOrganic Vapor only\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$19.09\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSolvents, paint fumes, no acid gases\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003e7300\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eOV + Acid Gas\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$18.73\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMixed OV+AG environments; most common combination\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7367-organic-vapor-acid-gas-p100-combo-cartridge\" style=\"color:#4fc3f7;\"\u003e7367\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eOV + AG + P100\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSet\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$11.62\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eOV+AG+particulates in one unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7400-ammonia-methylamine-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003e7400\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAmmonia \/ Methylamine\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$33.58\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eRefrigerant leaks, agricultural, fertilizer facilities\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e\u003ca href=\"\/products\/moldex-7600-multi-gas-vapor-smart-cartridges\" style=\"color:#4fc3f7;\"\u003e7600\u003c\/a\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMulti-Gas + Smart ESLI\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$20.79\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eBroadest vapor coverage with end-of-service-life indicator\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- [10] 7200 vs 7300 HEAD-TO-HEAD --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 vs. Moldex 7300: Which Acid Gas Cartridge Do You Need?\u003c\/h2\u003e\n\u003cp\u003eThis is the most common comparison question on the 7200. Both cartridges protect against acid gases — but the 7300 also covers organic vapors, and it costs less ($18.73 vs. $36.23 per pair).\u003c\/p\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003e\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eMoldex 7200\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003e\u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#ffb74d;\"\u003eMoldex 7300\u003c\/a\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAcid Gas Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eOrganic Vapor Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✗ No\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e✓ Yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePrice per Pair\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$36.23\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$18.73\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSorbent Density for AG\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHigher — dedicated AG bed\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eShared OV+AG sorbent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eBest For\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePure acid gas environments only\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMixed or uncertain OV+AG environments\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eBuy verdict:\u003c\/strong\u003e If your SDS lists only acid gases with no organic vapor co-hazard, the 7200's dedicated sorbent bed is the technically correct choice and its higher price reflects longer acid gas service capacity per cartridge. If there is any possibility of organic vapor exposure — even occasional — choose the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300\u003c\/a\u003e at the lower price point. When in doubt, the 7300 is the safer default for facilities without a formal industrial hygiene program.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;gap:12px;flex-wrap:wrap;margin:16px 0;\"\u003e\n  \u003ca href=\"https:\/\/www.amazon.com\/dp\/B015MG3Y2C?tag=wcsafety04-20\" style=\"background:#FF9900;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\" rel=\"nofollow sponsored\"\u003eBuy Moldex 7200 on Amazon →\u003c\/a\u003e\n  \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"background:#ff9800;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\"\u003eSee Moldex 7300 Instead\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- [11] QUICK ANSWERS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 Quick Answers\u003c\/h2\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eWhat respirators does the Moldex 7200 fit?\u003c\/h3\u003e\n\u003cp\u003eThe Moldex 7200 fits all Moldex 7000, 8000, and 9000 series respirators using the standard Moldex bayonet connection. It does not fit any 3M, Honeywell North, MSA, or other brand respirator — Moldex's bayonet fitting is proprietary.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eDoes the Moldex 7200 protect against organic vapors?\u003c\/h3\u003e\n\u003cp\u003eNo. The Moldex 7200 is an acid gas-only cartridge with no organic vapor protection. Workers exposed to solvents, paint fumes, or other organic vapors must use the \u003ca href=\"\/products\/moldex-7100-organic-vapor-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7100 OV cartridge\u003c\/a\u003e or the \u003ca href=\"\/products\/moldex-7300-organic-vapor-acid-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7300 OV+AG combination cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eDoes the Moldex 7200 have an ESLI?\u003c\/h3\u003e\n\u003cp\u003eNo. The Moldex 7200 does not include an end-of-service-life indicator. Change schedules must be established through an employer-maintained respiratory protection program per OSHA 29 CFR 1910.134, based on industrial hygiene data, manufacturer service-life information, or odor breakthrough detection. The \u003ca href=\"\/blogs\/guides\/respirator-cartridge-esli-guide\" style=\"color:#4fc3f7;\"\u003eMoldex Smart ESLI cartridges\u003c\/a\u003e (7600\/7607 series) offer indicator-based change notification for multi-gas environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eHow many cartridges come in a Moldex 7200 package?\u003c\/h3\u003e\n\u003cp\u003eEach package contains two cartridges (one pair). Both cartridges should be replaced simultaneously at each change interval to maintain balanced airflow resistance across the respirator.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eIs the Moldex 7200 NIOSH approved?\u003c\/h3\u003e\n\u003cp\u003eYes. The Moldex 7200 is NIOSH-approved for acid gas service. NIOSH color-coding for acid gas cartridges is green, which the 7200 carries for compliance identification during workplace respiratory protection audits.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eWhy is the Moldex 7200 more expensive than the 7300?\u003c\/h3\u003e\n\u003cp\u003eThe Moldex 7200's higher price reflects a dedicated acid gas sorbent bed with greater sorbent density than the dual-purpose 7300. In a pure acid gas environment, the 7200 provides longer service life per cartridge because the entire sorbent capacity is allocated to acid gas adsorption rather than being shared with an organic vapor layer.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eCan the Moldex 7200 be used for hydrogen fluoride?\u003c\/h3\u003e\n\u003cp\u003eYes, the Moldex 7200 is rated for hydrogen fluoride (HF) as an acid gas cartridge. Given HF's systemic toxicity and low IDLH threshold (30 ppm), confirm that workplace concentrations are within the cartridge's service range and that air-purifying respirators are permissible under your facility's safety plan before use.\u003c\/p\u003e\n\n\u003c!-- [12] SPECIFICATIONS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;background:#1a1a1a;color:#e0e0e0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"color:#ffb74d;padding:8px;text-align:left;border-bottom:1px solid #333;\"\u003eDetail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSKU \/ Model Number\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e7200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMoldex\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eCartridge Type\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eChemical Cartridge — Acid Gas only\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH Approval\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH-approved, Acid Gas (AG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNIOSH Color Code\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eGreen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHazards Covered\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eHydrogen Chloride, Chlorine, Hydrogen Fluoride, Sulfur Dioxide, Hydrogen Sulfide\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eSorbent Technology\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eChemically-treated activated carbon, acid gas optimized\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eESLI\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eNone — employer change schedule required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eConnection Type\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMoldex bayonet (proprietary)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eCompatible Platforms\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eMoldex 7000, 8000, 9000 series respirators\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePack Size\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePair (2 cartridges per package)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003ePrice (WC Safety)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e$36.23 per pair\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eAmazon ASIN\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eB015MG3Y2C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003eGTIN \/ UPC\u003c\/td\u003e\n      \u003ctd style=\"padding:8px;border-bottom:1px solid #2a2a2a;\"\u003e0092311720005\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"display:flex;gap:12px;flex-wrap:wrap;margin:16px 0;\"\u003e\n  \u003ca href=\"https:\/\/www.amazon.com\/dp\/B015MG3Y2C?tag=wcsafety04-20\" style=\"background:#FF9900;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\" rel=\"nofollow sponsored\"\u003eBuy Moldex 7200 on Amazon →\u003c\/a\u003e\n  \u003ca href=\"\/collections\/moldex-respirator-cartridges-and-filters\" style=\"background:#ff9800;color:#1a1a1a;padding:10px 20px;border-radius:4px;font-weight:bold;text-decoration:none;\"\u003eBrowse All Moldex Cartridges\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- [13] HELPFUL BUYING GUIDES --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eHelpful Buying Guides\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/p95-vs-r95-vs-p100-filter-class-guide\" style=\"color:#4fc3f7;\"\u003eP95 vs. R95 vs. P100 — Understanding Filter Classes for Respirator Cartridges\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/respirator-cartridge-esli-guide\" style=\"color:#4fc3f7;\"\u003eRespirator Cartridge ESLI Guide — When to Change Your Cartridge\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/nuisance-relief-vs-rated-respirator-protection\" style=\"color:#4fc3f7;\"\u003eNuisance Relief vs. Rated Cartridge Protection — What the Difference Means for Your Safety\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/best-3m-respirator-cartridges\" style=\"color:#4fc3f7;\"\u003eBest 3M Respirator Cartridges — Cross-Brand Comparison Guide\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/3m-vs-honeywell-north-respirator-cartridges\" style=\"color:#4fc3f7;\"\u003e3M vs. Honeywell North Respirator Cartridges — Full Comparison\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/guides\/best-respirator-cartridge-for-mercury-vapor\" style=\"color:#4fc3f7;\"\u003eBest Respirator Cartridge for Mercury Vapor\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- [14] FREQUENTLY ASKED QUESTIONS --\u003e\n\u003ch2 style=\"color:#ff9800;\"\u003eMoldex 7200 Frequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eIs there a single-cartridge version of the Moldex 7200?\u003c\/h3\u003e\n\u003cp\u003eWC Safety does not currently carry a single-cartridge acid gas-only SKU in the Moldex line. The 7200 is sold as a pair only. If cost per cartridge is a priority, note that the \u003ca href=\"\/products\/moldex-7307-organic-vapor-acid-gas-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7307\u003c\/a\u003e is available as a single cartridge with OV+AG coverage at $8.80 — though it adds organic vapor protection you may not need.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eHow often should I replace the Moldex 7200?\u003c\/h3\u003e\n\u003cp\u003eThe Moldex 7200 has no ESLI. Replacement frequency must be determined by your employer's respiratory protection program per OSHA 29 CFR 1910.134(d)(3)(iii)(B)(2), factoring in gas concentration, temperature, humidity, workload, and cartridge exposure time. Replace immediately upon detecting odor, increased breathing resistance, or any sign of physical damage to the cartridge body.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eCan the Moldex 7200 be used with the Moldex 9000 full-face respirator for HF work?\u003c\/h3\u003e\n\u003cp\u003eYes, the 7200 is physically and chemically compatible with the \u003ca href=\"\/products\/moldex-9000-series-full-face-respirator-9001-9002-9003\" style=\"color:#4fc3f7;\"\u003eMoldex 9000 series full-face respirator\u003c\/a\u003e. Full-face use is strongly recommended for hydrofluoric acid work because HF vapor causes severe eye and mucous membrane irritation. Confirm concentration levels are within the respirator's assigned protection factor and below HF IDLH before using an air-purifying system.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eDoes the Moldex 7200 protect against chlorine dioxide?\u003c\/h3\u003e\n\u003cp\u003eChlorine dioxide (ClO₂) is a distinct compound from chlorine (Cl₂). The 7200 is NIOSH-approved for chlorine (Cl₂) as an acid gas, but ClO₂ requires verification against the specific NIOSH approval test conditions. Consult Moldex technical documentation or your industrial hygienist before using the 7200 in confirmed chlorine dioxide atmospheres.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eWhat is the difference between the Moldex 7200 and Moldex 7600 cartridges?\u003c\/h3\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/moldex-7600-multi-gas-vapor-smart-cartridges\" style=\"color:#4fc3f7;\"\u003eMoldex 7600\u003c\/a\u003e covers a broader multi-gas hazard profile and includes Moldex's Smart ESLI end-of-service-life indicator. The 7200 covers acid gases only with no ESLI, but its dedicated acid gas sorbent bed provides a deeper capacity for acid gas molecules specifically. Choose the 7600 for multi-gas environments or when a change indicator is required by your safety program.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eCan I add a P100 filter to the Moldex 7200 for combined acid gas and particulate protection?\u003c\/h3\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/moldex-7740-p100-particulate-filter-respirator\" style=\"color:#4fc3f7;\"\u003eMoldex 7740 P100 filter\u003c\/a\u003e can be mounted over the 7200 cartridge on compatible Moldex respirators to provide concurrent particulate protection. Alternatively, the \u003ca href=\"\/products\/moldex-7367-organic-vapor-acid-gas-p100-combo-cartridge\" style=\"color:#4fc3f7;\"\u003eMoldex 7367 OV+AG+P100 combo\u003c\/a\u003e integrates all three in a single unit, though it adds OV coverage you may not require.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eIs the Moldex 7200 appropriate for pool chemical handling?\u003c\/h3\u003e\n\u003cp\u003ePool chemical work involving chlorine gas, sodium hypochlorite off-gassing, or muriatic acid (HCl) falls squarely within the 7200's protection profile. The cartridge is rated for both chlorine and hydrogen chloride. Verify that ambient concentrations are confirmed below IDLH and that oxygen levels are adequate before using an air-purifying respirator in enclosed pool mechanical rooms.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eHow do I know the Moldex 7200 is properly seated on my respirator?\u003c\/h3\u003e\n\u003cp\u003eAfter inserting the 7200 into the bayonet fitting, rotate clockwise until the cartridge clicks and locks. Perform a negative-pressure user seal check: place your palms over both cartridges, inhale gently, and hold for 10 seconds. The facepiece should collapse slightly and hold without air leaking in. A failed seal check requires refitting or replacing the respirator — do not enter the work area with a failed seal.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eCan the Moldex 7200 cartridge be stored for future use after opening?\u003c\/h3\u003e\n\u003cp\u003eOpened and partially used acid gas cartridges should not be stored for extended periods because the activated carbon continues to adsorb airborne contaminants even when not in active use. Store opened cartridges in a sealed plastic bag away from chemical storage areas and heat sources. Follow your employer's written change-schedule policy for maximum storage time between uses.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eDoes buying a pair mean both cartridges are identical?\u003c\/h3\u003e\n\u003cp\u003eYes. Each package contains two identical Moldex 7200 acid gas cartridges intended for simultaneous use on both sides of the respirator facepiece. They should always be changed together — replacing only one cartridge creates unequal resistance across the two inhalation ports and may reduce protection on the older side.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eWhat OSHA regulation governs use of the Moldex 7200?\u003c\/h3\u003e\n\u003cp\u003eThe Moldex 7200 is used under OSHA's Respiratory Protection Standard, 29 CFR 1910.134. Employers must maintain a written respiratory protection program including hazard assessment, medical evaluation, fit testing, training, and a cartridge change schedule before requiring or permitting employees to use air-purifying cartridge respirators.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eIs the Moldex 7200 available in a multi-pack for high-volume facilities?\u003c\/h3\u003e\n\u003cp\u003eWC Safety sells the Moldex 7200 in the standard pair format. For high-volume purchases or B2B procurement of cartridges across multiple work areas, contact WC Safety directly. The \u003ca href=\"\/collections\/moldex-respirator-cartridges-and-filters\" style=\"color:#4fc3f7;\"\u003efull Moldex cartridge collection\u003c\/a\u003e is available for bulk review online.\u003c\/p\u003e\n\n\u003c!-- [15] FOOTER E-E-A-T TRUST BLOCK --\u003e\n\u003cdiv style=\"border-top:1px solid #333;margin-top:32px;padding-top:16px;font-size:0.85em;color:#888;\"\u003e\n  \u003cp\u003eWritten by \u003cstrong\u003eSteven Eaton\u003c\/strong\u003e, WC Safety Editorial — Industrial hygiene \u0026amp; PPE specialist, 10+ years respiratory protection sourcing.\u003c\/p\u003e\n  \u003cp\u003eReviewed by the WC Safety Editorial Team. Last reviewed June 2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c!-- WCS-COMPARISON-LINKS --\u003e\n\u003cdiv style=\"background:#1a2733;border:1px solid #2a3f50;border-radius:4px;padding:20px 22px;margin:28px 0 0 0;\"\u003e\n\u003cp style=\"color:#4fc3f7;font-weight:bold;margin:0 0 10px 0;font-size:0.85em;text-transform:uppercase;letter-spacing:0.05em;\"\u003eWC Safety Comparison \u0026amp; Selection Guides\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px;color:#e0e0e0;line-height:1.9em;\"\u003e\n\u003cli style=\"margin-bottom:6px;\"\u003e\u003ca href=\"\/blogs\/guides\/ov-vs-ov-ag-vs-multi-gas-cartridge-guide\" title=\"OV vs OV+AG vs Multi-Gas Selection Guide\" style=\"color:#4fc3f7;text-decoration:underline;\"\u003eOV vs OV+AG vs Multi-Gas Selection Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"margin-bottom:6px;\"\u003e\u003ca href=\"\/blogs\/guides\/esli-vs-written-change-schedule-respirator-guide\" title=\"ESLI vs Written Change Schedule Guide\" style=\"color:#4fc3f7;text-decoration:underline;\"\u003eESLI vs Written Change Schedule Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Moldex","offers":[{"title":"Default Title","offer_id":43925080473688,"sku":"Moldex 7200","price":36.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0594\/1900\/0920\/files\/615lgAJHlmL.jpg?v=1774810420","url":"https:\/\/wcsafety.com\/products\/moldex-7200-acid-gas-respirator-cartridge","provider":"WC Safety","version":"1.0","type":"link"}