{"product_id":"3m-6007-mercury-vapor-organic-vapor-acid-gas-respirator-cartridge","title":"3M 6007 Mercury Vapor \/ Organic Vapor \/ Acid Gas Respirator Cartridge","description":"\u003ch2 style=\"color:#e0e0e0;\"\u003e3M 6007 Mercury Vapor \/ Organic Vapor \/ Acid Gas Cartridge\u003c\/h2\u003e\n\u003cp style=\"color:#b0bec5;font-size:0.9em;\"\u003eNIOSH Approved · 3M Bayonet Connection · Gas \u0026amp; Vapor (no particulate filter) · Sold per pair\u003c\/p\u003e\n\u003cp style=\"color:#e0e0e0;\"\u003eThe \u003cstrong\u003e3M 6007\u003c\/strong\u003e is a NIOSH-approved gas and vapor cartridge built for one of the most demanding chemistries 3M offers — \u003cstrong\u003emercury vapor, chlorine, sulfur dioxide, organic vapor, and hydrogen sulfide\u003c\/strong\u003e. Its swept-back design widens the wearer's field of view and reduces bulk, while the universal \u003cstrong\u003e3M bayonet connection\u003c\/strong\u003e lets it twist onto 3M reusable half- and full-face respirators without adapters. For facilities that handle mercury, chlor-alkali processes, wastewater, or mixed acid-gas\/solvent exposures, the 6007 consolidates several hazards into a single cartridge and reduces inventory complexity.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eWhat the 6007 Protects Against\u003c\/h3\u003e\n\u003cul style=\"color:#e0e0e0;line-height:1.9;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMercury vapor\u003c\/strong\u003e — with an end-of-service-life indicator (ESLI) chemistry class\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChlorine \u0026amp; sulfur dioxide\u003c\/strong\u003e (acid gases)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrganic vapor\u003c\/strong\u003e — solvents and many hydrocarbons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHydrogen sulfide\u003c\/strong\u003e (escape applications per NIOSH)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"color:#e0e0e0;\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e the 6007 is a \u003cem\u003egas\/vapor cartridge only\u003c\/em\u003e — it does not filter particulates. If your job also produces dust, mist, or fume, add a \u003ca href=\"https:\/\/wcsafety.com\/products\/3m-2091-p100-respirator-filter\" style=\"color:#4fc3f7;\"\u003e3M 2091 P100 filter\u003c\/a\u003e, or step up to the combination \u003ca href=\"https:\/\/wcsafety.com\/products\/3m-60927-p100-mercury-vapor-organic-vapor-acid-gas-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003e3M 60927\u003c\/a\u003e, which adds a bonded P100 particulate filter to the same mercury\/OV\/acid-gas chemistry.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp style=\"color:#e0e0e0;\"\u003eMercury recovery and instrument repair, chlor-alkali plants, wastewater and water-treatment facilities, laboratories, and any operation with combined mercury-vapor and acid-gas or organic-vapor exposure confirmed by an OSHA exposure assessment.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eRespirator Compatibility\u003c\/h3\u003e\n\u003cp style=\"color:#e0e0e0;\"\u003eThe 3M bayonet mount fits the full range of 3M reusable respirators — the 6000, 6500\/6500QL, and 7500 half-masks, and the 6000 full-face, FF-400, and 7800 series. Browse the full bayonet range in \u003ca href=\"https:\/\/wcsafety.com\/collections\/3m-respirator-filters-and-cartridges\" style=\"color:#4fc3f7;\"\u003e3M Respirator Filters \u0026amp; Cartridges\u003c\/a\u003e. Not sure which cartridge you need? Use the \u003ca href=\"https:\/\/wcsafety.com\/blogs\/guides\/how-to-choose-a-respirator-cartridge\" style=\"color:#4fc3f7;\"\u003eCartridge Selection Guide\u003c\/a\u003e and the \u003ca href=\"https:\/\/wcsafety.com\/blogs\/guides\/3m-filter-cartridge-guide\" style=\"color:#4fc3f7;\"\u003ecomplete 3M Filter \u0026amp; Cartridge Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#ffb74d;\"\u003eColor Code \u0026amp; Change-Out\u003c\/h3\u003e\n\u003cp style=\"color:#e0e0e0;\"\u003eMulti-gas cartridges carry combination color bands under ANSI\/ISEA 110 (see the \u003ca href=\"https:\/\/wcsafety.com\/blogs\/reference\/respirator-cartridge-color-codes\" style=\"color:#4fc3f7;\"\u003ecartridge color code guide\u003c\/a\u003e). Mercury cartridges include an end-of-service-life indicator, but you must still follow a written change-out schedule under OSHA 1910.134(d)(3) — never rely on smell or taste. For particulate protection, also see the \u003ca href=\"https:\/\/wcsafety.com\/collections\/p100-respirator-filters\" style=\"color:#4fc3f7;\"\u003eP100 filters\u003c\/a\u003e collection.\u003c\/p\u003e\n\n\u003cp style=\"color:#9e9e9e;font-size:0.85em;\"\u003e\u003cem\u003eFor industrial\/occupational use only. Requires a medical evaluation, fit test, and written respiratory protection program per OSHA 29 CFR 1910.134. Final price set by Amazon and may vary.\u003c\/em\u003e\u003c\/p\u003e","brand":"3M","offers":[{"title":"Default Title","offer_id":44170866983000,"sku":null,"price":38.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0594\/1900\/0920\/files\/41f4Q-TZ6NL._SL500.jpg?v=1780429169","url":"https:\/\/wcsafety.com\/products\/3m-6007-mercury-vapor-organic-vapor-acid-gas-respirator-cartridge","provider":"WC Safety","version":"1.0","type":"link"}