Honeywell North 75SCP100L Multi-Contaminant P100 Respirator Cartridge
EDITORIAL REVIEW: 4.8/5 Independently reviewed by WC Safety "Editorial Pick β broadest North-line coverage at the lowest combination cartridge price" Read the full review β Β· 2026 Nort...
Check Price on Amazonπ Amazon Associate Β· You pay the same price Β· We earn a small commission
Honeywell North 75SCP100L β OV + Acid Gas + Ammonia + P100, NIOSH 42 CFR 84, WC Safety Editorial Pick
The Honeywell North 75SCP100L is a NIOSH 42 CFR 84 multi-contaminant P100 combination cartridge providing the broadest single-cartridge protection in the Honeywell North line: organic vapor, acid gas (HCl, HF, SOβ, Clβ, HβS), ammonia/methylamine, and 99.97% P100 particulate filtration β sold as a pair on the North bayonet system. It is WC Safety's Editorial Pick for the best-value cartridge in the North line, covering four hazard classes at a price at or below single-class alternatives. The 75SCP100L is the correct default when the hazard profile is not fully characterized by air monitoring, or when multiple gas classes are confirmed. For environments where particles are absent, the 75SCL gas-only Defender provides the same gas coverage at lower breathing resistance. Compatible with all North 7700, 5500, 5400, and 7600 series facepieces.
- Model: Honeywell North 75SCP100L
- Type: Multi-Contaminant P100 Combination Cartridge β sold as a pair
- NIOSH Approval: 42 CFR 84 OV + Acid Gas + Ammonia/MA + P100
- Gas Coverage: Organic vapor, HCl, HF, SOβ, Clβ, HβS, NHβ, methylamine
- Particle Coverage: P100 β 99.97% all particle types
- APF (Half-Mask): 10 on North 770030 and 550030 series
- APF (Full-Face): 50 on North 54001 and 760008 series
- Connector: North bayonet twist-lock
- WC Safety recommendation: Default choice for any multi-class or uncertain chemical hazard profile
Key Features
- WC Safety Editorial Pick: Broadest NIOSH-approved combination cartridge in the Honeywell North line β OV + acid gas + ammonia/MA + P100 in a single cartridge, typically priced at or below individual combination alternatives
- Four-class simultaneous protection: Organic vapor, acid gas (5 species), ammonia/methylamine, and P100 β eliminates the need to select between 7581P100L, 7582P100L, 7583P100L, and 7584P100L in environments where multiple classes may be present
- Correct default for uncertain environments: In facilities where the full chemical hazard profile has not been defined by comprehensive air monitoring, the 75SCP100L provides the broadest coverage available in the North line β reducing the risk of selecting an under-specified cartridge
- Sold as a pair: Two cartridges per package for both positions on a North facepiece
- Gas-only companion: The 75SCL Defender provides OV + AG + NHβ without P100 β use when the same broad gas coverage is needed but particles are formally confirmed absent
Applications β When to Use the 75SCP100L
The 75SCP100L is the default choice for multi-hazard industrial environments and for any situation where the full hazard profile is not fully characterized:
- Chemical plant and refinery maintenance: Turnaround work involving multiple chemical streams β OV (hydrocarbons), HβS, SOβ, and ammonia may all be co-present in the same operation
- Wastewater treatment plants: HβS, NHβ, and biological aerosol co-exposure β all covered by the 75SCP100L without needing to separate hazard classes
- Hazmat and emergency response: When the chemical composition of a release is unknown or mixed, the broadest available air-purifying protection is appropriate before supplied-air is donned
- Multi-process manufacturing: Facilities where workers rotate between solvent operations, acid processes, and ammonia-generating operations during the same shift
- Agriculture and confined space entry: Grain bins, manure pits, and mixed agricultural operations with OV, NHβ, and dust co-exposure
- Anywhere the hazard IH data is incomplete: When air monitoring has not been performed for all potential chemical classes, the 75SCP100L provides the broadest defensible coverage available in an air-purifying cartridge
Compatible Respirators
All Honeywell North 7-series and N-series cartridges use the North bayonet twist-lock connector, compatible with the following facepieces.
| Respirator | Type | APF | Notes |
|---|---|---|---|
| North 770030S | Half-Mask | 10 | Small |
| North 770030M | Half-Mask | 10 | Medium β start here if unsure of size |
| North 770030L | Half-Mask | 10 | Large |
| North 550030S | Half-Mask | 10 | Small β silicone facepiece |
| North 550030M | Half-Mask | 10 | Medium β silicone facepiece |
| North 550030L | Half-Mask | 10 | Large β silicone facepiece |
| North 54001S | Full-Face | 50 | Small β integrated eye protection |
| North 54001 | Full-Face | 50 | M/L β integrated eye protection |
| North 760008AS | Full-Face | 50 | Small β wide-view lens |
| North 760008A | Full-Face | 50 | M/L β wide-view lens |
North Cartridge & Filter Line β Full Comparison
All cartridges use the same North bayonet connector. Select based on documented hazard class.
| Model | Protection Class | Best For |
|---|---|---|
| P100 PARTICULATE FILTERS | ||
| 7580P100 | P100 β 99.97% | Silica, lead, asbestos, welding fume β particulate only (2-pack) |
| 75FFP100 | P100 β 99.97% | Same as 7580P100 β single unit |
| COMBINATION CARTRIDGES (GAS + P100) | ||
| 7581P100L | OV + P100 | Spray painting, solvents β OV and particles confirmed, no acid gas |
| 7582P100L | AG + P100 | HCl, HF, SOβ, Clβ, HβS β acid-only, OV formally excluded |
| 7583P100L | OV + AG + P100 | Mixed chemical environments β broader and cheaper than 7582P100L |
| 7584P100L | NHβ/MA + P100 | Wastewater, agriculture, refrigeration β ammonia primary hazard |
| 75SCP100L | OV + AG + NHβ + P100 | Multi-hazard / uncertain profile β broadest North-line coverage |
| 75852P100L | Mercury + Cl + P100 | Chlor-alkali, fluorescent lamp recycling β only North Hg cartridge |
| GAS-ONLY CARTRIDGES (NO P100) | ||
| N75001L | OV only | Pure vapor β no particles present |
| N75002L | OV + AG | Chemical work β no particles |
| N75003L | OV + AG + NHβ | Triple gas β wastewater, agriculture |
| N75004L | OV + NHβ | OV + ammonia β acid gas excluded |
| 75SCL | OV + AG + NHβ | Defender series β pure gas, lowest breathing resistance |
| SNAP-ON PREFILTERS | ||
| 7506N95 | N95 snap-on | Particle upgrade for gas cartridges β dry environments |
| 7506R95 | R95 snap-on | Oil mist / metalworking upgrade for gas cartridges |
| 7506N99 | N99 snap-on | Fine silica / pharma upgrade for gas cartridges |
| 7504R95 | R95 holder system | Oil mist β North cartridge holder format |
Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β
OSHA Compliance
- NIOSH approval required: All cartridges in OSHA-mandated programs must be NIOSH approved under 42 CFR Part 84
- Hazard assessment required: OSHA 1910.134(d)(1) β cartridge type must match the documented workplace hazard class
- Fit testing required: OSHA 1910.134(f)(2) β annual fit testing for any tight-fitting facepiece, regardless of cartridge type
- Cartridge change schedule: OSHA 1910.134(d)(3)(iii) β end-of-service-life for gas/vapor cartridges must be established before use
- Medical evaluation: OSHA 1910.134(e) β required before fit testing and before operational respirator use
Frequently Asked Questions
What does the 75SCP100L protect against?
Organic vapors, acid gases (HCl, HF, SOβ, Clβ, HβS), ammonia and methylamine, and P100 99.97% particle filtration β all simultaneously. The broadest NIOSH-approved combination in the North cartridge line. Does not cover mercury vapor (see 75852P100L) or carbon monoxide.
Why is the 75SCP100L the Editorial Pick?
It covers the most hazard classes of any North combination cartridge β OV + AG + NHβ + P100 β and is typically priced at or below single-class alternatives like the 7582P100L or 7584P100L. For any environment where the chemical profile includes more than one gas class, the 75SCP100L eliminates the risk of under-specifying. The only reasons to choose a narrower cartridge are confirmed absence of other classes (documented by air monitoring) or the need for lower breathing resistance when particles are absent.
Which respirators does the 75SCP100L fit?
All North bayonet facepieces: North 770030 series (S/M/L), North 550030 series (S/M/L), North 54001 and 54001S, North 760008A and 760008AS.
When should I use the 75SCL instead of the 75SCP100L?
Use the 75SCL when industrial hygiene assessment formally documents that no airborne particles are present in the work environment. The 75SCL provides the same OV + AG + NHβ gas coverage as the 75SCP100L but without the P100 layer β resulting in lower breathing resistance for pure-gas operations.
How do I set a change-out schedule for the 75SCP100L?
OSHA 1910.134(d)(3)(iii) requires a written change schedule established before use. For multi-class cartridges, the schedule is driven by the sorbent class with the shortest service life at the documented concentrations. Your industrial hygienist calculates this based on air monitoring data, contaminant concentration, temperature, humidity, and cartridge capacity. Do not rely on odor breakthrough as a warning signal.
Does the 75SCP100L cover welding fume?
Yes β the P100 component covers metal fume, and the OV sorbent covers solvent co-exposure from coatings. For stainless steel welding (Cr VI) or galvanized steel (zinc oxide), the P100 covers the particle hazard; confirm whether additional exposure controls are required for specific metal fume hazards under OSHA substance standards.
What is the APF of the 75SCP100L?
APF 10 on a half-mask. APF 50 on a full-face (North 54001, 760008A). APF applies per hazard class covered.
Does the 75SCP100L work for mercury?
No β mercury vapor requires a dedicated mercury-sorbent cartridge. The 75852P100L is the only North cartridge with NIOSH mercury vapor approval.
Is fit testing required?
Yes β OSHA 1910.134(f)(2). Annual fit testing for the facepiece before operational use.
Where can I find all North cartridges?
Browse the complete lineup at Honeywell North Respirator Cartridges & Filters β
Write a Review
Thank you for your review!
Your submission has been received and will be published after verification.