{"product_id":"gvs-elipse-ovag-p100-replacement-filters-fits-s-m-and-m-l-1-pair","title":"GVS Elipse OVAG P100 Replacement Filters — Fits S\/M and M\/L, 1 Pair","description":"\u003cdiv style=\"background:#2a2520;border-left:4px solid #ff9800;padding:18px 22px;margin:18px 0;color:#f5e6d3;font-family:Arial,sans-serif;\"\u003e\n\u003cstrong style=\"color:#ffb74d;\"\u003eDisclosures \u0026amp; editorial standards\u003c\/strong\u003e\u003cbr\u003eWC Safety participates in the Amazon Services LLC Associates Program. Outbound Amazon links are affiliate links. We accept no manufacturer payment, sponsorship, or product samples. \u003cstrong style=\"color:#ffffff;\"\u003eThis content is not medical, legal, or regulatory advice.\u003c\/strong\u003e Safety equipment selection is governed by applicable OSHA standards and your facility's safety program.\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#1a1a1a;color:#e0e0e0;font-family:Arial,sans-serif;padding:24px;max-width:900px;\"\u003e\n\n\u003ch2 style=\"color:#ff9800;font-size:1.6rem;margin-top:0;\"\u003eGVS Elipse OVAG P100 Replacement Filters — Both S\/M \u0026amp; M\/L, 1 Pair\u003c\/h2\u003e\n\n\u003cp\u003eThe GVS Elipse OVAG P100 is a third-generation multi-gas and dust replacement filter for \u003ca href=\"\/collections\/half-mask-respirators\" style=\"color:#4fc3f7;\"\u003eGVS Elipse and Integra Low Profile OVAG P100 half-face respirators\u003c\/a\u003e. Built on two GVS-patented technologies — \"Encapsulation\" of the HESPA filter media enabling a curved low-profile form factor, and graduated carbon that extends gas molecule adsorption path length through more adsorbent material — the result is a filter GVS states is 30% smaller in size and weight than conventional filters while delivering higher gas performance than standard carbon layer designs. Recommended for multi-gas and dust environments including all types of organic gases, inorganic gases, formaldehyde, chemical gases, and particulate dust. Note: ammonia is specifically excluded from the recommended application list — for ammonia environments, a cartridge with explicit ammonia NIOSH approval is required. Universal fit covers both Small\/Medium and Medium\/Large Elipse and Integra Low Profile facepieces. Sold as 1 pair (2 filters). Browse the full \u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003erespirator filters and cartridges\u003c\/a\u003e catalog at WC Safety.\u003c\/p\u003e\n\n\u003cp\u003eVendor: \u003cstrong\u003eGVS\u003c\/strong\u003e | Model: \u003cstrong\u003eOVAG P100\u003c\/strong\u003e | ASIN: \u003cstrong\u003eB0GGHVFRR2\u003c\/strong\u003e | EAN: \u003cstrong\u003e5060233805051\u003c\/strong\u003e | Pack: \u003cstrong\u003e1 Pair (2 filters)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.amazon.com\/dp\/B0GGHVFRR2?tag=wcsafety04-20\" style=\"color:#4fc3f7;\" target=\"_blank\" rel=\"nofollow\"\u003eBuy GVS OVAG P100 on Amazon ↗\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2 style=\"color:#ff9800;\"\u003eProtection Profile\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin-bottom:1.2rem;\"\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eHazard Class\u003c\/th\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eOVAG P100 Status\u003c\/th\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eOrganic gases and vapors (OV)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#4fc3f7;\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eSolvents, paints, adhesives, fuel vapors, chemical processing vapors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eInorganic gases\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#4fc3f7;\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eBroad inorganic gas coverage — see manufacturer specs for specific substances and concentrations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eFormaldehyde\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#4fc3f7;\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eHealthcare, laboratory, wood products, embalming, resin manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eChemical gases (general)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#4fc3f7;\"\u003eRecommended\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eChemical production and handling environments — verify specific substances with GVS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eP100 particulate and dust\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#4fc3f7;\"\u003eP100 — 99.97% efficiency, oil-proof\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eDust, fume, mist — all solid and liquid aerosols including oil-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#f44336;\"\u003eExcluded — not recommended\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eGVS explicitly excludes ammonia from the OVAG P100 application scope — use a cartridge with ammonia NIOSH approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.85rem;color:#aaa;\"\u003eGVS recommends this filter for chemical production and handling environments with multi-gas and dust risks. For compliance programs, confirm the specific substance and concentration against GVS's published filter specification and applicable NIOSH approval data. The APF is determined by the facepiece: APF 10 for a \u003ca href=\"\/collections\/half-mask-respirators\" style=\"color:#4fc3f7;\"\u003ehalf-face respirator\u003c\/a\u003e, APF 50 for a \u003ca href=\"\/collections\/full-face-mask-respirators\" style=\"color:#4fc3f7;\"\u003efull-face respirator\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color:#ff9800;\"\u003ePatented Third-Generation Filter Technologies\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin-bottom:1.2rem;\"\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#ff9800;width:36%;\"\u003e\u003cstrong\u003eEncapsulation of HESPA Filter Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eGVS's patented Encapsulation technology encases the HESPA (High-Efficiency Sub-micron Particulate Air) filter media in a curved, low-profile form factor while optimizing pleated dust filter resistance. This enables the OVAG P100 to maintain the Elipse platform's signature low-profile swept-back geometry — minimizing forward projection and improving field of view — without sacrificing filter media surface area or efficiency. The curved pleated design also distributes airflow more evenly across the media than flat panel alternatives, contributing to the stated lower breathing resistance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#ff9800;\"\u003e\u003cstrong\u003eGraduated Carbon Adsorption Layer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eThe graduated carbon design extends the path length that gas molecules travel through the activated carbon adsorbent, allowing more contact time between the gas molecule and the carbon surface. Standard flat carbon layer designs have a fixed path length that limits the quantity of adsorbent a gas molecule passes through. GVS's graduated approach maximizes gas performance compared to conventional filter elements — particularly relevant for heavier molecular weight organic vapors and chemical gases where carbon path length is a significant factor in adsorption effectiveness.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;color:#ff9800;\"\u003e\u003cstrong\u003e30% Smaller and Lighter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eGVS states the OVAG P100 is 30% smaller in size and weight compared to average filters in its performance class. In a half-face respirator context, smaller, lighter filter cartridges reduce the rotational moment on the facepiece during physical work, decreasing seal fatigue over long shift durations. The reduced bulk also improves compatibility with safety glasses, face shields, and welding visors by reducing the lateral protrusion that can conflict with other PPE components.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color:#ff9800;\"\u003eCompatible Facepieces\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin-bottom:1.2rem;\"\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eFacepiece Series\u003c\/th\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eSizes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003e\u003ca href=\"\/collections\/half-mask-respirators\" style=\"color:#4fc3f7;\"\u003eGVS Elipse Low Profile OVAG P100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eSmall\/Medium and Medium\/Large\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003e\u003ca href=\"\/collections\/half-mask-respirators\" style=\"color:#4fc3f7;\"\u003eGVS Integra Low Profile OVAG P100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eSmall\/Medium and Medium\/Large\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.85rem;color:#aaa;\"\u003eConfirm facepiece model compatibility against GVS's published documentation before use in a compliance program. OSHA 1910.134 requires manufacturer-confirmed facepiece and filter system compatibility. Not compatible with GVS Elipse SPR321 or SPR656\/657 series — those facepieces use different filter connections.\u003c\/p\u003e\n\n\u003ch2 style=\"color:#ff9800;\"\u003eGVS Elipse Filter Comparison\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;margin-bottom:1.2rem;\"\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eProtection\u003c\/th\u003e\n\u003cth style=\"padding:8px 12px;border:1px solid #333;text-align:left;color:#ff9800;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003e\u003cstrong\u003eOVAG P100 (this product)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eOV, inorganic gases, formaldehyde, chemical gases + P100 (excl. NH3)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eChemical production, multi-gas industrial, formaldehyde environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#2a2a2a;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003e\u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003eSPR658 OV\/P100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eOV + P100 (NIOSH TC-84A-9377)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003ePainting, solvents, pesticides, automotive, shipyard (Elipse SPR656\/657 facepiece)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003e\u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003eSPR450 P100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eP100 + nuisance odor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #333;\"\u003eWoodworking, sanding, construction dust where vapor compliance is not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color:#ff9800;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cdetails style=\"margin-bottom:10px;\"\u003e\u003csummary style=\"background:#2a2a2a;padding:10px 14px;cursor:pointer;color:#ff9800;border-radius:4px;\"\u003eWhy is ammonia excluded from the OVAG P100 application list?\u003c\/summary\u003e\n\u003cdiv style=\"background:#222;padding:12px 16px;border:1px solid #333;\"\u003eGVS explicitly states the OVAG P100 is recommended for multi-gas and dust risks excluding ammonia. Ammonia is a challenging gas for activated carbon adsorption — its low molecular weight and polarity require specialized adsorbents (often impregnated carbon or specific formulations) that standard activated carbon handles less effectively than heavier organic molecules. For ammonia environments, use a cartridge with explicit ammonia NIOSH approval (e.g., a multi-gas cartridge that lists NH3 in its NIOSH approval). Browse the \u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003erespirator filters and cartridges\u003c\/a\u003e collection for multi-gas options with NH3 coverage.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:10px;\"\u003e\u003csummary style=\"background:#2a2a2a;padding:10px 14px;cursor:pointer;color:#ff9800;border-radius:4px;\"\u003eWhat does \"graduated carbon\" mean compared to a standard carbon layer?\u003c\/summary\u003e\n\u003cdiv style=\"background:#222;padding:12px 16px;border:1px solid #333;\"\u003eA standard flat carbon layer presents a fixed bed depth that gas molecules pass through uniformly. GVS's graduated carbon design varies the carbon bed structure to extend the effective path length that gas molecules travel through adsorbent material — increasing contact time and the total volume of carbon each molecule encounters. This is analogous to comparing a shallow pool to a longer channel: the channel provides more opportunity for the gas to adsorb. GVS states this maximizes gas performance relative to conventional filter elements of similar size and weight. For users in chemical environments where gas breakthrough is a compliance-critical concern, longer carbon path length is a meaningful engineering difference.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:10px;\"\u003e\u003csummary style=\"background:#2a2a2a;padding:10px 14px;cursor:pointer;color:#ff9800;border-radius:4px;\"\u003eIs the OVAG P100 the same as the SPR658 OV\/P100?\u003c\/summary\u003e\n\u003cdiv style=\"background:#222;padding:12px 16px;border:1px solid #333;\"\u003eNo — they are different GVS filter products for different facepiece lines. The \u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003eSPR658\u003c\/a\u003e is for the Elipse SPR656\/657 and Integra SPR659\/660 facepieces, carries NIOSH approval TC-84A-9377 for OV + P100, and is recommended for painting, solvents, and pesticides. The OVAG P100 (this product) is for the Elipse OVAG P100 and Integra OVAG P100 facepiece series, uses GVS's third-generation patented filter design, and covers a broader multi-gas range (OV, inorganic, formaldehyde, chemical gases, excl. ammonia). The facepiece connection types differ — confirm your facepiece model before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:10px;\"\u003e\u003csummary style=\"background:#2a2a2a;padding:10px 14px;cursor:pointer;color:#ff9800;border-radius:4px;\"\u003eDoes the OVAG P100 fit both S\/M and M\/L Elipse sizes?\u003c\/summary\u003e\n\u003cdiv style=\"background:#222;padding:12px 16px;border:1px solid #333;\"\u003eYes — one OVAG P100 filter pair fits both Small\/Medium and Medium\/Large versions of the compatible \u003ca href=\"\/collections\/half-mask-respirators\" style=\"color:#4fc3f7;\"\u003eGVS Elipse OVAG P100 and Integra OVAG P100 facepieces\u003c\/a\u003e. Verify your facepiece model is in the compatible list before purchasing — the OVAG P100 filter does not fit the Elipse SPR321, SPR656, or SPR657 facepieces which use different filter connections.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:10px;\"\u003e\u003csummary style=\"background:#2a2a2a;padding:10px 14px;cursor:pointer;color:#ff9800;border-radius:4px;\"\u003eHow does a change-out schedule apply to the OVAG P100?\u003c\/summary\u003e\n\u003cdiv style=\"background:#222;padding:12px 16px;border:1px solid #333;\"\u003eOSHA 1910.134(d)(3)(iii) requires gas\/vapor cartridges without an ESLI to be replaced on a documented schedule before end of service life. Establish a change-out schedule using GVS's service life guidance for the OVAG P100, incorporating site-specific contaminant concentration, temperature, humidity, and breathing rate data for each substance present. The P100 particulate component has no time-based service life — replace when breathing resistance increases or damage occurs. Document the schedule in your written respiratory protection program. Browse \u003ca href=\"\/collections\/respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003erespirator filters and cartridges\u003c\/a\u003e for replacement pairs.\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"GVS","offers":[{"title":"Default Title","offer_id":44139687805016,"sku":"OVAG-P100","price":33.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0594\/1900\/0920\/files\/31c1-JxvRaL._SL500.jpg?v=1779675527","url":"https:\/\/wcsafety.com\/products\/gvs-elipse-ovag-p100-replacement-filters-fits-s-m-and-m-l-1-pair","provider":"WC Safety","version":"1.0","type":"link"}