{"product_id":"kidde-kn-cob-dp2-plug-in-carbon-monoxide-alarm-battery-backup-digital-display","title":"Kidde KN-COB-DP2 Plug-In Carbon Monoxide Alarm with Battery Backup and Digital Display","description":"\u003ch2\u003eKidde KN-COB-DP2 Plug-In CO Alarm with Battery Backup: At a Glance\u003c\/h2\u003e\n\u003cp\u003eThe Kidde KN-COB-DP2 is a plug-in carbon monoxide alarm that combines the convenience of AC outlet power with the critical resilience of a 9V battery backup — plus a digital display showing real-time CO concentration in parts per million (PPM). This dual-power design makes the KN-COB-DP2 one of the most versatile CO alarms in the Kidde lineup: it operates on AC power under normal conditions, then seamlessly switches to battery backup during power outages — exactly when CO risk from portable generators, fuel-powered heaters, or backup appliances is at its highest. UL 2034 listed and engineered by Kidde, a Carrier company, the KN-COB-DP2 delivers uninterrupted CO protection for hotels, rental properties, offices, commercial kitchens, and any occupancy where power reliability and continuous digital monitoring are both priorities.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e AC plug-in (120V) with 9V battery backup\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Digital LED showing CO concentration in PPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Backup:\u003c\/strong\u003e 9V battery (not included) for power outage protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL 2034 listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e KN-COB-DP2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Choose the Kidde KN-COB-DP2?\u003c\/h2\u003e\n\u003cp\u003eThe KN-COB-DP2 solves a critical gap that exists in most CO alarm installations: the period immediately after a power outage. When grid power fails, occupants and building managers often resort to generators, propane heaters, kerosene lamps, or gas stoves — all of which produce CO. This is precisely the moment when CO alarms must be most reliable, and it's the moment when plug-in-only CO alarms go completely offline. The KN-COB-DP2's 9V battery backup ensures CO monitoring continues without interruption regardless of grid status, providing protection during the highest-risk period of any power outage.\u003c\/p\u003e\n\u003cp\u003eCombined with the digital PPM display, the KN-COB-DP2 gives safety managers and facilities operators both continuous power and continuous visibility into actual CO levels. During normal operation, the digital readout confirms CO levels are safe during routine inspections. During a power outage or emergency, the battery-backed unit continues to display CO readings, enabling informed decision-making — particularly critical when emergency responders, property managers, or safety officers need to assess CO concentrations in a facility without electricity. For commercial customers managing properties with diverse occupant types (hotels, assisted living, multi-family housing), this combination of features represents a meaningful upgrade over both plug-in-only and battery-only alternatives.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAC plug-in design (120V) — installs in any standard outlet, no tools required\u003c\/li\u003e\n  \u003cli\u003e9V battery backup provides continuous CO protection during power outages\u003c\/li\u003e\n  \u003cli\u003eDigital LED display shows real-time CO concentration in PPM\u003c\/li\u003e\n  \u003cli\u003eAutomatic switchover from AC to battery power during outages\u003c\/li\u003e\n  \u003cli\u003eUL 2034 listed for compliance with U.S. CO alarm standards\u003c\/li\u003e\n  \u003cli\u003eElectrochemical sensor technology for precise, long-term CO detection\u003c\/li\u003e\n  \u003cli\u003ePeak CO memory records highest detected CO level for post-incident review\u003c\/li\u003e\n  \u003cli\u003eLow battery indicator alerts when backup battery needs replacement\u003c\/li\u003e\n  \u003cli\u003eTest\/reset button for scheduled safety inspections and compliance documentation\u003c\/li\u003e\n  \u003cli\u003e85 dB alarm for clear audible notification in occupied spaces\u003c\/li\u003e\n  \u003cli\u003eEnd-of-life indicator when unit requires replacement\u003c\/li\u003e\n  \u003cli\u003eManufactured by Kidde, a Carrier company with global CO safety expertise\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReal-World Benefits\u003c\/h3\u003e\n\u003cp\u003eFor hotel and hospitality operators, the KN-COB-DP2 addresses a liability scenario that basic plug-in CO alarms cannot: power outages caused by storms, equipment failures, or utility interruptions. During an outage, guests may use portable chargers, candles, or — most dangerously — indoor use of camping stoves or small generators. A CO alarm that goes offline with the power provides no protection in this scenario. The KN-COB-DP2's battery backup ensures alarms remain active throughout the outage, maintaining the continuous CO monitoring that life safety codes require and that guests and insurers expect.\u003c\/p\u003e\n\u003cp\u003eCommercial property managers and facilities directors overseeing multi-tenant buildings, offices, or retail centers benefit from the KN-COB-DP2's operational simplicity. Installation requires no electrician — simply plug in and insert the 9V battery backup. The digital display provides instant CO status confirmation during routine walkthroughs, and the battery backup indicator ensures facilities teams know when the backup battery needs attention. For documentation and compliance purposes, the peak CO memory supports post-incident reporting and OSHA record-keeping.\u003c\/p\u003e\n\u003cp\u003eIn regions prone to severe weather or utility disruptions, the KN-COB-DP2 is a practical upgrade over standard plug-in CO alarms for any facility with combustion appliances. Schools, community centers, and emergency shelters — facilities that may operate during power outages and where vulnerability is highest — benefit from knowing their CO detection does not depend on the grid.\u003c\/p\u003e\n\n\u003ch3\u003eApplications and Ideal Use Cases\u003c\/h3\u003e\n\u003cp\u003eThe Kidde KN-COB-DP2 is the optimal choice when plug-in convenience must be combined with power outage resilience and digital monitoring. Primary applications include hotel and motel guestrooms and common areas, multi-family residential buildings, assisted living and elder care facilities, school buildings and community centers, commercial offices with combustion HVAC or kitchen equipment, restaurant back-of-house areas, emergency shelters and community resilience centers, and any rental or occupied property in storm-prone regions where generator use during outages is common.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSKU \/ Model\u003c\/td\u003e\n\u003ctd\u003eKN-COB-DP2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKidde (a Carrier company)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e120V AC plug-in with 9V battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital LED, PPM readout\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInterconnect\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSensor Technology\u003c\/td\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL 2034\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAlarm Sound Level\u003c\/td\u003e\n\u003ctd\u003e85 dB at 10 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e40°F–100°F (4.4°C–37.8°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 120V outlet, plug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eRelated Products and Resources\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/co-detectors\"\u003eBrowse All CO Detectors at WC Safety\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/head-protection\"\u003eHead Protection Products\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/hearing-protection\"\u003eHearing Protection\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/collections\/disposable-respirators\"\u003eDisposable Respirators\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/blogs\/product-reviews\" style=\"color:#4fc3f7;\"\u003eWC Safety Product Reviews Blog\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does the battery backup on the KN-COB-DP2 work?\u003c\/h3\u003e\n\u003cp\u003eThe KN-COB-DP2 normally operates on 120V AC outlet power. When grid power is interrupted, the unit automatically switches to the 9V battery backup without any manual intervention, maintaining continuous CO monitoring and alarm capability throughout the outage. The battery backup is not included and must be installed before the unit is placed in service.\u003c\/p\u003e\n\u003ch3\u003eDoes the digital display work during a power outage when running on battery?\u003c\/h3\u003e\n\u003cp\u003eYes. The KN-COB-DP2's digital display continues to show CO concentration in PPM while operating on battery backup, providing uninterrupted monitoring visibility even during extended power outages. This is a critical feature for safety personnel assessing CO risk in facilities during emergency conditions.\u003c\/p\u003e\n\u003ch3\u003eIs the KN-COB-DP2 UL 2034 listed?\u003c\/h3\u003e\n\u003cp\u003eYes. The KN-COB-DP2 is UL 2034 listed, meeting the recognized U.S. standard for carbon monoxide alarms. It is compliant with NFPA 720 and the International Fire Code for use in commercial and residential occupancies.\u003c\/p\u003e\n\u003ch3\u003eWhat battery type is required for backup power?\u003c\/h3\u003e\n\u003cp\u003eThe KN-COB-DP2 uses a standard 9V battery for backup power. The battery is not included with the unit and should be installed at time of deployment. The unit's low battery indicator will alert users when the backup battery needs to be replaced.\u003c\/p\u003e\n\u003ch3\u003eDoes the KN-COB-DP2 support interconnect?\u003c\/h3\u003e\n\u003cp\u003eThe KN-COB-DP2 does not support interconnect. If your facility requires networked CO alarms that trigger simultaneously, consider the Kidde KN-COB-IC or KN-COP-IC hardwired interconnectable models available at WC Safety.\u003c\/p\u003e\n\u003ch3\u003eCan WC Safety fulfill bulk orders of the KN-COB-DP2 for hotel or property management programs?\u003c\/h3\u003e\n\u003cp\u003eYes. WC Safety supports bulk and volume purchasing for commercial customers including hotel chains, property management companies, and institutional safety programs. Contact us for quantity pricing, shipping logistics, and project procurement support.\u003c\/p\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":44089239306328,"sku":"KN-COB-DP2","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0594\/1900\/0920\/files\/31mXEemITDL._SL500.jpg?v=1778351932","url":"https:\/\/wcsafety.com\/products\/kidde-kn-cob-dp2-plug-in-carbon-monoxide-alarm-battery-backup-digital-display","provider":"WC Safety","version":"1.0","type":"link"}